A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Carbon aerogel as a solid-phase microextraction fiber coating for the extraction and detection of trace tetracycline residues in food by coupling with high-performance liquid chromatography. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

A direct immersion solid-phase microextraction method for determining tetracyclines (TCs) was developed by coupling with high-performance liquid chromatography. A carbon aerogel (CA) was synthesized as a fiber coating with high extractive properties and a low density of 0.1855 g cm-3via ambient pressure drying and carbonization. The as-synthesized CA exhibited a high specific surface area and a cross-linked structure; it was characterized via scanning electron microscopy, transmission electron microscopy, Fourier transform infrared spectroscopy and Brunauer-Emmett-Teller analysis, etc. The extraction performance for six TCs was investigated, and the main experimental parameters were optimized by the Box-Behnken design. Adsorption kinetics, Langmuir and Freundlich models were used to clarify the extraction mechanism. This method showed wide linear ranges of 1-500 μg L-1, low limits of detection of 0.52-1.05 μg L-1, good repeatability of 1.37-12.47%, and satisfactory inter-fiber reproducibility of 8.51-15.81% relative standard deviation for the detection of six TCs. Moreover, this study provided an interesting insight into the detection of TCs residues in food samples.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d0ay02140gDOI Listing

Publication Analysis

Top Keywords

carbon aerogel
8
solid-phase microextraction
8
fiber coating
8
residues food
8
coupling high-performance
8
high-performance liquid
8
liquid chromatography
8
electron microscopy
8
μg l-1
8
detection tcs
8

Similar Publications