Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Since 2003, US hypertension guidelines have recommended ACE (angiotensin-converting enzyme) inhibitors or ARBs (angiotensin receptor blockers) as first-line antihypertensive therapy in the presence of albuminuria (urine albumin/creatinine ratio ≥300 mg/g). To examine national trends in guideline-concordant ACE inhibitor/ARB utilization, we studied adults participating in the National Health and Nutrition Examination Surveys 2001 to 2018 with hypertension (defined by self-report of high blood pressure, systolic blood pressure ≥140 mm Hg or diastolic ≥90 mm Hg, or use of antihypertensive medications). Among 20 538 included adults, the prevalence of albuminuria ≥300 mg/g was 2.8% in 2001 to 2006, 2.8% in 2007 to 2012, and 3.2% in 2013 to 2018. Among those with albuminuria ≥300 mg/g, no consistent trends were observed for the proportion receiving ACE inhibitor/ARB treatment from 2001 to 2018 among persons with diabetes, without diabetes, or overall. In 2013 to 2018, ACE inhibitor/ARB usage in the setting of albuminuria ≥300 mg/g was 55.3% (95% CI, 46.8%-63.6%) among adults with diabetes and 33.4% (95% CI, 23.1%-45.5%) among those without diabetes. Based on US population counts, these estimates represent 1.6 million adults with albuminuria ≥300 mg/g currently not receiving ACE inhibitor/ARB therapy, nearly half of whom do not have diabetes. ACE inhibitor/ARB underutilization represents a significant gap in preventive care delivery for adults with hypertension and albuminuria that has not substantially changed over time.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7725867PMC
http://dx.doi.org/10.1161/HYPERTENSIONAHA.120.16281DOI Listing

Publication Analysis

Top Keywords

≥300 mg/g
20
ace inhibitor/arb
20
albuminuria ≥300
16
angiotensin-converting enzyme
8
angiotensin receptor
8
adults albuminuria
8
2001 2018
8
blood pressure
8
2013 2018
8
receiving ace
8

Similar Publications

Introduction: Cirrhosis progresses from compensated to decompensated phases, often marked by portal hypertension and complications like ascites, variceal hemorrhage, and hepatic encephalopathy. The ammonia-to-urea (A-to-U) ratio, reflecting urea cycle efficiency, may offer superior diagnostic performance compared to plasma ammonia levels alone. This study compared the diagnostic accuracy of the A-to-U ratio and plasma ammonia levels for identifying portal hypertension.

View Article and Find Full Text PDF

A pseudo-hard-template, obtained by the self-assembly and disassembly of Victoria Pure Blue (VPB), was rationally designed to synthesize C-SiO hollow nanostructures (h-C-SiO). The hollow nanostructures show unprecedented perfluorooctanoic acid (PFOA) removal performance with an adsorption capacity of 790.71 mg g and fast adsorption kinetics of 4899.

View Article and Find Full Text PDF

Sodium-glucose cotransporter 2 inhibitors reduced proteinuria in patients with IgA nephropathy; however, their efficacy in patients at high risk of progression receiving immunosuppressive agents and renin angiotensin-aldosterone system inhibitors remains unclear. After 3 months of low-dose steroid alone or combined with mycophenolate mofetil, as well as renin angiotensin-aldosterone system inhibitors treatment, 105 biopsy-proven IgA nephropathy patients with proteinuria greater than 0.5 g/d were included in this study.

View Article and Find Full Text PDF

This study quantitatively evaluated the adsorption performance of natural bentonite for removing three dye classes-cationic (Basic dye: BEZACRYL RED GRL), anionic (Reactive dye: AVITERA LIGHT RED SE), and non-ionic (Disperse dye: BEMACRON BLUE HP3R) from synthetic textile wastewater. Batch adsorption experiments were conducted under varying conditions of contact time (15-90 min), adsorbent dosage (20-60 g L⁻), pH (4 and 12), and temperature (25-100 °C), with dye concentrations quantified by UV-Vis spectroscopy. At a contact time of 30 min and room temperature (25 °C), maximum removal efficiencies reached 99.

View Article and Find Full Text PDF

Lignin-intercalated WS with synergistic adsorption for efficiency lead removal.

Bioresour Technol

September 2025

School of Agricultural Engineering and Food Science, Shandong University of Technology, Zibo 255000, China; Zibo Engineering Research Center for Bio-based New Materials, Zibo 255000, China. Electronic address:

Tungsten disulfide (WS), a two-dimensional adsorbent material, has garnered great attention in removing lead ions (Pb) from water due to their extensive exposed adsorption sites. However, WS nanosheets inevitably agglomerated and stacked during the preparation and adsorption process, leading to reduced adsorption efficiency. Current method of enhancing WS dispersion is mainly blending with synthetic polymers, but these synthetic polymers themselves do not possess adsorption properties, resulting adsorption effect enhancement poorly.

View Article and Find Full Text PDF