98%
921
2 minutes
20
Introduction: Interpretation of the 12‑lead Electrocardiogram (ECG) is normally assisted with an automated diagnosis (AD), which can facilitate an 'automation bias' where interpreters can be anchored. In this paper, we studied, 1) the effect of an incorrect AD on interpretation accuracy and interpreter confidence (a proxy for uncertainty), and 2) whether confidence and other interpreter features can predict interpretation accuracy using machine learning.
Methods: This study analysed 9000 ECG interpretations from cardiology and non-cardiology fellows (CFs and non-CFs). One third of the ECGs involved no ADs, one third with ADs (half as incorrect) and one third had multiple ADs. Interpretations were scored and interpreter confidence was recorded for each interpretation and subsequently standardised using sigma scaling. Spearman coefficients were used for correlation analysis and C5.0 decision trees were used for predicting interpretation accuracy using basic interpreter features such as confidence, age, experience and designation.
Results: Interpretation accuracies achieved by CFs and non-CFs dropped by 43.20% and 58.95% respectively when an incorrect AD was presented (p < 0.001). Overall correlation between scaled confidence and interpretation accuracy was higher amongst CFs. However, correlation between confidence and interpretation accuracy decreased for both groups when an incorrect AD was presented. We found that an incorrect AD disturbs the reliability of interpreter confidence in predicting accuracy. An incorrect AD has a greater effect on the confidence of non-CFs (although this is not statistically significant it is close to the threshold, p = 0.065). The best C5.0 decision tree achieved an accuracy rate of 64.67% (p < 0.001), however this is only 6.56% greater than the no-information-rate.
Conclusion: Incorrect ADs reduce the interpreter's diagnostic accuracy indicating an automation bias. Non-CFs tend to agree more with the ADs in comparison to CFs, hence less expert physicians are more effected by automation bias. Incorrect ADs reduce the interpreter's confidence and also reduces the predictive power of confidence for predicting accuracy (even more so for non-CFs). Whilst a statistically significant model was developed, it is difficult to predict interpretation accuracy using machine learning on basic features such as interpreter confidence, age, reader experience and designation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jelectrocard.2018.08.007 | DOI Listing |
BMC Psychiatry
September 2025
Department of Cognitive Neuroscience, Faculty of Biology, Bielefeld University, Bielefeld, Germany.
Obsessive-compulsive disorder (OCD) is a chronic and disabling condition affecting approximately 3.5% of the global population, with diagnosis on average delayed by 7.1 years or often confounded with other psychiatric disorders.
View Article and Find Full Text PDFBMC Musculoskelet Disord
September 2025
Department of Clinical Sciences at Danderyds Hospital, Department of Orthopedic Surgery, Karolinska Institutet, Stockholm, 182 88, Sweden.
Background: This study evaluates the accuracy of an Artificial Intelligence (AI) system, specifically a convolutional neural network (CNN), in classifying elbow fractures using the detailed 2018 AO/OTA fracture classification system.
Methods: A retrospective analysis of 5,367 radiograph exams visualizing the elbow from adult patients (2002-2016) was conducted using a deep neural network. Radiographs were manually categorized according to the 2018 AO/OTA system by orthopedic surgeons.
Eye (Lond)
September 2025
Genetics Laboratory, Metropolitan South Clinical Laboratory, Bellvitge University Hospital, Institut d'Investigació Biomèdica de Bellvitge (IDIBELL), L'Hospitalet de Llobregat, Barcelona, Spain.
Background: Inherited retinal dystrophies (IRDs) are a genetically heterogeneous group of conditions, with approximately 40% of cases remaining unresolved after initial genetic testing. This study aimed to assess the impact of a personalised genomic approach integrating whole-exome sequencing (WES) reanalysis, whole-genome sequencing (WGS), customised gene panels and functional assays to improve diagnostic yield in unresolved cases.
Subjects/methods: We retrospectively reviewed a cohort of 597 individuals with IRDs, including 525 probands and 72 affected relatives.
J Chem Inf Model
September 2025
Department of Chemistry and Biochemistry, University of Arizona, Tucson, Arizona 85721-0041, United States.
The development of low-cost, high-performance materials with enhanced transparency in the long-wavelength infrared (LWIR) region (800-1250 cm/8-12.5 μm) is essential for advancing thermal imaging and sensing technologies. Traditional LWIR optics rely on costly inorganic materials, limiting their broader deployment.
View Article and Find Full Text PDFMed Eng Phys
October 2025
Biomedical Device Technology, Istanbul Aydın University, Istanbul, 34093, Istanbul, Turkey. Electronic address:
Deep learning approaches have improved disease diagnosis efficiency. However, AI-based decision systems lack sufficient transparency and interpretability. This study aims to enhance the explainability and training performance of deep learning models using explainable artificial intelligence (XAI) techniques for brain tumor detection.
View Article and Find Full Text PDF