Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: To compare the safety and accuracy of the 3D-printed operation guide template technique and the free-hand technique in the placement of the S2-alar-iliac (S2AI) screw.

Methods: We conducted a retrospective analysis of 47 patients undergoing S2AI screw placement in our hospital, divided into the 3D-printed operation guide template group and the free-hand screw placement group. The duration of single S2AI screw placement was documented in all patients. A postoperative CT scan was performed to assess screw placement effectiveness according to the distance from the screw tip to the breach of the cortical bone wall.

Results: In total, 42 screws were placed in the guide template group, with an average screw placement duration of 151.6 ± 44.8 s. Screw placement grading was as follows: 40 screws in grade 0, two in grade 1, and none in grades 2 and 3. This grading resulted in excellent and good rates of 95.2% and 100%, respectively. In total, 52 screws were placed in the free-hand group, with an average screw placement duration of 138.3 ± 45.9 s. Screw placement grading was as follows: 42 screws in grade 0, seven in grade 1, three in grade 2, and none in grade 3. This grading resulted in excellent, good and acceptable rates 80.8%, 94.2% and 100%, respectively. Screw placement duration did not significantly differ between the groups (p > 0.05). The excellent rate of screw placement was greater in the guide template group than in the free-hand group (p < 0.05), but the good and acceptable rates did not significantly differ between the two groups (p > 0.05).

Conclusion: Both techniques can be applied to S2AI screw placement. The 3D-printed guide technique is superior to the free-hand technique in terms of safety and accuracy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7596934PMC
http://dx.doi.org/10.1186/s12893-020-00930-5DOI Listing

Publication Analysis

Top Keywords

screw placement
48
guide template
20
screw
13
placement
13
3d-printed operation
12
operation guide
12
free-hand technique
12
s2ai screw
12
template group
12
placement duration
12

Similar Publications

Background:  Gradual correction of lower-limb angular deformities using external fixators such as the Taylor Spatial Frame (TSF) is a well-established technique for addressing complex, multiplanar deformities. A common yet understudied adjunct to this method is the use of a distal tibio-fibular syndesmotic screw to stabilize the ankle mortise during correction. Despite being frequently practiced, the necessity and efficacy of this intervention remain unclear.

View Article and Find Full Text PDF

The cervicothoracic junction (CTJ) presents a surgical challenge due to its transitional nature from mobile to rigid segments. Therefore, the biomechanical characteristics of this transitional zone must be taken into consideration during instrumentation. This study aimed to determine the efficacy of the cervical pedicle screw placement (CPS) combined with 5.

View Article and Find Full Text PDF

Purpose: Pelvic ring fractures involving the iliopubic rami can cause functional impairment. Percutaneous retrograde fixation is a less invasive procedure when compared to traditional open approaches, however precise anatomical knowledge is crucial for safe screw placement. This study aims to describe the morphology of the iliopubic rami, define a safety corridor for percutaneous screw fixation, specially focusing on the relationships between the iliopubic rami and neurovascular structures.

View Article and Find Full Text PDF

Posterior lumbar screw fixation is the most common surgical method for lumbar disc herniation, but patients often face multiple complications postoperatively. The occurrence of screw track loosening can lead to fusion failure and even life-threatening screw track extrusion. However, there is currently a lack of animal models specifically targeting changes in the screw track following lumbar screw fixation.

View Article and Find Full Text PDF

Purpose: To evaluate changes in implant stability quotient values of hydrophilic tissue-level implants over time, and to investigate the influence of local factors on variations in these values.

Methods: Fifty tapered, self-tapping, tissue-level implants with a hydrophilic surface were placed and monitored for 12 months. Implant stability quotient values were recorded at the time of insertion (T0) and monthly thereafter for 12 months.

View Article and Find Full Text PDF