Background: Autoantibodies against apolipoprotein A1 (anti-apoA1 IgG) have emerged as an independent biomarker for cardiovascular disease and mortality. Across studies, different ELISA methods have been used to measure the level of circulating anti-apoA1 IgG which could lead to substantial result differences between assays.
Objectives: To make a comparative study of available anti-apoA1 IgG detection methods and to determine whether the choice of matrix sample (serum vs plasma) could influence the results.
Methods: Blood samples were obtained from 160 healthy blood donors and collected on 4 different matrixes (serum, plasma-EDTA, -citrate, -lithium-heparinate). Anti-apoA1 IgG was measured using two homemade (Geneva's and Lisbon's) and one commercial ELISA kits. Passing-Bablok and Bland-Altman were used to compare the results. Anti-apoA1 IgG seropositivity cut-offs were defined according to the user's/manufacturer's criterion.
Results: The current results showed substantial differences between those 3 assays. The dynamic ranges were significantly different, the commercial kit displaying the narrowest one. Passing-Bablok analysis demonstrated important proportional and constant biases between assays. The anti-apoA1 IgG seropositivity rate in Geneva, Lisbon and commercial assays varied between 24.5% and 1.9%. Matrix comparisons demonstrated that the matrix choice (plasma versus serum) influenced anti-apoA1 IgG results as well as the seropositivity rate in an assay-dependent manner. The coating antigen source was identified as important factor underlying results heterogeneity across assays.
Conclusions: These results highlight the impact of the method and the cut-off used on anti-apoA1 IgG results and emphasize the need of standardizing existing assays. Given the important matrix influence, we suggest to use serum as matrix of choice.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jim.2019.03.011 | DOI Listing |
Front Cardiovasc Med
February 2024
Division of Laboratory Medicine, Diagnostic Department, Geneva University Hospitals, Geneva, Switzerland.
Objective: This study aimed to study the relationship between auto-antibodies against apolipoprotein A1 (anti-apoA1 IgG), human immunodeficiency virus (HIV) infection, anti-retroviral therapy (ART), and the tryptophan pathways in HIV-related cardiovascular disease.
Design: This case-control study conducted in South Africa consisted of control volunteers ( = 50), people living with HIV (PLWH) on ART ( = 50), and untreated PLWH ( = 44). Cardiovascular risk scores were determined, vascular measures were performed, and an extensive biochemical characterisation (routine, metabolomic, and inflammatory systemic profiles) was performed.
Rheumatology (Oxford)
August 2023
Area of Immunology, Department of Functional Biology, Faculty of Medicine, University of Oviedo, Oviedo, Spain.
Objective: Chronic inflammation and immune dysregulation are crucial mechanisms for atherosclerosis in RA. Recent evidence suggests a link via humoral responses against high-density lipoproteins (HDL). This study aimed to characterize the specificity, clinical relevance and emergence of humoral responses against HDL along disease course, especially during the earliest phases of arthritis.
View Article and Find Full Text PDFObjectives: Autoantibodies against apolipoprotein A1 (anti-apoA1 IgGs) and its C-terminal region (cter apoA1) have emerged as an independent biomarker for cardiovascular disease. Cter apoA1 mimetic peptides were shown to reverse the deleterious anti-apoA1 IgG effects . We evaluated the association of anti-cter apoA1 IgGs with overall mortality in the general population and tested the ability of a cter apoA1 mimetic peptide to reverse the anti-apoA1 IgG-induced inflammatory response and mortality and , respectively.
View Article and Find Full Text PDFRheumatology (Oxford)
March 2020
Division of Immunology and Allergy, University Hospital and School of Medicine, Geneva, Switzerland.
Objectives: Apolipoprotein A-1 (ApoA-1) is a protein fraction of the high-density lipoproteins with anti-inflammatory and antioxidant properties that play a major role in reverse cholesterol transport. The presence of anti-ApoA-1 IgG has been reported in SLE to be variably associated with disease activity or cardiovascular events (CVEs). We assessed the clinical performance of anti-ApoA-1 IgG and of antibodies directed against its immunodominant F3L1 peptide (F3L1 IgG) in a well-characterized Swiss SLE cohort study.
View Article and Find Full Text PDFJ Immunol Methods
June 2019
Division of Laboratory Medicine, Diagnostic Department, Geneva University Hospitals, 4 rue Gabrielle-Perret-Gentil, 1205 Geneva, Switzerland; Department of Medical Specialties, Faculty of Medicine, University of Geneva, 1 rue Michel Servet, 1205 Geneva, Switzerland.
Background: Autoantibodies against apolipoprotein A1 (anti-apoA1 IgG) have emerged as an independent biomarker for cardiovascular disease and mortality. Across studies, different ELISA methods have been used to measure the level of circulating anti-apoA1 IgG which could lead to substantial result differences between assays.
Objectives: To make a comparative study of available anti-apoA1 IgG detection methods and to determine whether the choice of matrix sample (serum vs plasma) could influence the results.