A multi-class scoring system based on CT features for preoperative prediction in gastric gastrointestinal stromal tumors.

Am J Cancer Res

Department of Radiology, Second Affiliated Hospital, School of Medicine, Zhejiang University 88 Jiefang Road, Hangzhou 310009, Zhejiang Province, China.

Published: November 2020


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Our study aimed to establish and validate a multi-class scoring system for preoperative gastric gastrointestinal stromal tumors (GISTs) risk stratifications based on CT features. 150 gastric GIST patients who underwent contrast-enhanced CT examination and surgical resection from hospital 1 were retrospectively analyzed as the training cohort, and 61 patients from hospitals 2 and 3 were included as the validation cohort. A model was established by logistic regression analysis and weighted to be a scoring model. A calibration test, area under the receiver operating characteristic (ROC) curve (AUC), and cutoff points were determined for the score model. The model was also divided into three score ranges for convenient clinical evaluation. Five CT features were included in the score model, including tumor size (4 points), ill-defined margin (6 points), intratumoral enlarged vessels (5 points), heterogeneous enhancement pattern (4 points), and exophytic or mixed growth pattern (2 points). Then, based on the calibration results, performance was merely assessed as very low and high* risk. The AUCs of the score model for very low risk and high* risk were 0.973 and 0.977, and the cutoff points were 3 points (97.30%, 93.81%) and 7 points (92.19%, 94.19%), respectively. In the validation cohort, the AUCs were 0.912 and 0.972, and the cutoff values were 3 points (92.31%, 85.42%) and 5 points (100%, 87.88%), respectively. The model was stratified into 3 ranges: 0-3 points for very low risk, 4-8 points for low risk, and 9-21 points for high* risk. A concise and practical score system for gastric GISTs risk stratification was proposed.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7716157PMC

Publication Analysis

Top Keywords

points
14
score model
12
high* risk
12
low risk
12
multi-class scoring
8
scoring system
8
based features
8
gastric gastrointestinal
8
gastrointestinal stromal
8
stromal tumors
8

Similar Publications

Objective: To develop and implement a method for determining the postmortem interval and the marginal errors of its estimates under conditions of linearly varying external temperature in the format of an online application.

Material And Methods: A computer-assissted numerical search for the absolute minimum point of the objective function obtained from a system of nonlinear equations reflecting the results of double rectal or cranioencephalic thermometry of a corpse under conditions of linearly varying external temperature was carried out. The search algorithm was generalized to possible marginal errors in measuring the initial indicators of temperature and time.

View Article and Find Full Text PDF

Cardiovascular diseases (CVDs) remain a leading cause of death, particularly in developing countries, where their incidence continues to rise. Traditional CVD diagnostic methods are often time-consuming and inconvenient, necessitating more efficient alternatives. Rapid and accurate measurement of cardiac biomarkers released into body fluids is critical for early detection, timely intervention, and improved patient outcomes.

View Article and Find Full Text PDF

BackgroundAlzheimer's disease (AD) is the most common neurodegenerative disorder. While AD diagnosis traditionally relies on clinical criteria, recent trends favor a precise biological definition. Existing biomarkers efficiently detect AD pathology but inadequately reflect the extent of cognitive impairment or disease heterogeneity.

View Article and Find Full Text PDF

Prolonging All-Optical Molecular Electron Spin Coherence in the Tissue Transparency Window.

J Am Chem Soc

September 2025

Division of Chemistry and Chemical Engineering, Arthur Amos Noyes Laboratory of Chemical Physics, California Institute of Technology, Pasadena, California 91125, United States.

Coherent electron spin states within paramagnetic molecules hold significant potential for microscopic quantum sensing. However, all-optical coherence measurements amenable to high spatial and temporal resolution under ambient conditions remain a significant challenge. Here we conduct room-temperature, picosecond time-resolved Faraday ellipticity/rotation (TRFE/R) measurements of the electron spin decoherence time in [IrBr].

View Article and Find Full Text PDF

Importance: Consumer wearable technologies have wide applications, including some that have US Food and Drug Administration clearance for health-related notifications. While wearable technologies may have premarket testing, validation, and safety evaluation as part of a regulatory authorization process, information on their postmarket use remains limited. The Stanford Center for Digital Health organized 2 pan-stakeholder think tank meetings to develop an organizing concept for empirical research on the postmarket evaluation of consumer-facing wearables.

View Article and Find Full Text PDF