Article Abstract

Fabrication of a spherical multi-compartment MRI phantom is demonstrated that can be used to validate magnetic resonance (MR)-based susceptibility imaging reconstruction. The phantom consists of a 10 cm diameter gelatin sphere that encloses multiple smaller gelatin spheres doped with different concentrations of paramagnetic contrast agents. Compared to previous multi-compartment phantoms with cylindrical geometry, the phantom provides the following benefits: (1) no compartmental barrier materials are used that can introduce signal voids and spurious phase; (2) compartmental geometry is reproducible; (3) spherical susceptibility boundaries possess a ground-truth analytical phase solution for easy experimental validation; (4) spherical geometry of the overall phantom eliminates background phase due to air-phantom boundary in any scan orientation. The susceptibility of individual compartments can be controlled independently by doping. During fabrication, formalin cross-linking and water-proof surface coating effectively blocked water diffusion between the compartments to preserve the phantom's integrity. The spherical shapes were realized by molding the inner gel compartments in acrylic spherical shells, 3 cm in diameter, and constructing the whole phantom inside a larger acrylic shell. From gradient echo images obtained at 3T, we verified that the phantom produced phase images in agreement with the theoretical prediction. Factors that limit the agreement include: air bubbles trapped at the gel interfaces, imperfect magnet shimming, and the susceptibility of external materials such as the phantom support hardware. The phantom images were used to validate publicly available codes for quantitative susceptibility mapping. We believe that the proposed phantom can provide a useful testbed for validation of MR phase imaging and MR-based magnetic susceptibility reconstruction.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6681938PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0220639PLOS

Publication Analysis

Top Keywords

phantom
10
fabrication spherical
8
magnetic susceptibility
8
susceptibility imaging
8
geometry phantom
8
susceptibility
7
spherical
5
phase
5
spherical inclusion
4
inclusion phantom
4

Similar Publications

Volumetric modulated arc therapy (VMAT) for lung cancer involves complex multileaf collimator (MLC) motion, which increases sensitivity to interplay effects with tumour motion. Current dynamic conformal arc methods address this issue but may limit the achievable dose distribution optimisation compared with standard VMAT. This study examined the clinical utility of a VMAT technique with monitor unit limits (VMATliMU) to mimic conformal arc delivery and reduce interplay effects while maintaining plan quality.

View Article and Find Full Text PDF

In ultrasound imaging, propagation of an acoustic wavefront through heterogeneous media causes phase aberrations that degrade the coherence of the reflected wavefront, leading to reduced image resolution and contrast. Adaptive imaging techniques attempt to correct this phase aberration and restore coherence, leading to improved focusing of the image. We propose an autofocusing paradigm for aberration correction in ultrasound imaging by fitting an acoustic velocity field to pressure measurements, via optimization of the common midpoint phase error (CMPE), using a straight-ray wave propagation model for beamforming in diffusely scattering media.

View Article and Find Full Text PDF

Magnetic nanoparticles are widely explored in biomedical applications, particularly as MRI contrast agents and for magnetic hyperthermia. However, their photothermal capabilities under near-infrared (NIR) irradiation remain underexplored in realistic, tissue-like environments. This study provides a comprehensive assessment of ultrasmall FeO nanoparticles (9.

View Article and Find Full Text PDF

Purpose: To develop and validate a deep learning-based model for automated evaluation of mammography phantom images, with the goal of improving inter-radiologist agreement and enhancing the efficiency of quality control within South Korea's national accreditation system.

Materials And Methods: A total of 5,917 mammography phantom images were collected from the Korea Institute for Accreditation of Medical Imaging (KIAMI). After preprocessing, 5,813 images (98.

View Article and Find Full Text PDF

Purpose: A newly developed device, the Partially Automated Needle Direction Assistant, was designed to assist with computed tomography-guided oblique needle puncture. This device allows operators to accurately and in real-time determine the puncture angle based on the target lesion and needle entry point. The purpose of this report is to introduce the concept of Partially Automated Needle Direction Assistant and present results from an initial phantom study.

View Article and Find Full Text PDF