98%
921
2 minutes
20
The photopic negative response of the electroretinogram reflects retinal ganglion cell function and consequently aids diagnosis of optic nerve diseases including glaucoma. In this study, we assessed the efficacy of stimulation parameters for electroretinographic recordings of the multifocal photopic negative response (mfPhNR) for the detection of glaucoma and compared the diagnostic accuracy of electrophysiological, structural and functional measures of glaucoma. We compared the diagnostic performance of the mfPhNR for 6 different stimulation rates in a cohort of 24 controls, 10 glaucoma suspects (GLA ) and 16 glaucoma participants (GLA). A cross-modal comparison of the mfPhNR/b wave ratio was performed with the pattern electroretinogram (PERG), and the peripapillary retinal nerve fiber layer (pRNFL) thickness. These analyses were based on area under curves (AUC) obtained from receiver-operating-characteristics (ROC) and step-wise regression analyses. We found that compared to the other mfPhNR-conditions, the PhNR/b-wave ratio for the fastest stimulation condition had the highest AUC for GLA (0.84, P = 0.008, 95%CI: 0.71- 0.98), while the other modalities, i.e., PERG-amplitude and pRNFL had AUCs of 0.78 (P= 0.039), and 0.74 (P < 0.05), respectively. For GLA , the respective AUCs were 0.78 (P= 0.004), 0.85 (P< 0.001) and 0.87 (P< 0.001). pRNFL was the significant predictor for both mfPhNR/b-wave ratio [t (48) = 4, P = 0.0002] and for PERG amplitude [t (48) = 3.4, P = 0.001]. In conclusion, fast mfPhNR protocols outperform other multifocal PhNR protocols in the identification of glaucomatous damage especially for GLA and thus aid the early detection of glaucoma, indicating its value as a surrogate marker of early stage ganglion cell dysfunction.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.exer.2020.108242 | DOI Listing |
Vestn Oftalmol
September 2025
Krasnov Research Institute of Eye Diseases, Moscow, Russia.
Primary open-angle glaucoma (POAG) is characterized by chronic progressive damage to the retinal ganglion cell layer (GCL) and their axons, leading to gradual visual function loss. Currently, the gold standards for structural and functional assessment of the retina in glaucoma are static automated perimetry (SAP) and optical coherence tomography (OCT). However, in clinical practice, data from SAP and OCT may be insufficient to reliably determine the stage of glaucomatous optic neuropathy, monitor its progression, or differentiate it from other causes of visual dysfunction.
View Article and Find Full Text PDFJ Clin Med
August 2025
IRCCS-Fondazione Bietti, Via Livenza 1, 00198 Rome, Italy.
: Considering the lack of studies regarding the localized evaluation of the macular inner retina in multiple sclerosis patients without optic neuritis (MSnoON eyes), we investigated the structure and function of retinal ganglion cells (RGCs) located in different macular areas. : In 24 MSnoON patients (mean age: 45.22 ± 5.
View Article and Find Full Text PDFMult Scler Relat Disord
August 2025
Department of Ophthalmology, Otorhinolaryngology and Head and Neck Surgery, Ribeirão Preto Medical School, University of São Paulo, São Paulo, Brazil.
Aim: To compare retinal ganglion cell function between optic neuritis (ON) cases positive for anti-aquaporin-4 antibody (AQP4+) and myelin oligodendrocyte glycoprotein (MOG+).
Methods: Patients tested positive for AQP4 or MOG and history of ON at least six months prior to enrollment were included. An ophthalmological examination, visual acuity test (BCVA), visual field test (mean deviation, MD) and spectral-domain optical coherence tomography (OCT) were performed.
Int J Ophthalmol
August 2025
Department of Ophthalmology, AnZhen Hospital, Captial Medical University, Beijing 100011, China.
Aim: To analyze visual dysfunction in rats under simulated weightlessness (SW) by examining trans-laminar cribrosa pressure difference (TLCPD) and neuroimmune responses.
Methods: The 72 male Sprague-Dawley rats were randomly assigned into two groups (ground control and hindlimb unloading-simulated microgravity) using stratified randomization, with each group further subdivided into three exposure durations: SW 2-week (SW-2W), 4-week (SW-4W), and 8-week (SW-8W), =12 per subgroup. At the designated time points for each group, intraocular pressure (IOP) and intracranial pressure (ICP) were measured, and the trans-laminar cribrosa pressure difference (TLCPD) was calculated.
Int Ophthalmol
August 2025
G6 Electrophysiology Laboratory, Rua Doutor Diogo de Faria, São Paulo, São Paulo, 1202, Brazil.
Purpose: This study allows the functional evaluation of all retinal layers in individuals with extensive macular atrophy with pseudodrusen. The findings may contribute to the elucidation of the disease's pathophysiology. The purpose of this retrospective observational study is to determine ganglion cell function in individuals with extensive macular atrophy with pseudodrusen by measuring the photopic negative response.
View Article and Find Full Text PDF