A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Fast and All-Optical Hydrogen Sensor Based on Gold-Coated Optical Fiber Functionalized with Metal-Organic Framework Layer. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Remote detection of hydrogen, without the utilization of electronic component or elevated temperature, is one of the hot topics in the hydrogen technology and safety. In this work, the design and realization of the optical fiber-based hydrogen sensor with unique characteristics are proposed. The proposed sensor is based on the gold-coated multimode fiber, providing the plasmon properties, decorated by the IRMOF-20 layer with high selectivity and affinity toward hydrogen. The IRMOF-20 layer was grown by a surface-assisted technique, and its formation and properties were studied using X-ray photoelectron spectroscopy, Raman, X-ray diffraction, and Brunauer-Emmett-Teller techniques. Simultaneous ellipsometry results indicate the apparent changes of the refractive index of the IRMOF-20 layer due to hydrogen sorption. As results, the presence of hydrogen led to the pronounced changes of plasmon band wavelength position as well as its intensity increase. The proposed hydrogen sensors were favorably distinguished by a high response/recovery rate, excellent selectivity toward the hydrogen, very low temperature dependency, functionality at room or lower temperature, insensitivity toward the humidity, and the presence of CO, CO, or NO. Additionally, the proposed hydrogen sensor showed good reversibility, reproducibility, and long-term stability.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acssensors.9b01074DOI Listing

Publication Analysis

Top Keywords

hydrogen sensor
12
irmof-20 layer
12
hydrogen
10
sensor based
8
based gold-coated
8
proposed hydrogen
8
fast all-optical
4
all-optical hydrogen
4
sensor
4
gold-coated optical
4

Similar Publications