Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The purpose of this study was to examine changes in fixation stability over time during binocular and monocular viewing in patients with age-related macular degeneration (AMD). Seventeen patients with AMD and 17 controls were enrolled. Using an EyeLink eyetracker (SR Research Ltd., Mississauga, Ontario, Canada), fixation stability was recorded binocularly and monocularly with each eye for a duration of 15 s while the fellow eye was covered. Fixation stability was analyzed over 3 s intervals for each condition using a 68% bivariate contour ellipse area. Fixation stability did not change with time during binocular viewing for both groups, both monocular conditions for the control group, and monocular viewing with the better eye for the AMD group. However, during monocular viewing with the worse eye, the test of within-subject contrasts showed linear improvement in fixation stability with time ( = 0.016). In conclusion, in patients with AMD, monocular fixational control with the worse eye is poor, but improves with time.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6835974PMC
http://dx.doi.org/10.3390/vision2040040DOI Listing

Publication Analysis

Top Keywords

fixation stability
24
monocular viewing
16
stability time
12
time binocular
12
changes fixation
8
binocular monocular
8
patients amd
8
group monocular
8
worse eye
8
stability
6

Similar Publications

Children with amblyopia read slower than their peers during binocular viewing. Ocular motor dysfunction typical of amblyopia may cause slow reading. It is unclear whether this is due to fixation instability or increased forward saccades.

View Article and Find Full Text PDF

Fibrin Sealant-Assisted Fixation of an Autologous Iliac Bone Graft in Orbital Floor Reconstruction.

J Craniofac Surg

September 2025

Division of Ophthalmic Plastic and Reconstructive Surgery, Sadik Eratik Eye Institute, Haydarpasa Numune Education and Research Hospital, University of Health Sciences.

Orbital floor fractures can lead to enophthalmos and diplopia, often requiring surgical intervention to restore orbital volume. Autologous iliac bone grafts are commonly used due to their biocompatibility and mechanical stability, but achieving adequate fixation remains a challenge. Traditional fixation methods, such as plates and screws, may introduce risks of foreign body reactions, graft displacement, and surgical morbidity.

View Article and Find Full Text PDF

Background: Choosing the appropriate implants for reconstruction in revision TKA is essential for long-term fixation. While cones and augments are routinely utilized to address tibial defects, the effect of augment location and size on the biomechanical stability of revision TKA constructs and the indications for the use of metaphyseal cones are not known.

Questions/purposes: Is the risk of cement-implant debonding of revision TKA constructs impacted by the thickness and location (medial versus bicompartmental) of tibial augments and the presence of metaphyseal cones during (1) a demanding daily activity like stair ascent and (2) torsional loads?

Methods: Under institutional review board approval, we developed patient-specific finite-element models of revision TKA from four patients (three males and one female, ages 50 to 80 years, BMI 27 to 37 kg/m2) who underwent two-stage revision and had a CT scan with no metal artifact after first-stage implant removal.

View Article and Find Full Text PDF

Membrane technology for gas separation is more efficient and energy-saving than thermally driven processes, including cryogenic distillation and adsorption. Metal-organic framework (MOF) and related glass membranes hold great potential for precise gas separation, but it remains challenging to construct ultrathin MOF glass membranes and optimize their transport pathways. In this study, a strategy based on vapor-linker deposition and melt-quenching is reported to design ultrathin zeolitic imidazolate framework (ZIF) glass membranes with node-missing defect passageways.

View Article and Find Full Text PDF

Objective: Due to its inherent high instability, the selection of fixation strategies for unilateral Denis type II sacral fractures remains a controversial challenge in the field of traumatic orthopedics. This study focuses on unilateral Denis type II sacral fractures. By applying three different fixation methods, it aims to explore their biomechanical properties and provide a theoretical basis for optimizing clinical fixation protocols.

View Article and Find Full Text PDF