98%
921
2 minutes
20
[This corrects the article DOI: 10.1098/rsos.200225.].
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7481713 | PMC |
http://dx.doi.org/10.1098/rsos.201375 | DOI Listing |
J Prosthodont
September 2025
Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
Purpose: This study aimed to evaluate the inherent and after cyclic loading fracture strength of implant-supported cantilevered fixed prostheses fabricated from recently introduced additively manufactured (AM) and subtractively manufactured (SM) materials, considering variations in prosthesis height.
Materials And Methods: Three cylinder-shaped master files (20 mm long and 11 mm wide) with varying heights (7, 11, and 15 mm) and a titanium-base (Ti-base) abutment space were designed. These designs were used to fabricate a total of 144 specimens with two AM resins indicated for definitive use (Crowntec; AM-CT and Flexcera Smile Ultra+; AM-FS), one high-impact polymer composite (breCAM.
Cureus
August 2025
Department of Thoracic Surgery, Attikon General Hospital, National and Kapodistrian University of Athens, Athens, GRC.
Left-sided partial anomalous pulmonary venous return (PAPVR) may remain clinically silent and undiagnosed until incidentally identified, potentially introducing complexity in perioperative assessment and management, particularly in patients with significant comorbidities. We report the case of a 77-year-old male with metastatic colorectal adenocarcinoma and a history of multiple right-sided pulmonary metastasectomies. He underwent a right completion upper bilobectomy.
View Article and Find Full Text PDFNAR Genom Bioinform
September 2025
Research Group for Genomic Epidemiology, National Food Institute, Technical University of Denmark, 2800 Kgs. Lyngby, Denmark.
Advances in Oxford Nanopore Technologies (ONT) with the introduction of the r10.4.1 flow cell have reduced the sequencing error rates to <1%.
View Article and Find Full Text PDFiScience
September 2025
School of Electric and Electrical Engineering, Shanghai University of Engineering Science, Shanghai, China.
Wafer thickness is a critical parameter in semiconductor manufacturing, influencing production costs, and chip performance. Traditional measurement methods using clamping devices often introduce errors due to uneven positioning or unstable clamping. This study enhances the dual-probe chromatic confocal system by incorporating a diffractive optical element that splits white light into three beams, with spectrometer wave peak counts detecting wafer tilt.
View Article and Find Full Text PDFNan Fang Yi Ke Da Xue Xue Bao
August 2025
College of Information Engineering, Sichuan Agricultural University, Ya'an 625014, China.
Objectives: We propose a YOLOv11-TDSP model for improving the accuracy of dental abnormality detection on panoramic oral X-ray images.
Methods: The SHSA single-head attention mechanism was integrated with C2PSA in the backbone layer to construct a new C2PSA_SHSA attention mechanism. The computational redundancy was reduced by applying single-head attention to some input channels to enhance the efficiency and detection accuracy of the model.