Comparison of postoperative visual quality after SMILE and LASEK for high myopia: A 1-year outcome.

PLoS One

Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, People's Republic of China.

Published: October 2017


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: To compare the 1-year outcome of visual quality after laser-assisted subepithelial keratomileusis (LASEK) and femtosecond laser-assisted small incision lenticule extraction (SMILE) for high myopia correction.

Materials And Methods: This prospective, comparative study included 24 eyes of 24 patients in the LASEK group, with a mean spherical equivalent (SE) of -7.59 ± 1.32 diopters, and 26 eyes of 26 patients in the SMILE group, with a mean SE of -7.91 ± 1.08 diopters. Visual acuity, corneal topography, contrast sensitivity (CS), and wavefront aberrations were recorded preoperatively and compared with postoperative measurements. Objective scatter index (OSI) and modulation transfer function (MTF) cut-off frequency were measured 1 year postoperatively.

Results: One year postoperatively, the two groups demonstrated no significant difference in the CS at all spatial frequencies. The increments of higher-order aberrations (HOAs) (HOA = 0.583 ± 0.210 μm), including spherical aberration (SA) (SA = 0.546 ± 0.249 μm), were higher (P < 0.05) in the LASEK group than those in the SMILE group (HOA = 0.451 ± 0.143 μm; SA = 0.450 ± 0.340 μm) after surgery. There were no significant differences in the increments of coma and trefoil aberrations between the two groups. The OSI and MTF cut-off frequency exhibited no significant differences between the two groups postoperatively. No vision-threatening complications were noted at any stage in either group.

Conclusions: Both LASEK and SMILE are safe and effective surgical options for the correction of high myopia. SMILE has a lower HOAs and SA induction rate 1 year postoperatively.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5542625PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0182251PLOS

Publication Analysis

Top Keywords

high myopia
12
visual quality
8
1-year outcome
8
eyes patients
8
lasek group
8
smile group
8
mtf cut-off
8
cut-off frequency
8
year postoperatively
8
smile
6

Similar Publications

Clinical Relevance: Good vision is critical for childhood development and education. Pre-school vision screening is important for early detection and treatment of visual problems, and prevention of life-long vision loss.

Background: The aim of this study was to determine the prevalence of vision impairment (VI) and refractive error (RE) in rural Nepalese children under five years of age.

View Article and Find Full Text PDF

Purpose: To analyze the effects of ablation interruption on ablation depths and clinical refractive outcomes to characterize the impact of ambient temperature changes and ablation interruption on ocular surface temperature (OST) during excimer laser ablation.

Methods: This prospective study was conducted on laser ablations in polymethylmethacrylate (PMMA) plates and porcine corneas to simulate laser in situ keratomileusis (LASIK) treatments using the EX500 laser (Alcon Laboratories, Inc) at ambient temperatures of 18, 20, and 22 °C. Ablation interruption was performed for 1, 2, 3, 4, and 5 seconds at the 10th second of the treatment of -9.

View Article and Find Full Text PDF

Purpose: To compare postoperative vault measurements between horizontal and vertical fixation of the Implantable Collamer Lens (ICL) (KS-AquaPORT; STAAR Surgical) when its size is determined using the KS formula.

Methods: This retrospective study analyzed 2,343 eyes from 1,275 patients who underwent myopic ICL implantation. Pre-operative anterior segment optical coherence tomography (AS-OCT) (CASIA 2; Tomey Corporation) was performed in both horizontal and vertical orientations.

View Article and Find Full Text PDF

Purpose: To evaluate intraocular lens (IOL) power calculation of a non-diffractive extended depth of focus (EDOF) IOL after myopic laser in situ keratomileusis (LASIK) without historical data.

Methods: In this consecutive case series, patients who had undergone lens surgery with implantation of a non-diffractive EDOF IOL after myopic laser in situ keratomileusis (LASIK) at the Department of Ophthalmology, University Hospital Frankfurt, Frankfurt, Germany, were included. Preoperative assessments included biometry and tomography using Scheimpflug technology (Pentacam; Oculus Optikgeräte GmbH).

View Article and Find Full Text PDF

Purpose: This study aimed to investigate the prevalence, healthcare resource utilization (HCRU) and associated costs of myopia in Germany, comparing mild/moderate and high myopia across various age groups using real-world data.

Methods: A retrospective cross-sectional study was conducted using data from the WIG2 benchmark database. Patients with a diagnosis of myopia (ICD-10-GM H52.

View Article and Find Full Text PDF