98%
921
2 minutes
20
This study objectively evaluates the similarity between standard full-field digital mammograms and two-dimensional synthesized digital mammograms (2DSM) in a cohort of women undergoing mammography. Under an institutional review board-approved data collection protocol, we retrospectively analyzed 407 women with digital breast tomosynthesis (DBT) and full-field digital mammography (FFDM) examinations performed from September 1, 2014, through February 29, 2016. Both FFDM and 2DSM images were used for the analysis, and 3216 available craniocaudal (CC) and mediolateral oblique (MLO) view mammograms altogether were included in the dataset. We analyzed the mammograms using a fully automated algorithm that computes 152 structural similarity, texture, and mammographic density-based features. We trained and developed two different global mammographic image feature analysis-based breast cancer detection schemes for 2DSM and FFDM images, respectively. The highest structural similarity features were obtained on the coarse Weber Local Descriptor differential excitation texture feature component computed on the CC view images (0.8770) and MLO view images (0.8889). Although the coarse structures are similar, the global mammographic image feature-based cancer detection scheme trained on 2DSM images outperformed the corresponding scheme trained on FFDM images, with area under a receiver operating characteristic curve (AUC) = 0.878 ± 0.034 and 0.756 ± 0.052, respectively. Consequently, further investigation is required to examine whether DBT can replace FFDM as a standalone technique, especially for the development of automated objective-based methods.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s11517-021-02313-1 | DOI Listing |
Med Phys
September 2025
Department of Radiology, Stony Brook University, New York, USA.
Background: In contrast-enhanced digital mammography (CEDM) and contrast-enhanced digital breast tomosynthesis (CEDBT), low-energy (LE) and high-energy (HE) images are acquired after injection of iodine contrast agent. Weighted subtraction is then applied to generate dual-energy (DE) images, where normal breast tissues are suppressed, leaving iodinated objects enhanced. Currently, clinical systems employ a dual-shot (DS) method, where LE and HE images are acquired with two separate exposures.
View Article and Find Full Text PDFIEEE Trans Med Imaging
September 2025
Mammography is a primary method for early screening, and developing deep learning-based computer-aided systems is of great significance. However, current deep learning models typically treat each image as an independent entity for diagnosis, rather than integrating images from multiple views to diagnose the patient. These methods do not fully consider and address the complex interactions between different views, resulting in poor diagnostic performance and interpretability.
View Article and Find Full Text PDFRadiology
September 2025
Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul 06351, Korea.
Background The optimal surgical management of human epidermal growth factor receptor 2 (HER2)-positive breast cancer with calcifications remains controversial, particularly when pathologic complete response (pCR) is suspected. Purpose To identify factors associated with pCR after neoadjuvant chemotherapy in patients with HER2-positive breast cancer and assess whether calcifications affect the performance of radiologic complete response (rCR) at MRI for predicting pCR. Materials and Methods This retrospective study included patients with HER2-positive breast cancer who received neoadjuvant docetaxel, carboplatin, trastuzumab, and pertuzumab and underwent surgery between January 2021 and October 2023.
View Article and Find Full Text PDFDigit Health
September 2025
Department of Respiratory and Critical Care Medicine, The Sixth Affiliated Hospital of Xinjiang Medical University, Urumqi, China.
Objective: Accurate segmentation of breast lesions, especially small ones, remains challenging in digital mammography due to complex anatomical structures and low-contrast boundaries. This study proposes DVF-YOLO-Seg, a two-stage segmentation framework designed to improve feature extraction and enhance small-lesion detection performance in mammographic images.
Methods: The proposed method integrates an enhanced YOLOv10-based detection module with a segmentation stage based on the Visual Reference Prompt Segment Anything Model (VRP-SAM).
Int J Cancer
September 2025
Karkinos Healthcare, Kerala Operations, Ernakulam, Kerala, India.
Clinical breast examination (CBE) is the only feasible option for the low- and middle-income countries that have the rising burden of breast cancers but lack adequate infrastructure and human resources for organised mammography screening programmes. However, CBE is a subjective test and this warrants evaluation of alternatives to CBE. We conducted a cross-sectional study to evaluate the agreement between iBreastExam (iBE) and CBE for early detection of breast cancers.
View Article and Find Full Text PDF