Investigation of echocardiographic characteristics and predictors for persistent defects of patent foramen ovale or patent ductus arteriosus in Chinese newborns.

Biomed J

Division of Cardiology, Department of Internal Medicine, Chang Gung Memorial Hospital at Kaohsiung, Kaohsiung, Taiwan; Center for Shockwave Medicine and Tissue Engineering, Department of Medical Research, Chang Gung Memorial Hospital at Kaohsiung, Kaohsiung, Taiwan; College of Medicine, Chang Gung U

Published: April 2021


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Persistent patent foramen ovale (PFO) and patent ductus arteriosus (PDA) increase the adult risk of cryptogenic embolic stroke and chronic pulmonary hypertension. To understand the characteristics of PFO and PDA in newborns, we investigated the spontaneous closure rate and derived the determinants for residual defects.

Methods: We utilized the database of congenital heart disease (CHD) in Xiamen ChangGung Memorial Hospital from 2015 to 2017 and allocated 2523 eligible newborns into four groups according to PDA, PFO, both or neither at birth. A total of 574, 1229, 202 and 518 newborns were assigned into the group of PFO and PDA, PFO alone, PDA alone and non-PFO/non-PDA, respectively. Regular echocardiographic follow-ups at baseline, 6, 12 and 24 months after birth were performed for evaluating the spontaneous closure rate in the subjects. Regression analysis was carried out to study the risk factors of residual congenital defects.

Results: Newborns with PFO alone had the youngest birth age and lowest birth weight among the four groups. About one in four PDA-alone newborns had concomitant small ASD, i.e., <5 mm in diameter. Echocardiographic study showed that 71.3% and 30.8% of CHD newborns had PFO and PDA, respectively, compared to less than 10% of them having ASD or VSD. However, more than 95% of newborns with PFO or PDA closed spontaneously at 6 months, in contrast to about 30% of newborns with ASD or VSD had persistent existence of the intracardiac defects. Complex CHD significantly linked to persistent PFO or PDA at 6 and 12 months, with an adjusted hazard ratio of 9.03 (95% CI 1.97-41.46) and 12.11 (95% CI 2.11-69.72), respectively.

Conclusions: Chinese newborns with PFO or PDA expressed differences in characteristics and concomitant congenital defects. Additionally, persistent PFO or PDA is strongly associated with complex CHD and requires long-term regular monitoring for future associated complications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8178580PMC
http://dx.doi.org/10.1016/j.bj.2019.12.007DOI Listing

Publication Analysis

Top Keywords

pfo pda
12
patent foramen
8
foramen ovale
8
patent ductus
8
ductus arteriosus
8
spontaneous closure
8
closure rate
8
pda pfo
8
newborns
6
pfo
6

Similar Publications

Diastolic dysfunction contributes significantly to respiratory instability in preterm infants but remains under-characterized during early postnatal transition. We aimed to evaluate the evolution of biventricular diastolic function during the first week of life in very low birth weight (VLBW) preterm infants. In this prospective observational study, 20 preterm infants (< 32 weeks gestation or < 1500 g) underwent serial echocardiograms at 24, 48, 72 h, and day 7.

View Article and Find Full Text PDF

Introduction: Neonates with dextro-transposition of the great arteries (d-TGA) require adequate mixing at the atrial level. Without this, they experience severe cyanosis, necessitating balloon atrial septostomy (BAS). Multiple studies have identified various fetal echocardiogram (FE) findings as risk factors for postnatal BAS.

View Article and Find Full Text PDF

Aims: Simple congenital heart diseases (CHD) are associated with various central nervous system diseases, including epilepsy. This study aimed to compare the risk of epilepsy in patients with different types of simple CHD.

Methods: In this prospective cohort study, from January 2008 to June 2022, patients with atrial septal defect (ASD), patent foramen ovale (PFO), ventricular septal defect (VSD), and patent ductus arteriosus (PDA) were recruited at the Registration Center of CHD in West China Hospital.

View Article and Find Full Text PDF

It was a rare case of a 52-year-old female with a slender PDA combined with PFO related to a transient ischemic attack that did not improve with aspirin and/or clopidogrel treatment. We closed the PDA using the ADO-II occluder and closed the PFO with the occluder, resulting in symptom resolution.

View Article and Find Full Text PDF

Background: Interventional cardiac catheterizations have gained major importance in the treatment of congenital heart defects (CHDs). Since patients with CHDs frequently require lifelong medical care and sometimes subsequent invasive treatment, repeated radiation exposure during interventional procedures is a relevant issue concerning potential radiation-related risks. Therefore, a 9-year subanalysis on radiation data during interventional cardiac catheterizations from the German Registry for Cardiac Operations and Interventions in patients with CHDs was performed.

View Article and Find Full Text PDF