Objective: To study the MiniMed Advanced Hybrid Closed-Loop (AHCL) system, which includes an algorithm with individualized basal target set points, automated correction bolus function, and improved Auto Mode stability.
Research Design And Methods: This dual-center, randomized, open-label, two-sequence crossover study in automated-insulin-delivery-naive participants with type 1 diabetes (aged 7-80 years) compared AHCL to sensor-augmented pump therapy with predictive low glucose management (SAP + PLGM). Each study phase was 4 weeks, preceded by a 2- to 4-week run-in and separated by a 2-week washout.
Results: The study was completed by 59 of 60 people (mean age 23.3 ± 14.4 years). Time in target range (TIR) 3.9-10 mmol/L (70-180 mg/dL) favored AHCL over SAP + PLGM (70.4 ± 8.1% vs. 57.9 ± 11.7%) by 12.5 ± 8.5% ( < 0.001), with greater improvement overnight (18.8 ± 12.9%, < 0.001). All age-groups (children [7-13 years], adolescents [14-21 years], and adults [>22 years]) demonstrated improvement, with adolescents showing the largest improvement (14.4 ± 8.4%). Mean sensor glucose (SG) at run-in was 9.3 ± 0.9 mmol/L (167 ± 16.2 mg/dL) and improved with AHCL (8.5 ± 0.7 mmol/L [153 ± 12.6 mg/dL], < 0.001), but deteriorated during PLGM (9.5 ± 1.1 mmol/L [17 ± 19.8 mg/dL], < 0.001). TIR was optimal when the algorithm set point was 5.6 mmol/L (100 mg/dL) compared with 6.7 mmol/L (120 mg/dL), 72.0 ± 7.9% vs. 64.6 ± 6.9%, respectively, with no additional hypoglycemia. Auto Mode was active 96.4 ± 4.0% of the time. The percentage of hypoglycemia at baseline (<3.9 mmol/L [70 mg/dL] and ≤3.0 mmol/L [54 mg/dL]) was 3.1 ± 2.1% and 0.5 ± 0.6%, respectively. During AHCL, the percentage time at <3.9 mmol/L (70 mg/dL) improved to 2.1 ± 1.4% ( = 0.034) and was statistically but not clinically reduced for ≤3.0 mmol/L (54 mg/dL) (0.5 ± 0.5%; = 0.025). There was one episode of mild diabetic ketoacidosis attributed to an infusion set failure in combination with an intercurrent illness, which occurred during the SAP + PLGM arm.
Conclusions: AHCL with automated correction bolus demonstrated significant improvement in glucose control compared with SAP + PLGM. A lower algorithm SG set point during AHCL resulted in greater TIR, with no increase in hypoglycemia.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2337/dc20-2250 | DOI Listing |
G Ital Nefrol
August 2025
Infermiere Professionale SSD Nefrologia e Dialisi P.O. Soverato, ASP CZ.
Management of diabetes mellitus in hemodialysis is highly complex due to increased glycemic variability and hypoglycemic risk. The use of technologies applied to diabetes has been shown to improve glycemic control, however data in dialysis patients are limited. To describe the efficacy and safety of the minimed 780G AHCL system in a stable hemodialysis patient and during hospitalization in the Intensive Care Unit (ICU).
View Article and Find Full Text PDFJCEM Case Rep
October 2025
Servicio de Endocrinología y Nutrición, Hospital Universitario Clínico San Carlos, Madrid 28040, Spain.
This case report describes a 25-year-old woman with type 1 diabetes mellitus (T1DM) and autoimmune thyroid disease (AITD) who developed Addison disease (AD). The diagnosis was suspected due to a significant decrease in insulin requirement and recurrent hypoglycemia despite adjustments in insulin pump therapy. The patient exhibited typical clinical features of AD, including hyperpigmentation and electrolyte imbalances.
View Article and Find Full Text PDFBMC Pediatr
September 2025
Department of Pediatrics, Faculty of Medicine, Cairo University, Cairo, Egypt.
Background: Structured diabetes education plays a crucial role in the management of Type 1 Diabetes (T1D), especially with advanced technologies such as continuous subcutaneous insulin infusion (CSII). This study evaluates the impact of tailored education on adherence and glycemic control among pediatric CSII users.
Patients And Methods: This interventional analytical study included 30 patients diagnosed with T1D with age ranged from 5 to 18 years, recruited from Diabetes & Endocrinology Clinic at tertiary university-based children's hospital.
Best Pract Res Clin Endocrinol Metab
August 2025
Clinical and Experimental Endocrinology, KU Leuven, Belgium; Department of Endocrinology, University Hospitals Leuven, Belgium. Electronic address:
Automated insulin delivery (AID) systems have led to a paradigm shift for the management of type 1 diabetes outside pregnancy. As more women use AID at preconception, it is important to have data on the efficacy and safety of AID systems in pregnancy. A large randomized controlled trial (RCT) with the CamAPS® FX showed a 10 % increase in time in range compared to standard insulin therapy in pregnant women with type 1 diabetes.
View Article and Find Full Text PDFDiabetes Technol Ther
August 2025
Medtronic, Northridge, California, USA.
The present study assessed the impact of the disposable Simplera Sync™ sensor with the MiniMed™ 780G (MM780G) advanced hybrid closed-loop (AHCL) system on type 1 diabetes (T1D) glycemic metrics, insulin delivery, and safety. Youths (aged 7-17 years) and adults (aged 18-80 years) with T1D were enrolled in this single-arm, nonrandomized study at 24 sites in the United States. Participants began with an ∼2-week run-in period where hybrid closed-loop (HCL; auto basal only) or open-loop insulin delivery was used, followed by an ∼3-month study period with AHCL activated.
View Article and Find Full Text PDF