Article Abstract

Diffusion-weighted magnetic resonance imaging is prone to have susceptibility artifacts in an inhomogeneous magnetic field. We compared distortion and artifacts among three diffusion acquisition techniques (single-shot echo-planar imaging [SS-EPI DWI], readout-segmented EPI [RESOLVE DWI], and 2D turbo gradient- and spin-echo diffusion-weighted imaging with non-Cartesian BLADE trajectory [TGSE-BLADE DWI]) in healthy volunteers and in patients with a cerebral aneurysm clip. Seventeen healthy volunteers and 20 patients who had undergone surgical cerebral aneurysm clipping were prospectively enrolled. SS-EPI DWI, RESOLVE DWI, and TGSE-BLADE DWI of the brain were performed using 3 T scanners. Distortion was the least in TGSE-BLADE DWI, and lower in RESOLVE DWI than SS-EPI DWI near air-bone interfaces in healthy volunteers (P < 0.001). Length of clip-induced artifact and distortion near the metal clip were the least in TGSE-BLADE DWI, and lower in RESOLVE DWI than SS-EPI DWI (P < 0.01). Image quality scores for geometric distortion, susceptibility artifacts, and overall image quality in both healthy volunteers and patients were the best in TGSE-BLADE DWI, and better in RESOLVE DWI than SS-EPI DWI (P < 0.001). Among the three DWI sequences, image quality was the best in TGSE-BLADE DWI in terms of distortion and artifacts, in both healthy volunteers and patients with an aneurysm clip.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9586944PMC
http://dx.doi.org/10.1038/s41598-022-22760-6DOI Listing

Publication Analysis

Top Keywords

healthy volunteers
16
tgse-blade dwi
12
resolve dwi
12
ss-epi dwi
12
volunteers patients
12
cerebral aneurysm
12
dwi
9
dwi resolve
8
dwi ss-epi
8
patients cerebral
8

Similar Publications

A rapid and specific liquid chromatography-tandem mass spectrometry method with a wide linear range was developed and validated for the simultaneous quantification of Vitamin K1 (VK1) trans- and cis- isomers in human plasma. Bovine serum albumin solution (15%) served as a surrogate matrix for preparing the calibrators to establish the quantitative curves. After liquid-liquid extraction, VK1 trans- and cis- isomers in plasma samples were separated on a ChromCore C30 column (15 cm × 4.

View Article and Find Full Text PDF

Objective: To improve B field homogeneity in prostate MR imaging and spectroscopy using a custom-designed 16-channel external local shim coil array.

Methods: In vivo prostate imaging was performed in seven healthy volunteers (mean age: 40.7 years) without bowel preparation.

View Article and Find Full Text PDF

Interpretable machine learning model for characterizing magnetic susceptibility-based biomarkers in first episode psychosis.

Comput Methods Programs Biomed

September 2025

Department of Medical Imaging and Radiation Sciences, School of Primary and Allied Health Care, Faculty of Medicine, Nursing and Health Sciences, Monash University, Australia. Electronic address:

Background And Purpose: Several studies have shown changes in neurochemicals within the deep-brain nuclei of patients with psychosis. These alterations indicate a dysfunction in dopamine within subcortical regions affected by fluctuations in iron concentrations. Quantitative Susceptibility Mapping (QSM) is a method employed to measure iron concentration, offering a potential means to identify dopamine dysfunction in these subcortical areas.

View Article and Find Full Text PDF

Skin safety of 233 nm far UV-C ex vivo and in vivo - Pilot study for evaluating different populations and multiple exposures.

J Photochem Photobiol B

September 2025

Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Center of Experimental and Applied Cutaneous Physiology, Department of Dermatology, Venereology and Allergology, Charitéplatz 1, 10117 Berlin, Germany. Electronic address: Joha

Nosocomial infections remain a major healthcare challenge, underlining the demand for antimicrobial technologies. Far UV-C (200-235 nm) has emerged as a safer alternative to traditional 254 nm UV-C for microbial reduction on skin and wounds but also in occupied spaces due to its strong germicidal properties and minimal skin penetration. However, studies on humans remain limited.

View Article and Find Full Text PDF

Coproporphyrin (CP)-I has emerged as a promising endogenous biomarker for investigating organic anion transporting polypeptide (OATP) 1B1/1B3-mediated drug-drug interactions. The precursor eliminated analytical (PEA) method selectively quantifies the endogenous CP-I that should be monitored, whereas the precursor oxidized analytical method quantifies the total CP-I concentration by converting all precursors into CP-I during the sample preparation process. Plasma concentrations of CP-I exhibited a greater magnitude of change in response to rifampicin treatment compared with its precursor in a previous monkey study.

View Article and Find Full Text PDF