A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Graphene oxide orientated by a magnetic field and application in sensitive detection of chemical oxygen demand. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

An upright GO (UGO) modified screen-printed electrode was prepared with the help of the external magnetic field for improving its electrochemical performance. The ratio of GO: Nafion and the magnetic field intensity on the properties of UGO were examined by scanning electron microscope, cyclic voltammetry and electrochemical impedance spectroscopy. The magnetic field intensity does not influence the electron transfer kinetics but increase the number of active sites and therefore enhance the electroactive surface area. In addition, the UGO electrode that was electrodeposited Ni nanoparticles (denotes as Ni NPs/UGO modified electrode) display excellent oxidation towards glycine using chronoamperometry. The Ni NPs/UGO modified electrode indicated an excellent performance for electrochemical COD (chemical oxide demand) analysis with a linear detection range of 0.1-400 mg/L and a lower detection limit of 0.02 mg/L. Moreover, this Ni NPs/UGO modified electrode can be applied to the rapid determination of COD in general real water samples. The results were in agreement with those obtained by using the standard method (ISO 6060).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2020.05.009DOI Listing

Publication Analysis

Top Keywords

magnetic field
16
nps/ugo modified
12
modified electrode
12
field intensity
8
electrode
5
graphene oxide
4
oxide orientated
4
magnetic
4
orientated magnetic
4
field
4

Similar Publications