Article Abstract

Objectives: To evaluate the reliability of consensus-based ultrasound (US) definitions of elementary components of enthesitis in spondyloarthritis (SpA) and psoriatic arthritis (PsA) and to evaluate which of them had the highest contribution to defining and scoring enthesitis.

Methods: Eleven sonographers evaluated 40 entheses from five patients with SpA/PsA at four bilateral sites. Nine US elementary lesions were binary-scored: hypoechogenicity, thickened insertion, enthesophytes, calcifications, erosions, bone irregularities, bursitis and Doppler signal inside and around enthesis. Kappa statistics were used to evaluate reliability. Sonographers were also asked to state which lesions can be considered as inflammatory or structural and should be included in the final definition of enthesitis. Only the lesions, scored as present in at least 75% of the entheses considered as having an enthesitis, were included in the final definition.

Results: The prevalence of detected lesions was quite low except for enthesophytes (55%) and bone irregularities (54%). Reliability ranged from poor to good (the lowest for thickened enthesis (kappa 0.1 (95% CI 0 to 0.7)) and the highest for enthesophytes (kappa 0.6 (95% CI 0.5 to 0.7)). When adjusted for low prevalence, kappa values increased for all lesions, with the best result observed for detecting Doppler signal at insertion (0.9) and for bursitis (0.8). The US components included in the final definition were hypoechogenicity, increased thickness at enthesis, erosions and calcifications/enthesophytes and Doppler signal at insertion.

Conclusion: By using a consensus-based stepwise approach, a final reliable US score and definition of enthesitis in SpA/PsA were produced. Further studies are sought for implementing this score in clinical trials and practice.

Download full-text PDF

Source
http://dx.doi.org/10.1136/annrheumdis-2018-213609DOI Listing

Publication Analysis

Top Keywords

doppler signal
12
included final
12
reliability consensus-based
8
consensus-based ultrasound
8
enthesitis spondyloarthritis
8
psoriatic arthritis
8
evaluate reliability
8
bone irregularities
8
enthesis kappa
8
final definition
8

Similar Publications

Widefield acoustics heuristic: advancing microphone array design for accurate spatial tracking of echolocating bats.

BMC Ecol Evol

September 2025

Lehrstuhl für Zoologie, TUM School of Life Sciences, Technical University of Munich, Liesel-Beckmann Strasse 4, Freising, 85354, Germany.

Accurate three-dimensional localisation of ultrasonic bat calls is essential for advancing behavioural and ecological research. I present a comprehensive, open-source simulation framework-Array WAH-for designing, evaluating, and optimising microphone arrays tailored to bioacoustic tracking. The tool incorporates biologically realistic signal generation, frequency-dependent propagation, and advanced Time Difference of Arrival (TDoA) localisation algorithms, enabling precise quantification of both positional and angular accuracy.

View Article and Find Full Text PDF

Incarcerated or threatened bowel obstruction with suspected intestinal ischemia requires prompt surgical intervention. This retrospective case series, involving 8 patients undergoing emergency laparotomy, evaluated the feasibility of combining indocyanine green (ICG) fluorescence and Doppler ultrasound for intraoperative bowel viability assessment. Indocyanine green was injected intravenously.

View Article and Find Full Text PDF

TissueMosaic: Self-supervised learning of tissue representations enables differential spatial transcriptomics across samples.

Cell Syst

September 2025

Broad Institute of MIT and Harvard, Cambridge, MA 02142, USA; Data Sciences Platform, Broad Institute of MIT and Harvard, Cambridge, MA 02142, USA. Electronic address:

Spatial transcriptomics allows for the measurement of gene expression within the native tissue context. However, despite technological advancements, computational methods to link cell states with their microenvironment and compare these relationships across samples and conditions remain limited. To address this, we introduce Tissue Motif-Based Spatial Inference across Conditions (TissueMosaic), a self-supervised convolutional neural network designed to discover and represent tissue architectural motifs from multi-sample spatial transcriptomic datasets.

View Article and Find Full Text PDF

The human kidneys play a pivotal role in regulating blood pressure, water, and salt homeostasis, but assessment of renal function typically requires invasive methods. Deuterium metabolic imaging (DMI) is a novel, noninvasive technique for mapping tissue-specific uptake and metabolism of deuterium-labeled tracers. This study evaluates the feasibility of renal DMI at 7-Tesla (7T) to track deuterium-labeled tracers with high spatial and temporal resolution, aiming to establish a foundation for potential clinical applications in the noninvasive investigation of renal physiology and pathophysiology.

View Article and Find Full Text PDF

Rationale: Systemic sclerosis (SS) is an immune-mediated connective disease characterized by skin fibrosis, microvascular damage, and multisystem manifestations. One of the most important processes in connective tissue disorders is vasculitis. The clinical findings can differ when the disease is presented with an antineutrophil cytoplasmic antibody.

View Article and Find Full Text PDF