The purpose of this study was to assess the correlation between tissue volume and blood flow of the flap in an animal model. Using animal model, tissue volume can be attenuated, and precise change of blood flow could be evaluated. We further investigate the relationship between blood flow and vascular density in the tissue. In this study, we assessed flap conductance (ml/min/mm Hg) as to evaluate the conductivity of blood flow into the flap. Japanese white rabbit was used (n = 7) for this study. The amount of blood flow of jejunal and latissimus dorsi muscle (LD) flaps was measured while removing the distal portion of the flap sequentially. Conductance at each time was calculated from blood pressure and blood flow volume. The tissue volume at each time was also measured. The correlation between conductance and volume was analyzed using a linear mixed model. Immunohistochemical evaluation of microvessel densities (MVD) in these tissues was also performed for CD31/PECAM1 positive area. Conductance and tissue volume were significantly correlated in both jejunal and LD flaps. As the volume increases by 1 cm, the conductance increased significantly by 0.012 ml/min/mm Hg in jejunum, and by 0.0047 ml/min/mm Hg in LD. Mean MVD was 1.15 ± 0.52% in the jejunum and 0.37 ± 0.29% in the LD muscle. In this study, we revealed that flap conductance is proportional to volume and proportional constant is different between the type of tissue. It suggests that the difference of MVD creates the unique conductance of each tissue.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7276411PMC
http://dx.doi.org/10.18999/nagjms.82.2.291DOI Listing

Publication Analysis

Top Keywords

blood flow
28
tissue volume
20
volume
9
tissue
8
flow flap
8
animal model
8
flap conductance
8
conductance tissue
8
flow
7
blood
7

Similar Publications

The global surge in the population of people 60 years and older, including that in China, challenges healthcare systems with rising age-related diseases. To address this demographic change, the Aging Biomarker Consortium (ABC) has launched the X-Age Project to develop a comprehensive aging evaluation system tailored to the Chinese population. Our goal is to identify robust biomarkers and construct composite aging clocks that capture biological age, defined as an individual's physiological and molecular state, across diverse Chinese cohorts.

View Article and Find Full Text PDF

Optimized FDA Blood Pump: A Case Study in System-Level Customized Ventricular Assist Device Designs.

Ann Biomed Eng

September 2025

Department of Mechanical Engineering, Koc University, Rumeli Feneri Campus, Sarıyer, 34450, Istanbul, Turkey.

Purpose: The design and development of ventricular assist devices have heavily relied on computational tools, particularly computational fluid dynamics (CFD), since the early 2000s. However, traditional CFD-based optimization requires costly trial-and-error approaches involving multiple design cycles. This study aims to propose a more efficient VAD design and optimization framework that overcomes these limitations.

View Article and Find Full Text PDF

Background: Fetal growth restriction (FGR) causes an adaptive redistribution of the cardiac output towards sustained cerebral vasodilation. However, the consequences of FGR and cerebral vasodilatation due to fetal hypoxia on the blood-brain barrier (BBB) are still poorly studied. This study assesses BBB permeability in the neonatal cortex of pups gestated under intrauterine hypobaric hypoxia.

View Article and Find Full Text PDF

[Anti-EJ antibody positive antisynthetase syndrome with pulmonary hypertention:a case report].

Zhonghua Jie He He Hu Xi Za Zhi

September 2025

Department of Cardio-Pulmonary Circulation, Shanghai Pulmonary Hospital, Tongji University School of Medicine, Shanghai 210032, China.

Antisynthetase syndrome(ASS) is an entity among the immune inflammatory myopathies(IIM), which always affects lungs. Interstitial lung disease(ILD) is common in ASS, while pulmonary hypertention(PH)is rarely observed. In this paper, we reported a case of ASS with ILD and PH.

View Article and Find Full Text PDF

Introduction: Benchtop and animal models have traditionally been used to study the propagation of Onyx Liquid Embolic Systems (Onyx) used in the treatment of brain arteriovenous malformations (AVM). However, such models are costly, do not provide sufficient detail to elucidate how variations in Onyx viscosity alter flow dynamics, and rely on some trial-and-error, resulting in elongated timelines for product development.

Objectives: The goal of this study was to leverage Computational Fluid Dynamics (CFD) simulations to predict the behavior of different Onyx formulations.

View Article and Find Full Text PDF