A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Imidazolium ionic-liquid-modified phenolic resin for solid-phase extraction of thidiazuron and forchlorfenuron from cucumbers. | LitMetric

Imidazolium ionic-liquid-modified phenolic resin for solid-phase extraction of thidiazuron and forchlorfenuron from cucumbers.

J Chromatogr A

Key Laboratory of Medicinal Chemistry and Molecular Diagnosis, College of Public Health, Hebei University, Baoding, 071002, China; Key Laboratory of Analytical Science and Technology of Hebei Province, College of Pharmaceutical Science, Hebei University, Baoding, 071002, China. Electronic address: y

Published: July 2020


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

An imidazolium ionic-liquid-modified phenolic resin (ILPR) was synthesized using 3-aminophenol as a functional monomer, glyoxylic acid as a green cross-linker, and polyethylene glycol 6000 as a porogen. The obtained ILPR showed better extraction of benzoylurea plant hormones thidiazuron and forchlorfenuron than the unmodified phenolic resin because the imidazolium IL provides more interaction modes with the analytes. ILPR, as a tailored adsorbent for solid-phase extraction, was coupled with high-performance liquid chromatography (ILPR‒SPE‒HPLC) for the simultaneous determination of thidiazuron and forchlorfenuron in cucumbers. Good linearity of the ILPR‒SPE‒HPLC method was obtained, ranging from 0.0100 to 5.00 μg g with a correlation coefficient (r) ≥ 0.9999. The recoveries of spiked samples ranged from 91.4% to 100.7% with a relative standard deviation of ≤ 6.0%.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2020.461192DOI Listing

Publication Analysis

Top Keywords

phenolic resin
12
thidiazuron forchlorfenuron
12
imidazolium ionic-liquid-modified
8
ionic-liquid-modified phenolic
8
solid-phase extraction
8
forchlorfenuron cucumbers
8
resin solid-phase
4
extraction thidiazuron
4
cucumbers imidazolium
4
resin ilpr
4

Similar Publications