Article Abstract

Background & Aims: Although current quality indicators of colonoscopy recommend 6 minutes as the minimum standard for withdrawal time (WT), the impact of a WT longer than 6 minutes on neoplasia detection is unclear.

Methods: A multicenter randomized controlled trial involving 1027 patients was conducted from January 2018 to July 2019. Participants were randomly divided into a 9-minute (n = 514) and 6-minute (n = 513) WT group, and a timer was used to adjust the withdrawal speed. The primary outcome was the adenoma detection rate (ADR).

Results: Intention-to-treat analysis showed a significantly higher ADR in the 9-minute versus 6-minute WT group (36.6% vs. 27.1%, P = .001). Prolonging WT from 6 to 9 minutes significantly increased ADR of the proximal colon (21.4% vs. 11.9%, P < .001) as well as of the less experienced colonoscopists (36.8% vs. 23.5%, P = .001). Improvements were also observed in the polyp detection rate (58.0% vs. 47.8%, P < .001), and mean number of polyps and adenomas detected per colonoscopy (1.1 vs. 0.9, P = .002; 0.5 vs. 0.4, P = .008, respectively). The higher ADRs in 9-minute WT were also confirmed by the per-protocol (PP) analysis and subgroup analyses, with an increased rate of sessile serrated lesion detection in the 9-minute WT by PP analysis (4.0% vs. 1.3%, P = .04). Multivariate logistic regression demonstrated that the 9-minute WT was independently associated with increased ADR (P = .005).

Conclusions: Prolonging WT from 6 to 9 minutes significantly improved ADR, especially in the proximal colon and for less experienced colonoscopists. A 9-minute WT benchmark should be considered as one of the quality indicators of colonoscopy. ClinicalTrials.gov (identifier, NCT03399045).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cgh.2020.11.019DOI Listing

Publication Analysis

Top Keywords

detection rate
12
withdrawal time
8
adenoma detection
8
multicenter randomized
8
randomized controlled
8
controlled trial
8
quality indicators
8
indicators colonoscopy
8
prolonging minutes
8
increased adr
8

Similar Publications

Background: On September 27, 2024, Rwanda reported an outbreak of Marburg virus disease (MVD), after a cluster of cases of viral hemorrhagic fever was detected at two urban hospitals.

Methods: We report key aspects of the epidemiology, clinical manifestations, and treatment of MVD during this outbreak, as well as the overall response to the outbreak. We performed a retrospective epidemiologic and clinical analysis of data compiled across all pillars of the outbreak response and a case-series analysis to characterize clinical features, disease progression, and outcomes among patients who received supportive care and investigational therapeutic agents.

View Article and Find Full Text PDF

Purpose: The monotonous lighting environment in extra-long tunnels often induces mind-wandering in drivers. To address this issue, this study explores effective strategies to optimize tunnel lighting environments by configuring various background colors and special lighting zones to enhance the alertness of young drivers and ensure driving safety.

Methods: A virtual driving simulator was utilized to carry out the experiment.

View Article and Find Full Text PDF

Objective: To analyze the temporal trend of dengue incidence and lethality rates and the proportions of its serotypes, in the different macro-regions of Brazil, between 2001 and 2022. In particular, the immediate and gradual effects of these indicators were verified in the periods before and after the publication of the National Guidelines for the Prevention and Control of Dengue Epidemics.

Methods: This was an interrupted time series analysis.

View Article and Find Full Text PDF

Skin-adaptive focused flexible micromachined ultrasound transducers for wearable cardiovascular health monitoring.

Sci Adv

September 2025

State Key Laboratory for Manufacturing System Engineering, State Industry-Education Integration Center for Medical Innovations, International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technologies, Shaanxi Innovation Center for Special Sensing and Testing Technology in Extreme En

Continuous monitoring of cardiovascular vital signs can reduce the incidence and mortality of cardiovascular diseases, yet cannot be implemented by current technologies because of device bulkiness and rigidity. Here, we report self-adhesive and skin-conformal ultrasonic transducer arrays that enable wearable monitoring of multiple hemodynamic parameters without interfering with daily activities. A skin-adaptive focused ultrasound method with rational array design is proposed to implement measurement under wide ranges of skin curvatures and depths with improved sensing performances.

View Article and Find Full Text PDF

Background: The potential for racial disparity using urine drug screening (UDS) in patients with seizures is sparsely reported. This study aims to determine racial and ethnic disparities when ordering UDS in patients with suspected seizures in the emergency department (ED).

Methods: In this retrospective study, we identified patients over the age of 18 with suspected seizures who presented to the ED at the University of Kansas Medical Center between October 2017 and October 2020.

View Article and Find Full Text PDF