98%
921
2 minutes
20
Background: Glycated haemoglobin A1c (HbA1c) has limitations as a glycemic marker for patients with diabetes and CKD and for those receiving dialysis. Glycated albumin is an alternative glycemic marker, and some studies have found that glycated albumin more accurately reflects glycemic control than HbA1c in these groups. However, several factors are known to influence the value of glycated albumin including proteinuria. Continuous glucose monitoring (CGM) is another alternative to HbA1c. CGM allows one to assess mean glucose, glucose variability, and the time spent in hypo-, normo-, and hyperglycemia. Currently, several different CGM models are approved for use in patients receiving dialysis; CKD (not on dialysis) is not a contraindication in any of these models. Some devices are for blind recording, while others provide real-time data to patients. Small studies suggest that CGM could improve glycemic control in hemodialysis patients, but this has not been studied for individual CKD stages.
Summary: Glycated albumin and CGM avoid the pitfalls of HbA1c in CKD and dialysis populations. However, the value of glycated albumin may be affected by several factors. CGM provides a precise estimation of the mean glucose. Here, we discuss the strengths and limitations for using HbA1c, glycated albumin, or CGM in CKD and dialysis population. Key Messages: Glycated albumin is an alternative glycemic marker but is affected by proteinuria. CGM provides a precise estimation of mean glucose and glucose variability. It remains unclear if CGM improves glycemic control in the CKD and dialysis populations.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1159/000511614 | DOI Listing |
PLoS One
September 2025
Department of Medicine, Faculty of Medicine, Universiti Malaya, Kuala Lumpur, Malaysia.
There is a lack of longitudinal data on type 2 diabetes (T2D) in low- and middle-income countries. We leveraged the electronic health records (EHR) system of a publicly funded academic institution to establish a retrospective cohort with longitudinal data to facilitate benchmarking, surveillance, and resource planning of a multi-ethnic T2D population in Malaysia. This cohort included 15,702 adults aged ≥ 18 years with T2D who received outpatient care (January 2002-December 2020) from Universiti Malaya Medical Centre (UMMC), Kuala Lumpur, Malaysia.
View Article and Find Full Text PDFEndocrine
September 2025
Section of Endocrinology, Geriatrics and Internal Medicine, Department of Medical Sciences, University of Ferrara, Ferrara, Italy.
Front Immunol
September 2025
Department of Rheumatology and Immunology, The First Hospital of China Medical University, China Medical University, Shenyang, Liaoning, China.
CAR-T cell therapy has been proven effective in various autoimmune diseases, with most studies utilizing lentiviral-transduced CAR-T cells. In recent years, retroviral vector-transduced CAR-T cells-characterized by a high positivity rate, stable cell lines, and lower plasmid requirements-have attracted increasing attention. This article presents a complex case of a patient with SLE combined with APS and TBIRS.
View Article and Find Full Text PDFEur J Clin Pharmacol
September 2025
Department of Pharmacy Practice, Saveetha College of Pharmacy, Saveetha Institute of Medical and Technical Sciences (SIMATS), Thandalam, Chennai, India.
Background: The prevalence of diabetes mellitus has surged fourfold globally over the past 30Â years, creating a major health concern. Imeglimin, a novel oral antidiabetic agent, has shown promising results in the management of type 2 diabetes mellitus (T2DM).
Objectives: This systematic review aimed to evaluate the efficacy and safety of imeglimin in patients with T2DM based on available clinical studies.
J Diabetes Sci Technol
September 2025
Guy's and St Thomas NHS Foundation Trust, Guy's Hospital, London, UK.
Aim: This review aims to map the existing literature on the use of diabetes technology in people receiving dialysis, with a focus on utilization, accuracy, and effectiveness.
Methods: A scoping review was conducted using the Joanna Briggs Institute methodology, with systematic searches of Medline, Embase, and CINAHL for studies on diabetes technologies in dialysis populations.
Results: The search identified 1060 continuous glucose monitoring (CGM) and 1467 continuous subcutaneous insulin infusion or automated insulin delivery (CSII/AID) records, with 64 studies included.