Effect of a Paramagnetic Spin Label on the Intrinsically Disordered Peptide Ensemble of Amyloid-β.

Biophys J

Department of Chemical and Biomolecular Engineering, University of California, Berkeley, Berkeley, California; Department of Chemistry, University of California, Berkeley, Berkeley, California; Department of Bioengineering, University of California, Berkeley, Berkeley, California; Pitzer Center for

Published: September 2017


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Paramagnetic relaxation enhancement is an NMR technique that has yielded important insight into the structure of folded proteins, although the perturbation introduced by the large spin probe might be thought to diminish its usefulness when applied to characterizing the structural ensembles of intrinsically disordered proteins (IDPs). We compare the computationally generated structural ensembles of the IDP amyloid-β42 (Aβ42) to an alternative sequence in which a nitroxide spin label attached to cysteine has been introduced at its N-terminus. Based on this internally consistent computational comparison, we find that the spin label does not perturb the signature population of the β-hairpin formed by residues 16-21 and 29-36 that is dominant in the Aβ42 reference ensemble. However, the presence of the tag induces a strong population shift in a subset of the original Aβ42 structural sub-populations, including a sevenfold enhancement of the β-hairpin formed by residues 27-31 and 33-38. Through back-calculation of NMR observables from the computational structural ensembles, we show that the structural differences between the labeled and unlabeled peptide would be evident in local residual dipolar couplings, and possibly differences in homonuclear H-H nuclear Overhauser effects (NOEs) and heteronuclear H-N NOEs if the paramagnetic contribution to the longitudinal relaxation does not suppress the NOE intensities in the real experiment. This work shows that molecular simulation provides a complementary approach to resolving the potential structural perturbations introduced by reporter tags that can aid in the interpretation of paramagnetic relaxation enhancement, double electron-electron resonance, and fluorescence resonance energy transfer experiments applied to IDPs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5611636PMC
http://dx.doi.org/10.1016/j.bpj.2017.06.067DOI Listing

Publication Analysis

Top Keywords

spin label
12
structural ensembles
12
intrinsically disordered
8
paramagnetic relaxation
8
relaxation enhancement
8
β-hairpin formed
8
formed residues
8
structural
6
paramagnetic
4
paramagnetic spin
4

Similar Publications

Three antileishmanial compounds incorporating a butylated hydroxytoluene (BHT) moiety and an acrylate-based Michael acceptor scaffold were rationally designed from the lead structures LQFM064 and LQFM332, which feature a chalcone-derived core. Their activities against Leishmania (L.) amazonensis were evaluated.

View Article and Find Full Text PDF

Background: Hyperthermia (HT), while a cancer treatment approach, isn't always effective alone. Therefore, identifying hyperthermia enhancers is crucial. We demonstrated that Mito-TEMPO ([2-[(1-Hydroxy-2,2,6,6-tetramethylpiperidin-4-yl) amino]-2-oxoethyl]-triphenylphosphanium, MT) acts as a potent thermosensitizer, promoting cell death in human cervical cancer (HeLa) cells.

View Article and Find Full Text PDF

Introduction: Biofeedback is a non-pharmacological treatment option valued for its minimal risk of adverse events and offers a safe alternative for individuals seeking preventive care for migraine. Despite level A evidence for migraine prevention, biofeedback treatment is still unavailable to most patients. We developed a novel medical device (Cerebri) for multimodal biofeedback treatment that omits the need for healthcare personnel involvement.

View Article and Find Full Text PDF

Functional Imaging in Alzheimer's Disease: A Systematic Review and Meta-Analysis of ASL-MRI and FDG-PET.

J Neuroimaging

September 2025

Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins Medical Institution, Baltimore, Maryland, USA.

Background: Alzheimer's disease (AD) and mild cognitive impairment (MCI) are two common conditions associated with cognitive decline. With global dementia cases rising, identifying the most accurate imaging method for diagnosis is essential.

Methods: Following Preferred Reporting Items for Systematic review and Meta-Analysis Protocols, we systematically reviewed studies utilizing arterial spin labeling magnetic resonance imaging (ASL-MRI) and [18F]-2-fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) for neurodegenerative disorders.

View Article and Find Full Text PDF

Revealing the sensitivity of methyl tunneling towards local environment changes with quantum-rotor EPR spectroscopy.

J Magn Reson

August 2025

ETH Zurich, Department of Chemistry and Applied Biosciences, Vladimir-Prelog-Weg 2, Zurich, 8093, Switzerland.

Methyl rotors have potential as local environment probes because their rotation barrier is sensitive to hindering interactions with the nearby surrounding. Quantum-rotor electron paramagnetic resonance (EPR) measurements allow access to this local environment information of the methyl rotor if it is coupled to an electron spin. This is the case for commonly used nitroxide-based spin-labels, where electron spin echo envelope modulation (ESEEM) signals exhibit two contributions on different time scales at low temperatures.

View Article and Find Full Text PDF