98%
921
2 minutes
20
Statement Of Problem: Denture tooth fracture may limit the longevity of dental prostheses. Whether the strength of the denture tooth material is affected by the denture processing technique is unclear.
Purpose: The purpose of this in vitro study was to investigate whether the denture processing technique affects the mechanical properties of denture tooth materials.
Material And Methods: Two denture processing techniques, injection and compression molding, were tested for 3 types of denture teeth: nanohybrid composite (NHC), interpenetrating network (IPN), and microfiller-reinforced polyacrylic (MRP). Denture teeth were processed by using an injection-molded resin or a compression-molded resin. Unprocessed denture teeth served as the control. After teeth were processed, they were sectioned into rectangular beams for 3-point bend testing (n=20 to 24). Elastic moduli were determined from load deflection and maximum stress from maximum bending load. The results were statistically analyzed by using 2-way ANOVA and multiple comparisons (α=.05).
Results: The processing technique and the type of denture tooth affected both the elastic modulus and the maximum stress. The injection-molded technique resulted in significantly higher (24% to 26%) elastic modulus for NHC and IPN (12% higher in MRP, but not statistically significant) and higher (12% to 17%) maximum stresses for IPN and MRP (3% lower in NHC, but not statistically significant). Compression-molded technique increased the elastic modulus of IPN and NHC by 10% to 17% (3% lower in MRP but not statistically significant), but maximum stresses were not statistically significantly different in any of the tested teeth. Regardless of processing, MRP teeth had the highest elastic modulus (8.0 to 9.2 GPa) but the lowest maximum stresses (97 to 124 MPa), whereas IPN teeth had the lowest elastic modulus (5.5 GPa) but high or highest maximum stress (171 to 192 MPa).
Conclusions: The injection-molded technique significantly increased the elastic modulus of NHC and IPN teeth and significantly increased the maximum stress of IPN teeth. The compression-molded technique did not significantly affect mechanical properties of denture teeth.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.prosdent.2017.10.025 | DOI Listing |
Colloids Surf B Biointerfaces
September 2025
School of Mechanical Engineering, Xinjiang University, Urumqi 830017, PR China; Institute of Bioadditive Manufacturing, Jiangxi University of Science and Technology, Nanchang 330013, PR China.
High-performance hydrogel biomaterials hold considerable promise for advanced wound care. However, the suboptimal mechanical properties of conventional hydrogel materials limit their practical application. In this study, Hyaluronic acid sodium salt (HA), xanthan gum (XG), and N-acryloyl-glycinamide (NAGA) hydrogels with porous structures were successfully fabricated using in-situ extrusion 3D printing technology, and a functionalization strategy involving tea polyphenol (TP) immersion was proposed to enhance material properties through additional hydrogen bonding.
View Article and Find Full Text PDFBiomater Adv
September 2025
Department of Plastic Surgery, Tongren Hospital of Wuhan University (Wuhan Third Hospital), Wuhan, Hubei, 430060, PR China. Electronic address:
Hemostatic intervention at the bleeding site during early-phase wound management plays a crucial role in reducing trauma-induced complications and mortality, while advanced wound dressings facilitate hemorrhage control, exudate management, and antimicrobial protection to promote optimal healing outcomes. To address these issues, we developed a multifunctional collagen/silk fibroin/Mg(OH)₂ (Col/SF/Mg(OH)₂) composite sponge combining enhanced mechanical strength, rapid hemostasis, and broad-spectrum antibacterial activity. The incorporation of silk fibroin (SF) through covalent crosslinking increased the elastic modulus by 4.
View Article and Find Full Text PDFProc Natl Acad Sci U S A
September 2025
Martin A. Fisher School of Physics, Brandeis University, Waltham, MA 02453.
Programmable self-assembly has recently enabled the creation of complex structures through precise control of the interparticle interactions and the particle geometries. Targeting ever more structurally complex, dynamic, and functional assemblies necessitates going beyond the design of the structure itself, to the measurement and control of the local flexibility of the intersubunit connections and its impact on the collective mechanics of the entire assembly. In this study, we demonstrate a method to infer the mechanical properties of multisubunit assemblies using cryogenic electron microscopy (cryo-EM) and RELION's multi-body refinement.
View Article and Find Full Text PDFLangmuir
September 2025
Process Engineering in Life Science Engineering, HTW Berlin, Wilhelminenhofstraße 75 A, 12459 Berlin, Germany.
Pickering emulsions (PEs), where water-in-oil (w/o) droplets are stabilized by nanoparticles (NPs), offer a promising platform for biocatalysis by providing a large interfacial area crucial for efficient substrate conversion. While several lipase catalyzed reactions in PEs have been demonstrated, the exact interfacial structure is unknown. This study focuses on the interfacial network formed by NPs and lipase (CRL) at the octanol/water-interface by varying pH and NP charge.
View Article and Find Full Text PDFZhonghua Yan Ke Za Zhi
September 2025
Department of Ophthalmology, The Third Xiangya Hospital, Central South University, Changsha 410013, China.
To explore the effects of aging on the stiffness of human scleral fibroblast (HSF) and the remodeling of the extracellular matrix. This experimental study was conducted from January 2022 to June 2024. HSFs were cultured, and after cell passage, β-galactosidase staining was conducted.
View Article and Find Full Text PDF