Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

In this research, an efficient (94.9-99.4%) and fast (5 min) method has been developed and validated for simultaneous identification and quantification of phenolic endocrine disrupting compounds with an emphasis on bisphenol A (BPA) and 4-cumylphenol (4-CP) in food stuffs using a dual-template magnetic, molecularly-imprinted polymer (dt-MMIP). The dt-MMIP was synthesized by a sol-gel method using FeO@SiO (as the core) and BPA and 4-CP (as templates). The dt-MMIP was coupled with magnetic solid phase extraction to simultaneously detect BPA and 4-CP in food samples. BPA was measured from bottled water and fruit juice samples samples at 0.36 and 0.24 ng mL, respectively, while 4-CP in those samples was 0.33 and 0.16 ng mL, respectively. Their detection limits were estimated as 0.04 and 0.05 ng mL, respectively. The developed dt-MMIP method was highly reproducible, while maintaining a good cyclability up to 20 cycles.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.envpol.2021.116613DOI Listing

Publication Analysis

Top Keywords

dual-template magnetic
8
phenolic endocrine
8
endocrine disrupting
8
disrupting compounds
8
4-cp food
8
bpa 4-cp
8
magnetic molecularly
4
molecularly imprinted
4
imprinted polymer-based
4
polymer-based sorbent
4

Similar Publications

Dual-template magnetic molecularly imprinted polymers for selective extraction and sensitive detection of aflatoxin B1 and benzo(α)pyrene in environmental water and edible oil.

Food Chem

November 2024

Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Hubei Hongshan Laboratory, Key Laboratory of Biology and Genetic Improvement of Oil Crops, Key Laboratory of Detection for Mycotoxins, National Reference Lab for Biotoxin Test, Wuhan 430062, PR China; State Key Laboratory

The coexistence of multiple contaminates in the environment and food is of growing concern due to their extremely hazard as a well-known class I carcinogen, like aflatoxin B1 (AFB1) and benzo(α)pyrene (BaP). AFB1 and BaP are susceptible to coexistence in environmental water and edible oil, posing a significant potential risk to environmental monitoring and food safety. The remaining challenges in detecting multiple contaminates include unsatisfied sensitivity, insufficient targets selectivity, and interferences in complex matrices.

View Article and Find Full Text PDF

One-pot preparation of magnetic molecularly imprinted adsorbent with dual template molecules for simultaneously specific capture of sulfonamides and quinolones in water and milk samples.

Food Chem

February 2024

Fujian Provincial Key Laboratory for Coastal Ecology and Environmental Studies, College of the Environment and Ecology, Xiamen University, Xiamen 361005, China. Electronic address:

Specific capture is a beneficial tactic in simultaneous monitoring of sulfonamides (SAs) and quinolones (QLs). For this purpose, a new magnetic molecularly imprinted adsorbent based on double-template molecules (DT-MIP@MNA) was facilely prepared by "one-pot" hydrothermal technique and utilized as the adsorbent of magnetic solid-phase extraction (MSPE). Molecular simulation technique was employed to quickly screen functional monomer.

View Article and Find Full Text PDF

An eco-friendly magnetic dual-dummy-template molecularly imprinted polymer (MDDMIP) was prepared by a "one-pot" green synthesis using mixed-valence iron hydroxide as the magnetic material, a deep eutectic solvent as the coporogen, and caffeic acid and glutamic acid as binary monomers. The adsorption properties toward organophosphorus pesticides (OPPs) were investigated. High adsorption capacities (269.

View Article and Find Full Text PDF

Preparation and Application of a Magnetic Oxidized Micro/Mesoporous Carbon with Efficient Adsorption for Cu(II) and Pb(II).

Polymers (Basel)

November 2022

Shaanxi Key Laboratory of Comprehensive Utilization of Tailings Resources, Shaanxi Engineering Research Center for Mineral Resources Clean & Efficient Conversion and New Materials, Shangluo University, Shangluo 726000, China.

Water pollution is a worldwide problem that requires urgent attention and prevention and exceeding use of heavy-metal ions is one of the most harmful factors, which poses a serious threat to human health and the ecological environment. In this work, a magnetic oxidized micro/mesoporous carbon (MOMMC) was prepared for the easy separation of Cu(II) and Pb(II) from water. The dual-template method was used to prepare micro/mesoporous carbon using sucrose as the carbon source, silica nanoparticles formed by tetraethyl orthosilicate as the microporous templates, and triblock copolymer F127 as the mesoporous template.

View Article and Find Full Text PDF

A novel dual-template magnetic molecularly imprinted polymer (MMIP) was synthesized to extract normetanephrine (NMN), metanephrine (MN) and 3-methoxytyramine (3-MT) from spot urine samples. As the adsorbent of dispersive solid-phase extraction (d-SPE), the MMIP was prepared using dopamine and MN as dual templates, methacrylic acid as the functional monomer, ethylene glycol dimethacrylate as the crosslinking reagent and magnetic nanoparticles as the magnetic core. NMN, MN, 3-MT and creatinine (Cr) in spot urine samples were selectively enriched by d-SPE and detected by HPLC-fluorescence detection/ultraviolet detection.