Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Rationale And Objectives: We describe our preliminary experience using a 2D turbo gradient- and spin-echo (TGSE) diffusion-weighted (DW) pulse sequence with non-Cartesian BLADE trajectory at 3 T in pediatric patients. We compared the TGSE BLADE to conventional DW spin-echo echo-planar imaging (SE-EPI) in pediatric brain imaging, assessing the presence of artifacts from signal pile-ups, geometric distortion, motion, susceptibility from air-tissue interface, shunts and orthodontia, and diagnostic image quality.

Materials And Methods: Data were acquired in 53 patients (10.4 ± 7.9 years). All DW imaging data were acquired precontrast, with SE-EPI first. A four-point scale for rating was used-1 (best) and 4 (worst). A neuroradiologist scored the two sequences and further noted whether the TGSE BLADE approach or SE-EPI was preferred in each case. Apparent diffusion coefficients were compared quantitatively between the two sequences in a subset of 16 patients, in 41 separate regions of interests including caudate nucleus, putamen, globus pallidus, thalamus, and pathological areas.

Results: In 43.4% of the cases, TGSE BLADE was preferred; in 49.1% of the cases, both sequences were preferred equally. Average scores for SE-EPI were 2.2 ± 0.8 versus TGSE's 1.2 ± 0.4 in assessing diagnostic quality (p < 0.05). Motion artifacts were minimal on both sequences in 92.5% of the cases. In the TGSE BLADE scores, no case received a "4" for significant artifacts with marginally acceptable image quality. Apparent diffusion coefficients values between the two sequences were statistically similar, with a linear regression slope of 0.92 (r = 0.97).

Conclusion: TGSE BLADE DW imaging exhibited less geometric distortion in the brain and reduced signal pile-ups in areas of high susceptibility than conventional SE-EPI.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.acra.2019.02.002DOI Listing

Publication Analysis

Top Keywords

tgse blade
20
turbo gradient-
8
gradient- spin-echo
8
spin-echo echo-planar
8
preliminary experience
8
signal pile-ups
8
geometric distortion
8
data acquired
8
apparent diffusion
8
diffusion coefficients
8

Similar Publications

Comparison of SS-EPI DWI and one-minute TGSE-BLADE DWI for diagnosis of acute infarction.

Sci Rep

February 2025

Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan.

The efficacy of 2D turbo gradient- and spin-echo diffusion-weighted imaging with non-Cartesian BLADE trajectory (TGSE-BLADE DWI) has not been well studied for acute stroke due to its long acquisition time. This study was performed to compare distortion, artifacts and image quality between single-shot echo planar imaging (SS-EPI) DWI and TGSE-BLADE DWI with acquisition time reduced to 1 min by simultaneous multi-slice (SMS) imaging, and to evaluate the diagnostic performance of TGSE-BLADE DWI for acute infarctions. Total 104 patients with a past history of stroke or symptoms suspicious for acute infarction or who had undergone surgery for brain tumor within two days were prospectively enrolled.

View Article and Find Full Text PDF

Comparison of DWI techniques in patients with epidermoid cyst: TGSE-BLADE DWI vs. SS-EPI DWI.

Jpn J Radiol

May 2025

Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawaharacho, Kyoto, 6068507, Japan.

Purpose: To compare quantitative values and image quality between single-shot echo-planar imaging (SS-EPI) diffusion-weighted imaging (DWI) and two-dimensional turbo gradient- and spin-echo DWI with non-Cartesian BLADE trajectory (TGSE-BLADE DWI) in patients with epidermoid cyst.

Methods: Patients with epidermoid cyst who underwent both SS-EPI DWI and TGSE-BLADE DWI were included in this study. Two raters placed ROIs encircling the entire epidermoid cyst on SS-EPI DWI, and then on TGSE-BLADE DWI.

View Article and Find Full Text PDF

To investigate feasibility and diagnostic performance of turbo gradient and spin-echo BLADE (proprietary name for Periodically Rotated Overlapping ParallEL Lines with Enhanced Reconstruction [PROPELLER] in Siemens MR systems)-diffusion weighted imaging (TGSE-BLADE-DWI) for depicting extraocular muscle (EOM) involvement and activity in thyroid-associated ophthalmopathy (TAO), and to compare TGSE-BLADE-DWI with readout-segmented echo-planar imaging (RESOLVE). Thirty-five patients with identified TAO underwent the two DWI scans. Two radiologists visually scored the image quality of the two DWIs with respect to the susceptibility artifacts and geometric distortions on a three-point scale.

View Article and Find Full Text PDF

This study aimed to evaluate the reliability of apparent diffusion coefficient (ADC) values generated with two-dimensional turbo gradient- and spin-echo with BLADE trajectory diffusion-weighted imaging (TGSE-BLADE-DWI) sequence using a breast diffusion phantom. TGSE-BLADE-DWI and single-shot spin-echo echo-planar imaging (SS-EPI-DWI) were performed using a 3.0 T magnetic resonance imaging scanner.

View Article and Find Full Text PDF

Comparison of TGSE-BLADE DWI, RESOLVE DWI, and SS-EPI DWI in healthy volunteers and patients after cerebral aneurysm clipping.

Sci Rep

October 2022

Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawaharacho, Sakyoku, Kyoto, 6068507, Japan.

Diffusion-weighted magnetic resonance imaging is prone to have susceptibility artifacts in an inhomogeneous magnetic field. We compared distortion and artifacts among three diffusion acquisition techniques (single-shot echo-planar imaging [SS-EPI DWI], readout-segmented EPI [RESOLVE DWI], and 2D turbo gradient- and spin-echo diffusion-weighted imaging with non-Cartesian BLADE trajectory [TGSE-BLADE DWI]) in healthy volunteers and in patients with a cerebral aneurysm clip. Seventeen healthy volunteers and 20 patients who had undergone surgical cerebral aneurysm clipping were prospectively enrolled.

View Article and Find Full Text PDF