Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objectives: Parameter maps based on wavelet-transform post-processing of dynamic perfusion data offer an innovative way of visualizing blood vessels in a fully automated, user-independent way. The aims of this study were (i) a proof of concept regarding wavelet-based analysis of dynamic susceptibility contrast (DSC) MRI data and (ii) to demonstrate advantages of wavelet-based measures compared to standard cerebral blood volume (CBV) maps in patients with the initial diagnosis of glioblastoma (GBM).

Methods: Consecutive 3-T DSC MRI datasets of 46 subjects with GBM (mean age 63.0 ± 13.1 years, 28 m) were retrospectively included in this feasibility study. Vessel-specific wavelet magnetic resonance perfusion (wavelet-MRP) maps were calculated using the wavelet transform (Paul wavelet, order 1) of each voxel time course. Five different aspects of image quality and tumor delineation were each qualitatively rated on a 5-point Likert scale. Quantitative analysis included image contrast and contrast-to-noise ratio.

Results: Vessel-specific wavelet-MRP maps could be calculated within a mean time of 2:27 min. Wavelet-MRP achieved higher scores compared to CBV in all qualitative ratings: tumor depiction (4.02 vs. 2.33), contrast enhancement (3.93 vs. 2.23), central necrosis (3.86 vs. 2.40), morphologic correlation (3.87 vs. 2.24), and overall impression (4.00 vs. 2.41); all p < .001. Quantitative image analysis showed a better image contrast and higher contrast-to-noise ratios for wavelet-MRP compared to conventional perfusion maps (all p < .001).

Conclusions: wavelet-MRP is a fast and fully automated post-processing technique that yields reproducible perfusion maps with a clearer vascular depiction of GBM compared to standard CBV maps.

Key Points: • Wavelet-MRP offers high-contrast perfusion maps with a clear delineation of focal perfusion alterations. • Both image contrast and visual image quality were beneficial for wavelet-MRP compared to standard perfusion maps like CBV. • Wavelet-MRP can be automatically calculated from existing dynamic susceptibility contrast (DSC) perfusion data.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00330-018-5892-2DOI Listing

Publication Analysis

Top Keywords

dynamic susceptibility
8
dsc mri
8
wavelet-mrp maps
8
maps calculated
8
wavelet-based reconstruction
4
reconstruction dynamic
4
susceptibility mr-perfusion
4
mr-perfusion method
4
method visualize
4
visualize hypervascular
4

Similar Publications

Crab shell polypeptides enhance calcium dynamics and osteogenic activity in osteoporosis.

Front Pharmacol

August 2025

Department of Genetics and Cell Biology, School of Basic Medicine, Qingdao University, Qingdao, Shandong, China.

Background: Osteoporosis (OP) is a chronic, systemic skeletal disorder characterized by progressive bone loss and microarchitectural deterioration, which increases fracture susceptibility and presents a challenging set of global healthcare problems. Current pharmacological interventions are limited by adverse effects, high costs, and insufficient long-term efficacy. Here, we identify snow crab shell-derived polypeptides (SCSP) as a potent osteoprotective agent.

View Article and Find Full Text PDF

Biomolecular dynamics in the microsecond-to-millisecond (µs-ms) timescale are linked to various biological functions, such as enzyme catalysis, allosteric regulation, and ligand recognition. In solution state NMR, Carr-Purcell-Meiboom-Gill (CPMG) relaxation dispersion experiments are commonly used to probe µs-ms timescale motions, providing detailed kinetic, thermodynamic, and mechanistic information at the atomic level. For investigating conformational dynamics in high-molecular-weight biomolecules, methyl groups serve as ideal probes due to their favorable relaxation properties, and C CPMG relaxation dispersion is widely employed for characterizing dynamics in selectively CH-labeled samples.

View Article and Find Full Text PDF

The rate of sudden unexpected death in epilepsy (SUDEP) is ~1 per 1000 patients each year. Terminal events reportedly involve repeated and prolonged apnea, suggesting a failure to autoresuscitate. To better understand the mechanisms and identify novel therapeutics, standardized tests to screen for autoresuscitation efficacy are needed in preclinical SUDEP.

View Article and Find Full Text PDF

Concurrent recording of electroencephalogram (EEG) and functional magnetic resonance imaging (fMRI) signals reveals cross-scale neurovascular dynamics crucial for explaining fundamental linkages between function and behaviors. However, MRI scanners generate artifacts for EEG detection. Despite existing denoising methods, cabled connections to EEG receivers are susceptible to environmental fluctuations inside MRI scanners, creating baseline drifts that complicate EEG signal retrieval from the noisy background.

View Article and Find Full Text PDF

Magnetic Excitations of a Nodally-Hybridized Heavy-Fermion SemiMetal: Application to CeNiSn.

J Phys Condens Matter

September 2025

Department of Physics, Temple University, Barton Hall, Philadelphia, PA 19122-6082, USA, Philadelphiaa, Pennsylvania, 19122, UNITED STATES.

We examine the magnetic excitations of an Anderson lattice model with a Vshaped pseudogap arising from nodal hybridization. The model produces a V-shaped pseudogap in the electronic density of states near the Fermi energy. It lies close to an antiferromagnetic quantum critical point and features lowdimensional Fermi surfaces, aligning with experimental observations of CeNiSn.

View Article and Find Full Text PDF