Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Weak optical fields cause less damage to active cells and are easier to realize than traditional and tightly focused optical fields. While these fields are promising for biomedical science and particle manipulation applications, they lack a method for precise particle diffusion measurement because the weak fields cause the small changes in particle motion caused by weak fields. In this paper, we present a coaxial differential dynamic microscopy (CDDM) technique that uses a differential dynamic microscopy system, combined with an adjustable optical field. We use this technique to study Brownian motion of colloidal particles in weak optical fields. CDDM can quantitatively measure both the intensity and the pattern of the weak optical field and the diffusion coefficient of the particles. While the light paths of both the weak optical field and the illumination are coaxially incident on the sample cell, they remain independent. The optical field can be designed to have any pattern and adjusted to any intensity, while the measurements' sample illumination requirements are also satisfied. To verify the accuracy of the technique, we measured particle diffusion in weak Gaussian optical fields of different strengths. The diffusion coefficient was found to decrease with increasing field strength. These experimental results agree well with those results predicted using the Fokker-Planck equation and Euler algorithm simulations. This technique is expected to provide an efficient tool for research into particle manipulation by using weak optical fields, particularly for delicate systems, such as colloidal particles and biological cells.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.26.032083DOI Listing

Publication Analysis

Top Keywords

weak optical
24
optical field
20
optical fields
20
differential dynamic
12
dynamic microscopy
12
optical
10
weak
9
coaxial differential
8
brownian motion
8
fields
8

Similar Publications

Comparative Validation of MOPTIM MRT-200 Refraction Device with 2WIN and Retinomax.

Clin Ophthalmol

September 2025

Alaska Blind Child Discovery, Alaska Children's EYE & Strabismus, Anchorage, Alaska, 99508, USA.

Background: Portable sphero-cylinder refraction is useful for remote medical missions and self-checking. A novel, inexpensive, handheld optical scope with an internal vision chart and adjustable diopter lens, called the Moptim MRT-200, was therefore validated.

Methods: Young, capable patients from a pediatric eye practice had dry refraction estimates with the Moptim MRT-200, Adaptica 2WIN photoscreener, and Monocular Retinomax compared with actual refined retinoscopy.

View Article and Find Full Text PDF

[Cu(3-bph)(PABA)(HO)] () (3-bph = ,'-bis(3-pyridylmethylene)hydrazine and PABA = -amino benzoate) is a pyridyl-N bridging Cu coordination polymer, and PABA acts as a carboxylate-O donor forming a square pyramidal CuNO motif following a zigzag one-dimensional (1D) lattice. The shows weak antiferromagnetic coupling ( = -0.196(1) cm), and emission appears at 352 nm (λ = 293 nm), which is selectively quenched by Fe via the FRET mechanism.

View Article and Find Full Text PDF

A potential replacement that alleviates the shortcomings of the dominant light absorber materials used in solar photovoltaics has been synthesized, and its microstructural, electronic structure, and optical properties have been investigated. KCuS crystals were synthesized by the carbonate method. Transmission electron microscopy (TEM) established [010] as the growth direction of the needle-like monoclinic crystals.

View Article and Find Full Text PDF

Detection of micro- and nanoplastic particles at extremely low concentrations in complex matrices is a critical goal in environmental science and regulatory frameworks. Surface-enhanced Raman spectroscopy (SERS) offers unique advantages for detecting molecular species in such mixtures, relying solely on their characteristic fingerprints. However, its application for plastic particles has been constrained due to weak analyte-substrate interactions.

View Article and Find Full Text PDF

Background: Lung ischemia-reperfusion injury (LIRI) is a pathological condition characterized by aggravated oxidative-inflammatory tissue damage that occurs upon blood flow restoration after ischemia. LIRI can lead to severe complications, including primary graft dysfunction in lung transplants and multi-organ failure. However, current treatments remain limited.

View Article and Find Full Text PDF