Article Abstract

Background: Perventricular and transcatheter device closures are performed for perimembranous ventricular septal defect (pmVSD) to reduce the surgical trauma of conventional surgical repair via median sternotomy. Few comparative studies have been conducted among these three procedures.

Methods: From June 2015 to May 2016, 247 patients with isolated pmVSD who had undergone perventricular or transcatheter device closure or conventional surgical repair were reviewed to compare these three procedures.

Results: The procedure success rate was similar in these three groups. There were a statistically significant difference in operative time, aortic cross-clamping time, duration of cardiopulmonary bypass (CPB), blood transfusion amount, and medical cost in these three groups. Meanwhile, postoperative mechanical ventilation time, duration of intensive care, and length of hospital stay were longer in surgical group than the other two groups. The surgical group required the longest incision. No significant difference was noted in major adverse events. There were different advantages and disadvantages in these three kinds of procedures.

Conclusions: Device closure may be alternative to conventional surgical repair for patients with isolated pmVSD. Perventricular device closure was the preferred procedure because it showed more maneuverable than transcatheter procedure with the same clinical result.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6300419PMC
http://dx.doi.org/10.5761/atcs.oa.18-00085DOI Listing

Publication Analysis

Top Keywords

device closure
20
surgical repair
16
transcatheter device
12
conventional surgical
12
perventricular device
8
repair median
8
median sternotomy
8
perimembranous ventricular
8
ventricular septal
8
septal defect
8

Similar Publications

Background: Patent foramen ovale (PFO) has been identified as a potential risk factor for cryptogenic stroke (CS). Although transesophageal echocardiography (TEE) is considered the gold standard for PFO detection, false-negative results remain a clinical concern, particularly in CS patients with high suspicion of PFO-related etiology.

Aims: To evaluate the clinical utility of transcatheter PFO exploration (TPFOE) in CS patients with negative TEE findings but high suspicion of PFO-related etiology.

View Article and Find Full Text PDF

Introduction: The ADHEAR is a non-surgical Bone Conduction Device (BCD) that makes use of an adhesive adapter. While clinical trials have demonstrated its efficacy with regards to audiological performance, safety and compliance, data on real-world paediatric cohorts is scarce.

Methods: This retrospective cohort study analysed data from paediatric patients fitted with ADHEAR at a tertiary centre between January 2017 and September 2024.

View Article and Find Full Text PDF

The authors present treatment of patients with spinal injury complicated by extensive multiple pressure sores. A comprehensive preoperative management was followed by staged surgical treatment. Advisability of deep bedsore closure with full-layer flaps and staged interventions was justified.

View Article and Find Full Text PDF

Outcomes of Left Atrial Appendage Patency After Device Closure Detected by Cardiac CT: A Meta-Analysis.

JACC Cardiovasc Imaging

September 2025

Department of Cardiothoracic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania, USA; UPMC Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA. Electronic address:

Background: Residual leaks are common after left atrial appendage occlusion (LAAO).

Objectives: The authors aimed to systematically evaluate the prognostic implications of residual left atrial appendage (LAA) patency and peridevice leaks (PDLs) detected by cardiac computed tomography (CT) following LAAO.

Methods: The authors used traditional meta-analytical methods and a Bayesian framework to assess the probability of increased risks associated with these residual leaks.

View Article and Find Full Text PDF

We describe a modified Park's stitch technique incorporating systematic free margin alignment to achieve complete elimination of aortic regurgitation in patients with a left ventricular assist device. The technique involves a two-step approach: first, free margin alignment of all three cusps using single interrupted 6-0 polypropylene sutures placed at the nodules of Arantius to achieve precise coaptation, followed by conventional Park's stitch using mattress sutures with autologous pericardial pledgets for central closure. The alignment sutures remain in place to provide reinforcement.

View Article and Find Full Text PDF