Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Electronic cigarettes (E-cigarettes) generate aerosol containing metal contaminants. Our goals were to quantify aerosol metal concentrations and to compare the effects of power setting and device type (closed-system vs. open-system) on metal release.

Methods: Aerosol samples were collected from two closed-system devices (a cigalike and pod) and two open-system devices (mods). Each open-system device was operated at three different power settings to examine the effect of device power on metal release. Concentrations of 14 metals in e-cigarette aerosol collected via droplet deposition were measured using inductively coupled plasma mass spectroscopy. Aerosol metal concentrations were reported as mass fractions (μg/kg) in the e-liquid.

Results: For open-system device 1 (OD1), median arsenic (As), chromium (Cr), copper (Cu), iron (Fe), manganese (Mn), nickel (Ni), lead (Pb), antimony (Sb), tin (Sn), and zinc (Zn) concentrations increased 14, 54, 17, 30, 41, 96, 14, 81, 631, and 7-fold when the device power was increased from low (20 W) to intermediate (40 W) setting. When the power was further increased from intermediate (40 W) to high (80 W) setting, concentrations of As, Cr, Cu, Mn, Ni, and Sb did not change significantly. For open-system device 2 (OD2), Cr and Mn concentrations increased significantly when device power was increased from low (40 W) to intermediate (120 W) setting, and then decreased significantly when power was further increased from intermediate (120 W) to high (200 W) setting. Among the four devices, aerosol metal concentrations were higher for the open-system than the closed-system devices, except for aluminum (Al) and uranium (U). For Cr, median (interquartile range) concentrations (μg/kg) from the open-system devices were 2.51 (1.55, 4.23) and 15.6 (7.88, 54.5) vs. 0.39 (0.05, 0.72) and 0.41 (0.34, 0.57) for the closed-system devices. For Ni, concentrations (μg/kg) from the open-system devices were 793 (508, 1169) and 2148 (851, 3397) vs. 1.32 (0.39, 3.35) and 11.9 (10.7, 22.7) from the closed-system devices. Inhalation of 0% and 100% of samples from OD1, 7.4% and 88.9% from OD2 by typical e-cigarette users would exceed chronic minimum risk levels (MRL) of Mn and Ni, respectively. No MRL exceedance was predicted for the closed-system devices. A large fraction of users of OD1 (100%) and OD2 (77.8%) would be exposed to Ni levels higher than those from reference tobacco cigarette 3R4F.

Conclusions: Our findings suggest that power setting and device type affect metal release from devices to aerosol which would subsequently be inhaled by users. Metal concentrations from open-system devices first increased with device power, and then leveled off for most metals. Open-system devices generate aerosol with higher metal concentrations than closed-system devices. These findings inform tobacco regulatory science, policy makers and health professionals on potential metal health risks associated with e-cigarette use, design and manufacturing.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7079580PMC
http://dx.doi.org/10.1016/j.envres.2019.04.003DOI Listing

Publication Analysis

Top Keywords

closed-system devices
28
metal concentrations
24
open-system devices
20
aerosol metal
16
device power
16
power increased
16
devices
14
open-system device
12
metal
11
open-system
11

Similar Publications

BackgroundMany oral medications are manufactured as solid dosage forms, posing challenges for patients with dysphagia-including older adults and children-and creating occupational hazards for healthcare workers who must crush or manipulate hazardous drugs. Existing methods for preparing such medications often involve open systems, exposing staff to cytotoxic agents and risking cross-contamination.ObjectiveTo develop and evaluate a novel, single-use closed-system drug-transfer device (CSTD) designed to crush and dissolve or suspend solid oral medications within a sealed environment, enhancing safety for healthcare workers and improving medication access for patients with swallowing difficulties.

View Article and Find Full Text PDF

Triboelectric nanogenerators (TENGs) are positioned as a critical sustainable power solution for harvesting low-frequency mechanical energy or sensing. Although solid-solid contact-based TENGs can provide sustainable power to diminish external battery reliance and enhance portability and operational longevity, suboptimal energy output at low-frequency excitation, irreversible material damage under long-term operation and inadequate energy supply remain a challenge. Solid-liquid contact-based TENGs present an alternative approach, but rigid and bulky configurations hinder their integration toward wearable devices and the development of real applications.

View Article and Find Full Text PDF

Optimizing T cell transduction: a novel transduction device for efficient and scalable gene delivery.

J Transl Med

August 2025

Bioprocessing Technology Institute (BTI), Agency for Science, Technology and Research (A*STAR), 20 Biopolis Way, Singapore, 138668, Singapore.

Background: Viral transduction is a critical step in the manufacturing of genetically modified T cells for immunotherapies, yet conventional transduction methods suffer from low to medium efficiency, high vector consumption, and limited scalability.

Methods: To address these challenges, we introduce the Transduction Boosting Device (TransB), an innovative, automated, and closed-system platform designed to enable efficient and scalable gene delivery and overcome the limitations of conventional transduction methods. TransB improves cell-virus interactions by facilitating proximity between target cells and viral vectors.

View Article and Find Full Text PDF

Titanium surface functionalization with calcium-doped ZnO nanoparticles for hard tissue implant applications.

SLAS Technol

August 2025

Department of Biomedical Engineering and Sciences, School of Mechanical & Manufacturing Engineering, National University of Sciences and Technology (NUST), Islamabad 44000, Pakistan.

Implant-associated infections remain a significant challenge in orthopaedic and dental implants because they frequently result in implant failure, extended hospital stays, reoperations, and increased healthcare costs. Studies have shown that the cost of managing orthopaedic implant infections can range from USD 30,000 to over USD 100,000 per case, depending on severity and required surgical interventions. One of the primary pathogens responsible for these infections is Staphylococcus aureus, known for its potential to make biofilms on the surfaces of implants.

View Article and Find Full Text PDF

Background: Closed-system drug transfer devices (CSTDs) are known to be effective in reducing hazardous drug contamination and, in turn, the risk of exposure for health care workers. In response, the Fraser Health Authority in British Columbia had plans to introduce CSTDs into practice.

Objectives: To confirm the effectiveness of CSTDs in reducing hazardous drug contamination and to understand health care workers' perspectives regarding the change management process for CSTD implementation.

View Article and Find Full Text PDF