A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Changing the Blood Test: Accurate Determination of Mercury(II) in One Microliter of Blood Using Oriented ZnO Nanobelt Array Film Solution-Gated Transistor Chips. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The measurement of ultralow concentrations of heavy metal ions (HMIs) in blood is challenging. A new strategy for the determination of mercury ions (Hg ) based on an oriented ZnO nanobelt (ZnO-NB) film solution-gated field-effect transistor (FET) chip is adopted. The FET chips are fabricated with ZnO-NB film channels with different orientations utilizing the Langmuir-Blodgett (L-B) assembly technique. The combined simulation and I-V behavior results show that the nanodevice with ZnO-NBs parallel to the channel has exceptional performance. The sensing capability of the oriented ZnO-NB film FET chips corresponds to an ultralow minimum detectable level (MDL) of 100 × 10 m in deionized water due to the change in the electrical double layer (EDL) arising from the synergism of the field-induced effect and the specific binding of Hg to the thiol groups (-SH) on the film surface. Moreover, the prepared FET chips present excellent selectivity toward Hg , excellent repeatability, and a rapid response time (less than 1 s) for various Hg concentrations. The sensing performance corresponds to a low MDL of 10 × 10 m in real samples of a drop of blood.

Download full-text PDF

Source
http://dx.doi.org/10.1002/smll.201902433DOI Listing

Publication Analysis

Top Keywords

zno-nb film
12
fet chips
12
oriented zno
8
zno nanobelt
8
film solution-gated
8
film
5
changing blood
4
blood test
4
test accurate
4
accurate determination
4

Similar Publications