A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Distribution and emissions of trace elements in coal-fired power plants after ultra-low emission retrofitting. | LitMetric

Distribution and emissions of trace elements in coal-fired power plants after ultra-low emission retrofitting.

Sci Total Environ

State Key Joint Laboratory of Environmental Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing 100084, China.

Published: February 2021


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Various hazardous trace elements emitted from anthropogenic activities are attracting increasing public awareness. This study comprehensively explored the distribution and emissions of trace elements in coal-fired power plants (CFPPs) after ultra-low emission retrofitting by conducting field experiments, literature surveys, and model calculations. High levels of volatile Hg and semi-volatile As/Pb were mainly observed in fly ash and gypsum (96.6%-98.5%), while the proportion of non-volatile Cr in bottom ash was 9.23%. The Hg and As/Pb removal efficiencies were remarkably improved by ultra-low emission retrofitting, increasing by 5.67% and 2.08%/2.63%, respectively. However, ULE retrofitting only slightly affected (0.17%) non-volatile elements. These improvements were mainly attributed to the low-low-temperature electrostatic precipitator. Owing to the enhanced particle-capturing efficiencies, the concentrations of trace elements in the emitted gas of the tested CFPPs were low, ranging from 0.21-1.50 μg/m, but accounted for a high proportion of the gas phase (61.8%-100%). Based on the national database of coal quality and their behaviour in CFPPs, we found that most of the concentrations of trace elements emitted from Chinese CFPPs were significantly lower than the internationally existing emission limits. However, owing to the skewed distribution characteristics of the emitted concentrations, we suggest issuing or revising the corresponding emission limits and improving the control of intense trace element pollution in China.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.scitotenv.2020.142285DOI Listing

Publication Analysis

Top Keywords

trace elements
20
ultra-low emission
12
emission retrofitting
12
elements emitted
12
distribution emissions
8
emissions trace
8
elements coal-fired
8
coal-fired power
8
power plants
8
concentrations trace
8

Similar Publications