98%
921
2 minutes
20
To report the implementation, dosimetric results of and early experiences with stereotactic accelerated partial breast irradiation (SAPBI) following breast conserving surgery (BCS) for postmenopausal low-risk St I-II invasive breast cancer (IBC) patients. Between November 2018 and August 2019, 27 patients were registered in our phase II prospective study. SAPBI was performed with Cyber-Knife (CK) M6 machine, in 4 daily fractions of 6.25 Gy to a total dose of 25 Gy. Respiratory movements were followed with implanted gold markers and Synchrony system. Corrections for patient displacement and respiratory movement during treatment were performed with the robotic arm. Early side effects, cosmetic results, and dosimetric parameters were assessed. The average volume of the surgical cavity, clinical target volume (CTV), and planning target volume (PTV_EVAL) were 8.1 cm (range: 1.75-27.3 cm), 55.3 cm (range: 26.2-103.5 cm), and 75.7 cm (range: 40-135.4 cm), respectively. The mean value of the PTV_eval/whole breast volume ratio was 0.09 (range: 0.04-0.19). No grade 2 or worst acute side-effect was detected. Grade 1 (G1) erythema occurred in 6 (22.2%) patients, while G1 oedema was reported by 3 (11.1%) cases. G1 pain was observed in 1 (3.4%) patient. Cosmetic result were excellent in 17 (62.9%) and good in 10 (37.1%) patients. SAPBI with CK is a suitable and practicable technique for the delivery of APBI after BCS for low-risk, St. I-II. IBC. Our early findings are encouraging, CK-SAPBI performed with four daily fractions is convenient and perfectly tolerated by the patients.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7471183 | PMC |
http://dx.doi.org/10.1007/s12253-020-00821-3 | DOI Listing |
J Appl Clin Med Phys
September 2025
Medical Physics Division, Department of Medical Innovation & Technology, CUHK Medical Centre, Hong Kong SAR, China.
Background: Patient-specific quality assurance (PSQA) is crucial in radiation therapy to ensure accurate and safe dose delivery. The Elekta Unity MR-Linac system, which combines MRI with a linear accelerator, presents unique challenges for conventional PSQA methods due to its adaptive capabilities and the presence of a magnetic field.
Purpose: This study introduced a novel PSQA method for the Elekta Unity MR-Linac system, utilizing treatment log files and fluence map verification to provide a more efficient alternative to traditional measurement-based techniques.
Med Phys
September 2025
Radiation Safety and Quality Assurance Division, National Cancer Center Hospital East, Chiba, Japan.
Background: Magnetic resonance imaging of polymer gel dosimeters remains the de facto standard to obtain high-quality dose information. However, magnetic resonance imaging scanner access is limited and scan times are long. x-Ray computed tomography-based polymer gel dosimeters (XCT-PGDs) offer convenience owing to easier access to CT scanners, especially cone-beam CT (CBCT) scanners integrated with linear accelerators, although they suffer from low dose resolution and high noise sensitivity.
View Article and Find Full Text PDFJ Egypt Natl Canc Inst
September 2025
Department of Radiation Oncology, Rajiv Gandhi Cancer Institute and Research Center, New Delhi, New Delhi, India.
Aim: This study aimed to evaluate the multifaceted clinical utility of the RUBY phantom as a comprehensive quality assurance (QA) platform in high-precision radiotherapy, particularly for stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT). The objective was to validate its performance in patient positioning, imaging system accuracy, isocenter congruency, and treatment plan verification across various complex clinical scenarios.
Materials And Methods: A series of QA workflows were conducted using the RUBY phantom and its dedicated modular inserts.
Anticancer Res
September 2025
Department of Radiation Oncology, China Medical University Hospital, Taichung, Taiwan, R.O.C.;
Background/aim: Stereotactic ablative radiotherapy (SABR) can deliver tumoricidal doses to hepatocellular carcinoma (HCC). To date, there is a paucity of research reporting the impact of maximal tumor diameter (MTD) on patients with HCC treated with SABR.
Patients And Methods: The medical records of patients with HCC with Barcelona Clinic Liver Cancer (BCLC) stage A to C diseases treated with linear accelerator-based SABR between 2015 and 2021 were reviewed.
Cureus
July 2025
Department of Neuroendocrinology, National Institute of Neurology and Neurosurgery "Manuel Velasco Suárez", Mexico City, MEX.
Background and objective Fractionated stereotactic radiotherapy (FSRT) and stereotactic radiosurgery (SRS) are commonly used in patients with growth hormone (GH)-secreting pituitary adenomas (PAs) who are not candidates for surgery, have residual disease postoperatively, or have failed or cannot access medical therapy. It is also considered a first-line option in elderly patients or those with comorbidities that contraindicate surgery. In this study, we aimed to evaluate the long-term outcomes of SRS and FSRT in patients with acromegaly who remained biochemically active despite prior surgical and/or medical treatment.
View Article and Find Full Text PDF