Article Abstract

Purpose: Increasing radiation dose to the heart is associated with worse survival in stage III non-small cell lung cancer. We sought to evaluate the ability of optimized volumetric modulated arc therapy (VMAT) and intensity modulated proton therapy (IMPT) to spare cardiac substructures. We also wanted to determine how a cardiac optimization treatment planning algorithm influences dose distribution to other thoracic organs at risk (OARs).

Methods And Materials: Cardiac substructures were retrospectively contoured for all patients with stage III non-small cell lung cancer who were treated at our institution with VMAT to 60 Gy in 2-Gy fractions. The structures included valves, atrioventricular node, coronary arteries, chambers, and great vessels. New cardiac-optimized VMAT plans were created to spare these structures while preserving planning target volume coverage and maintaining standard dose constraints to OARs. Dosimetry variables for the new cardiac-optimized VMAT plans were compared via paired t test with the original VMAT plans. IMPT plans were also created, and the cardiac-optimized VMAT plans were then similarly compared with the IMPT plans.

Results: Twenty-six patients who were treated from July 2013 to September 2017 were included. Compared with the original VMAT plans, statistically significant improvements were demonstrated for all cardiac structures for the new cardiac-optimized VMAT plans while maintaining or improving appropriate lung, esophagus, and spinal cord constraints and planning target volume coverage goals. Compared with cardiac-optimized VMAT, IMPT demonstrated additional statistically significant improvements for some cardiac dosimetry metrics while maintaining or improving other thoracic OAR constraints.

Conclusions: VMAT is now widely available, and high-quality VMAT plans that incorporate cardiac substructures into the optimization process can provide overall improvements in dose to OARs and, in particular, substantial sparing of critical cardiac structures. IMPT provides some incremental dosimetric improvements beyond cardiac-optimized VMAT, the clinical significance of which remains uncertain.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6718306PMC
http://dx.doi.org/10.1016/j.prro.2019.04.013DOI Listing

Publication Analysis

Top Keywords

vmat plans
28
cardiac-optimized vmat
24
cardiac substructures
16
non-small cell
12
cell lung
12
lung cancer
12
vmat
12
optimized volumetric
8
volumetric modulated
8
modulated arc
8

Similar Publications

Background: Radiotherapy workflows conventionally deliver one treatment plan multiple times throughout the treatment course. Non-coplanar techniques with beam angle optimization or dosimetrically optimized pathfinding (DOP) exploit additional degrees of freedom to improve spatial conformality of the dose distribution compared to widely used techniques like volumetric-modulated arc therapy (VMAT). The temporal dimension of dose delivery can be exploited using multiple plans (sub-plans) within one treatment course.

View Article and Find Full Text PDF

Implementation of intelligent All-in-one technology in rectal cancer radiotherapy: A retrospective study on automation efficiency and safety.

J Appl Clin Med Phys

September 2025

Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Department of Oncology, Shanghai Clinical Research Center for Radiation Oncology, Shanghai Key Laboratory of Radiation Oncology, Shanghai Medical College, Fudan University, Shanghai, China.

Purpose: This study aims to assess percentage of automated AIO plans that met clinical treatment standards of radiotherapy plans generated by the fully automated All-in-one (AIO) process.

Methods: The study involved 117 rectal cancer patients who underwent AIO treatment. Fully automated regions of interest (ROI) and treatment plans were developed without manual intervention, comparing them to manually generated plans used in clinical practice.

View Article and Find Full Text PDF

Purpose: Real‑time magnetic resonance-guided radiation therapy (MRgRT) integrates MRI with a linear accelerator (Linac) for gating and adaptive radiotherapy, which requires robust image‑quality assurance over a large field of view (FOV). Specialized phantoms capable of accommodating this extensive FOV are therefore essential. This study compares the performance of four commercial MRI phantoms on a 0.

View Article and Find Full Text PDF

Introduction: The role of imaging in radiotherapy is becoming increasingly important. Verification of imaging parameters prior to treatment planning is essential for safe and effective clinical practice.

Methods: This study described the development and clinical implementation of ImageCompliance, an automated, GUI-based script designed to verify and enforce correct CT and MRI parameters during radiotherapy planning.

View Article and Find Full Text PDF

Purpose: The development of on-board cone-beam computed tomography (CBCT) has led to improved target localization and evaluation of patient anatomical change throughout the course of radiation therapy. HyperSight, a newly developed on-board CBCT platform by Varian, has been shown to improve image quality and HU fidelity relative to conventional CBCT. The purpose of this study is to benchmark the dose calculation accuracy of Varian's HyperSight cone-beam computed tomography (CBCT) on the Halcyon platform relative to fan-beam CT-based dose calculations and to perform end-to-end testing of HyperSight CBCT-only based treatment planning.

View Article and Find Full Text PDF