3D Analysis of Tooth Movement Using 3D Technology.

Curr Osteoporos Rep

Structural Genomics Consortium, University of Oxford, Old Road Campus Research Building, Roosevelt Drive, Oxford, OX3 7DQ, UK.

Published: December 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose Of Review: 3D cone beam imaging (CBCT) has allowed clinicians to better understand the anatomical variations of cranial anatomy. One crucial aspect of this technology plays is the understanding of alveolar bone morphology and remodeling. Variations in cortical bone thickness between individuals have been reported. No published study has analyzed the relationship between cortical bone thickness and rate of tooth movement. The aim of this study is to begin answering the question: is there an association between rate of tooth movement and cortical bone thickness?

Recent Findings: Twenty-three patients underwent extraction of a single premolar in each of the four quadrants prior to orthodontic therapy. Routine clinical records including 3D CBCT images were acquired of all patients prior to first premolar extractions. Rate of tooth movement in each quadrant for each patient was determined via mesiodistal millimetric measurements obtained by a single calibrated operator. With CBCT images, cortical bone thickness was measured at various levels from the alveolar crest along the long axis of the to-be-extracted first premolars. The association between cortical bone thickness and rate of tooth movement was analyzed. Statistically significant associations were found between rate of tooth movement and cortical bone thickness at levels 2 mm, 5 mm, and 8 mm, apical to the alveolar crest in both the right and left maxillary quadrants (p < 0.05). Statistically significant associations were found between rate of tooth movement and cortical bone thickness at levels 5 mm and 8 mm apical to the alveolar crest in both mandibular quadrants (p < 0.05). Increased cortical bone thickness was associated with decreased rate of tooth movement. There was no statistically significant association between rate of tooth movement and cortical bone thickness 2 mm apical to the alveolar crest of the to-be-extracted first premolars in the mandibular left nor right quadrants (p > 0.05). Results suggest an inverse relationship may exist between cortical bone thickness and rate of tooth movement in both the maxilla and mandible. Cortical bone thickness may have the potential to serve as a predictive tool for rate of orthodontic tooth movement.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11914-020-00625-zDOI Listing

Publication Analysis

Top Keywords

tooth movement
24
cortical bone
24
bone thickness
20
rate tooth
20
thickness rate
8
movement cortical
8
cbct images
8
alveolar crest
8
bone
7
movement
6

Similar Publications

Objectives: This umbrella meta-analysis aimed to answer the clinical question: Do mini-screws and micro-implants improve specific orthodontic outcomes such as intermolar width, interpremolar width, suture expansion, molar movement, and skeletal width compared to conventional anchorage methods?

Materials And Methods: A systematic search was performed in PubMed, Scopus, ISI Web of Science, and Google Scholar up to October 2024. Systematic reviews and meta-analyses on mini-screws and micro-implants in orthodontic treatment were included. Methodological quality was assessed using AMSTAR 2, and a random-effects model was used to calculate effect sizes (ESs) and 95% confidence intervals (CIs).

View Article and Find Full Text PDF

Purpose Improved superelastic nickel-titanium (Ni-Ti) alloy wires (ISWs) can be used not only for aligning but also for closing the extraction space. The objective of this study was to measure and compare the force and moment generated during mandibular molar protraction using an ISW combined with either short or long hooks under simulated crowded dentition conditions. Materials and methods Assuming crowded dentition following mandibular first premolar extraction, we designed a three-tooth model simulating the canine, the second premolar, and the first molar.

View Article and Find Full Text PDF

All-In-One Iontronic Sensing Aligner for High-Precision 3D Orthodontic Force Monitoring.

Adv Sci (Weinh)

September 2025

Department of Orthodontics, National Center for Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing Key Laboratory of Digital Stomatology, NHC Key Laboratory of Digital Stomatology, NMPA Key

Clear aligners offer aesthetic and comfort advantages in orthodontics, yet their ability to deliver effective forces relies heavily on empirical judgment or large-scale optical scanning, lacking real-time quantitative evaluation. Integrating pressure sensors into aligners is a promising solution, but challenges in miniaturization, multi-dimensional sensing, measurement accuracy, and biocompatibility hinder clinical application. Here, an all-in-one Orthodontic Force Acquisition System (OFAS) is presented that enables real-time, 3D force monitoring using a cross-shaped iontronic sensing array and an origami-inspired, wireless battery-free readout circuit miniaturized for single-tooth placement.

View Article and Find Full Text PDF

Introduction Clear aligners have gained traction in pediatric orthodontics due to their aesthetic and hygienic advantages. However, their applicability and effectiveness in mixed dentition remain underexplored. This study aims to assess the pediatric dentists' perceptions, practices, and challenges associated with clear aligner therapy in mixed dentition.

View Article and Find Full Text PDF

Background: For orthodontists, the position of the incisors is a key factor in setting treatment goals. Achieving maximum stability requires that they be positioned in the medullary portion of the alveolar bone, balanced with the lingual and labial musculature. Incorrect orthodontic movements can result in root resorption, dehiscences, or even fenestrations.

View Article and Find Full Text PDF