98%
921
2 minutes
20
Purpose: Microbeam radiation therapy (MRT) is an emerging radiation oncology modality ideal for treating inoperable brain tumors. MRT employs quasi-parallel beams of low-energy x rays produced from modern synchrotrons. A tungsten carbide multislit collimator (MSC) spatially fractionates the broad beam into rectangular beams. In this study, the MSC creates beams 50 μm wide ("peaks") separated by a center-to-center distance of 400 μm ("valleys"). The peak to valley dose ratio (PVDR) is of critical importance to the efficacy of MRT. The underlying radiobiological advantage of MRT relies on high peak dose for tumor control and low valley dose for healthy tissue sparing. Cardio synchronous brain motion of the order 100-200 μm is comparable to microbeam width and spacing. The motion can have a detrimental effect on the PVDR, full width at half maximum (FWHM) of the microbeams, and ultimately the dose distribution. We present the first experimental measurement of the effect of brain motion on MRT dose distribution. Dosimetry in MRT is difficult due to the high dose rate (up to 15-20 kGy/s) and small field sizes.
Methods: A real-time dosimetry system based on a single silicon strip detector (SSSD) has been developed with spatial resolution ~10 μm. The SSSD was placed in a water-equivalent phantom and scanned through the microbeam distribution. A monodirectional positioning stage reproduced brain motion during the acquisition. Microbeam profiles were reconstructed from the SSSD and compared with Geant4 simulation and radiochromic HD-V2 film.
Results: The SSSD is able to reconstruct dose profiles within 2 μm compared to film. When brain motion is applied the SSSD shows a two time increase in FWHM of profiles and 50% reduction in PVDR. This is confirmed by Geant4 and film data.
Conclusions: Motion-induced misalignment and distortion of microbeams at treatment delivery will result in a reduced PVDR and increased irradiation of additional healthy tissue compromising the radiobiological effectiveness of MRT. The SSSD was able to reconstruct dose profiles under motion conditions and predict similar effects on FWHM and PVDR as by the simulation. The SSSD is a simple to setup, real-time detector which can provide time-resolved high spatial resolution dosimetry of microbeams in MRT.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/mp.13899 | DOI Listing |
Sports Med Open
September 2025
Division of Physiological Sciences, Department of Human Biology, Faculty of Health Sciences, University of Cape Town, Newlands, Cape Town, 7725, South Africa.
Background: In tackle-collision sports, the tackle has the highest incidence, severity, and burden of injury. Head injuries and concussions during the tackle are a major concern within tackle-collision sports. To reduce concussion and head impact risk, evaluating optimal tackle techniques to inform tackle-related prevention strategies has been recommended.
View Article and Find Full Text PDFElife
September 2025
Department of Chemical and Biological Engineering, University of Colorado Boulder, Boulder, United States.
The microglial surface protein Triggering Receptor Expressed on Myeloid Cells 2 (TREM2) plays a critical role in mediating brain homeostasis and inflammatory responses in Alzheimer's disease (AD). The soluble form of TREM2 (sTREM2) exhibits neuroprotective effects in AD, though the underlying mechanisms remain elusive. Moreover, differences in ligand binding between TREM2 and sTREM2, which have major implications for their roles in AD pathology, remain unexplained.
View Article and Find Full Text PDFFront Neurol
August 2025
Division of Neurology, Department of Medicine, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.
Introduction: A subset of patients with homonymous hemianopia can consciously perceive motion within their blind visual fields-a phenomenon known as the Riddoch phenomenon. However, the factors predicting this residual motion perception remain poorly understood. This study aims to identify clinical and neuroanatomical predictors of the Riddoch phenomenon in stroke patients.
View Article and Find Full Text PDFJ Neurosci
September 2025
Jefferson Moss Rehabilitation Research Institute, Thomas Jefferson University, Elkins Park, PA 19027.
Tool use is a complex motor planning problem. Prior research suggests that planning to use tools involves resolving competition between different tool-related action representations. We therefore reasoned that competition may also be exacerbated with tools for which the motions of the tool and the hand are incongruent (e.
View Article and Find Full Text PDFHum Brain Mapp
September 2025
Department of Neuropediatrics, General Pediatrics, Diabetology, Endocrinology, Social Pediatrics, University Children's Hospital, Tübingen, Germany.
Subject motion is a significant problem for the analysis of functional MRI data and is usually described by "total displacement" or "scan-to-scan displacement". Neither parameter, however, takes into account voxel size, which clearly is relevant for the actual effects of motion on the data. Consequently, it is hitherto impossible to compare motion between subjects/studies acquired using different voxel dimensions, precluding the development of generally applicable recommendations for fMRI quality control procedures.
View Article and Find Full Text PDF