Objective: We aimed to compare the aortic valve area (AVA) calculated using fast high-resolution three-dimensional (3D) magnetic resonance (MR) image acquisition with that of the conventional two-dimensional (2D) cine MR technique.
Materials And Methods: We included 139 consecutive patients (mean age ± standard deviation [SD], 68.5 ± 9.4 years) with aortic valvular stenosis (AS) and 21 asymptomatic controls (52.3 ± 14.2 years). High-resolution T2-prepared 3D steady-state free precession (SSFP) images (2.0 mm slice thickness, 10 contiguous slices) for 3D planimetry (3DP) were acquired with a single breath hold during mid-systole. 2D SSFP cine MR images (6.0 mm slice thickness) for 2D planimetry (2DP) were also obtained at three aortic valve levels. The calculations for the effective AVA based on the MR images were compared with the transthoracic echocardiographic (TTE) measurements using the continuity equation.
Results: The mean AVA ± SD derived by 3DP, 2DP, and TTE in the AS group were 0.81 ± 0.26 cm², 0.82 ± 0.34 cm², and 0.80 ± 0.26 cm², respectively ( = 0.366). The intra-observer agreement was higher for 3DP than 2DP in one observer: intraclass correlation coefficient (ICC) of 0.95 (95% confidence interval [CI], 0.94-0.97) and 0.87 (95% CI, 0.82-0.91), respectively, for observer 1 and 0.97 (95% CI, 0.96-0.98) and 0.98 (95% CI, 0.97-0.99), respectively, for observer 2. Inter-observer agreement was similar between 3DP and 2DP, with the ICC of 0.92 (95% CI, 0.89-0.94) and 0.91 (95% CI, 0.88-0.93), respectively. 3DP-derived AVA showed a slightly higher agreement with AVA measured by TTE than the 2DP-derived AVA, with the ICC of 0.87 (95% CI, 0.82-0.91) vs. 0.85 (95% CI, 0.79-0.89).
Conclusion: High-resolution 3D MR image acquisition, with single-breath-hold SSFP sequences, gave AVA measurement with low observer variability that correlated highly with those obtained by TTE.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8316769 | PMC |
http://dx.doi.org/10.3348/kjr.2020.1218 | DOI Listing |
Eur Heart J Case Rep
September 2025
Department of Cardiology, Toyohashi Heart Center, 21-1 Gobutori, Oyamacho, Toyohashi 441-8530, Japan.
Background: Mitral regurgitation (MR) may rarely worsen after transcatheter aortic valve implantation (TAVI) due to mechanical interference from the transcatheter heart valve (THV). Standard surgical approaches in these cases are often challenging due to anatomical constraints. Thus, there is a need for the development of effective alternatives to address this issue.
View Article and Find Full Text PDFRev Cardiovasc Med
August 2025
Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel, European Reference Networks Guard-Heart, 1090 Brussels, Belgium.
Despite continued advancements in transcatheter aortic valve implantation (TAVI) techniques, the incidence of permanent pacemaker implantation (PPI) remains substantial. Established predictors of PPI include advanced age, pre-existing electrocardiographic conduction abnormalities, prosthetic valve type, implantation depth, and anatomical parameters, such as membranous septum length, which are currently under active investigation. In routine clinical practice, the management strategy often involves the temporary placement of a transvenous pacemaker lead, followed by a period of observation.
View Article and Find Full Text PDFRev Cardiovasc Med
August 2025
Department of Cardiology, Harbin Medical University, 150000 Harbin, Heilongjiang, China.
Background: Differences between female and male patients may influence the outcomes of transcatheter aortic valve replacement (TAVR). However, knowledge regarding known sex differences in TAVR procedures among Chinese people remains limited. Therefore, this study aimed to investigate the impact of sex-related differences on reverse left ventricular (LV) remodeling following TAVR in the Chinese population.
View Article and Find Full Text PDFRev Cardiovasc Med
August 2025
E. Meshalkin National Medical Research Center, Institute of Cardiovascular Pathology Research, 630055 Novosibirsk, Russian Federation.
Background: Presently, the availability of single-stage surgical correction of mitral valve disease combined with atrial fibrillation (AF) via a mini-access approach remains limited. Moreover, the comparative effectiveness of this procedure versus conventional sternotomy (CS) remains poorly understood. Thus, this study aimed to conduct a comparative assessment of the efficacy and safety of concomitant mitral valve surgery and AF ablation via a minimally invasive approach (minimally invasive cardiac surgery, MICS group) versus the standard sternotomy approach (CS group).
View Article and Find Full Text PDFFront Cardiovasc Med
August 2025
Department of Cardiovascular Medicine, The First Hospital of Jilin University, Changchun, China.
Due to the low incidence of cardiovascular involvement in syphilis, there are currently no established consensus or guidelines for managing such cases. The patient, with no coronary artery disease risk factors, presented with chest pain and heart failure (HF). Emergency coronary angiography revealed severe stenosis of the bilateral coronary ostia, with smooth intimal lining in the remaining coronary arteries.
View Article and Find Full Text PDF