98%
921
2 minutes
20
A precision PGC demodulation for homodyne interferometer modulated with a combined sinusoidal and triangular signal is proposed. Using a triangular signal as additional modulation, a continuous phase-shifted interference signal for ellipse fitting is generated whether the measured object is in static or moving state. The real-time ellipse fitting and correction of the AC amplitudes and DC offsets of the quadrature components in PGC demodulation can be realized. The merit of this modulation is that it can eliminate thoroughly the periodic nonlinearity resulting from the influences of light intensity disturbance, the drift of modulation depth, the carrier phase delay, and non-ideal performance of the low pass filters in the conversional PGC demodulation. The principle and realization of the signal processing with the combined modulation signal are described in detail. The experiments of accuracy and rate evaluations of ellipse fitting, nanometer, and millimeter displacement measurements were performed to verify the feasibility of the proposed demodulation. The experimental results show that the elliptical parameters of the quadrature components can be achieved precisely in real time and nanometer accuracy was realized in displacement measurements.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/OE.26.004818 | DOI Listing |
Micromachines (Basel)
February 2025
The Key Laboratory of Instrumentation Science and Dynamic Measurement Ministry of Education, North University of China, Taiyuan 030051, China.
Demodulation of fiber optic Fabry-Pérot (F-P) acoustic sensors with high sensitivity and a large dynamic range continues to pose significant challenges. In this paper, we propose an advanced phase-generated carrier (PGC) demodulation algorithm, applied innovatively to membrane-free F-P acoustic sensors operating under high sound pressure. The algorithm optimizes acoustic demodulation results by adjusting the mixing phase delay, achieving the best signal to noise and distortion ratio (SINAD) and total harmonic distortion (THD) (<1%).
View Article and Find Full Text PDFWhen the microprobe sensor is faced with the demand of high-speed biaxial displacement measurement, due to the characteristics of phase generated carrier (PGC) technology, accompanying optical intensity modulation (AOIM) and unfavorable phase modulation depth (PMD) will bring about the tens of nanometer cyclic nonlinear errors, further hindering high-speed and high-precision measurement. Herein, a light source intensity stabilization system based on semiconductor optical amplifier (SOA) feedback control is achieved to eliminate the error caused by AOIM in the presence of high-frequency and large-amplitude laser modulation. Based on this, the reasons for large nonlinear errors in biaxial measurements and the inability to ensure the stability of the accuracy of multiple measurement axes are methodically examined, and an effective nonlinear error elimination methodology based on the normalized amplitude correction of active temperature scanning is proposed.
View Article and Find Full Text PDFA phase generated carrier (PGC) demodulation scheme is always accompanied by nonlinear errors. We propose a fusion of PGC differential and cross multiplying (PGC-DCM), geometric fitting, and arctangent (Atan) algorithms for fiber optic interferometric sensors to eliminate nonlinear errors. The output amplitude of the PGC-DCM algorithm is used to judge whether the Lissajous figure of quadrature signals is larger than 1/2 ellipse arc.
View Article and Find Full Text PDFOpt Express
January 2024
An improved phase generated carrier arctangent demodulation algorithm based on harmonic mixing and phase quadrature technology (PGC-Arctan-HP) is proposed in this paper, which can eliminate the effects of modulation depth shift, carrier phase delay, and light intensity disturbance (LID) on the demodulation results. The simulation results are consistent with theoretical analysis, and indicate that the PGC-Arctan-HP algorithm can achieve optimal demodulation compared with other demodulation algorithms. The results of interferometric experiments show that the demodulated waveforms of the improved algorithm are relatively stable with an amplitude error of 0.
View Article and Find Full Text PDFPhase generated carrier (PGC) is widely applied in interferometric phase estimation for distance, vibration and velocity measurements. However, traditional PGC methods suffer from nonlinear effects, causing limitations to demodulation of signal. Modified PGC methods, such as ellipse fitting algorithm (EFA), resolves these issues, but usually requires additional phase shift.
View Article and Find Full Text PDF