Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Continuous detection of raised intraocular pressure (IOP) could benefit the monitoring of patients with glaucoma. Current contact lenses with embedded sensors for measuring IOP are rigid, bulky, partially block vision or are insufficiently sensitive. Here, we report the design and testing in volunteers of a soft and transparent contact lens for the quantitative monitoring of IOP in real time using a smartphone. The contact lens incorporates a strain sensor, a wireless antenna, capacitors, resistors, stretchable metal interconnects and an integrated circuit for wireless communication. In rabbits, the lens provided measurements that match those of a commercial tonometer. In ten human participants, the lens proved to be safe, and reliably provided accurate quantitative measurements of IOP without inducing inflammation.

Download full-text PDF

Source
http://dx.doi.org/10.1038/s41551-021-00719-8DOI Listing

Publication Analysis

Top Keywords

contact lens
12
soft transparent
8
transparent contact
8
quantitative monitoring
8
intraocular pressure
8
lens
5
contact
4
lens wireless
4
wireless quantitative
4
monitoring intraocular
4

Similar Publications

As emerging technologies reshape both the body and how we represent it, anatomical education stands at a threshold. Virtual dissection tools, AI-generated images, and immersive platforms are redefining how students learn anatomy, while real-world bodies are becoming hybridized through implants, neural interfaces, and bioengineered components. This Viewpoint explores what it means to teach human anatomy when the body is no longer entirely natural, and the image is no longer entirely real.

View Article and Find Full Text PDF

Scleral Lens and Suture Erosion in Scleral-Sutured Posterior Chamber Intraocular Lens.

Eye Contact Lens

September 2025

Department of Ophthalmology, Mayo Clinic Alix School of Medicine (H.P.N.), Mayo Clinic in Arizona, Scottsdale, AZ; and Department of Ophthalmology (O.M.H., D.R.P., E.R.K., J.F.S.), Mayo Clinic in Arizona, Scottsdale, AZ.

This case series reports two cases of scleral lens (SL)-associated suture erosion of polytetrafluoroethylene CV-8 (Gore-Tex, Newark, DE) in scleral-sutured CZ70BD (Alcon, Fort Worth, TX) posterior chamber intraocular lens (SS-PCIOL). Suture erosion after SS-PCIOL has been reported in two of the patients who were fitted with SL for visual acuity improvement. Erosion was corrected in both cases with suture repositioning and corneal patch graft, with one patient requiring the exchange of the intraocular lens.

View Article and Find Full Text PDF

Unlabelled: Contact lens wear in humans and mice is consistently associated with asymptomatic corneal parainflammation. Here, we tested the hypothesis that the corneal response to lens wear alone can function to protect it against bacterial adhesion enabled by superficial injury. One eye only of mT/mG-LysMcre mice (cell membranes red; Lyz2 cells green) wore a contact lens for 4-6 days.

View Article and Find Full Text PDF

A Clinical Evaluation of Lifitegrast Ophthalmic Solution 5% in Symptomatic Contact Lens Wearers.

Clin Ophthalmol

August 2025

Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, ON, Canada.

Purpose: To evaluate the effectiveness of lifitegrast ophthalmic solution 5% in alleviating end-of-day dryness and discomfort in symptomatic contact lens (CL) wearers.

Patients And Methods: This was an open-label study in symptomatic CL wearers with ratings of ≥40 for end-of-day dryness on a visual analog scale (VAS; 0-100 scale; 100 worst). Participants wore their habitual CLs and instilled lifitegrast twice daily for 12 weeks with lenses removed.

View Article and Find Full Text PDF

Purpose: This study aims to evaluate rotational stability and patient-reported outcomes associated with Tecnis Eyhance toric II "monofocal plus" intraocular lens (IOL), particularly in light of a modified haptic design.

Methods: A prospective, interventional study was conducted with patients undergoing routine cataract surgery and Tecnis Eyhance toric II IOL implantation. The inclusion criteria were topographic corneal astigmatism of 0.

View Article and Find Full Text PDF