98%
921
2 minutes
20
Introduction: While only 15-20% of patients with foot and ankle injuries presenting to urgent care centers have clinically significant fractures, most undergo radiography. We examined the impact of electronic point-of-care clinical decision support (CDS) on adherence to the Ottawa Ankle Rules (OAR), as well as use and yield of foot and ankle radiographs in patients with acute ankle injury.
Methods: We obtained institutional review board approval for this randomized controlled study performed April 18, 2012-December 15, 2013. All ordering providers credentialed at an urgent care affiliated with a quaternary care academic hospital were randomized to either receive or not receive CDS, based on the OAR and integrated into the physician order-entry system, with feedback at the time of imaging order. If the patient met OAR low-risk criteria, providers were advised against imaging and could either cancel the order or ignore the alert. We identified patients with foot and ankle complaints via ICD-9 billing codes and electronic health records and radiology reports reviewed for those who were eligible. Chi-square was used to compare adherence to the OAR (primary outcome), radiography utilization rate and radiography yield of foot and ankle imaging (secondary outcomes) between the intervention and control groups.
Results: Of 14,642 patients seen at urgent care during the study period, 613 (4.2%, representing 632 visits) presented with acute ankle injury and were eligible for application of the OAR; 374 (59.2%) of these were seen by control-group providers. In the intervention group, CDS adherence was higher for both ankle (239/258=92.6% vs. 231/374=61.8%, p=0.02) and foot radiography (209/258=81.0% vs. 238/374=63.6%; p<0.01). However, ankle radiography use was higher in the intervention group (166/258=64.3% vs. 183/374=48.9%; p<0.01), while foot radiography use (141/258=54.6% vs. 202/374=54.0%; p=0.95) was not. Radiography yield was also higher in the intervention group (26/307=8.5% vs. 18/385=4.7%; p=0.04).
Conclusion: Clinical decision support, previously demonstrated to improve guideline adherence for high-cost imaging, can also improve guideline adherence for radiography - as demonstrated by increased OAR adherence and increased imaging yield.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5391900 | PMC |
http://dx.doi.org/10.5811/westjem.2017.1.33053 | DOI Listing |
Cureus
August 2025
Orthopedics, College of Medicine, King Saud University, Riyadh, SAU.
Background: Gradual correction of lower-limb angular deformities using external fixators such as the Taylor Spatial Frame (TSF) is a well-established technique for addressing complex, multiplanar deformities. A common yet understudied adjunct to this method is the use of a distal tibio-fibular syndesmotic screw to stabilize the ankle mortise during correction. Despite being frequently practiced, the necessity and efficacy of this intervention remain unclear.
View Article and Find Full Text PDFActa Ortop Mex
September 2025
Universidade de Ribeirão Preto Campus Guarujá. Guarujá-SP, Brazil.
Talus is the second largest bone in the posterior region of the foot and participates in the talocrural (ankle), subtalar, and talonavicular joints. Talar fractures account for only one percent of all feet and ankle fractures, being the fracture of the medial tubercle of the posterior process of the talus an uncommon injury, caused by the rupture of the posterior talotibial ligament after dorsiflexion and traumatic pronation. Such fractures may not be radiographically evident, as described in this rare case of fracture of the medial tubercle of the posterior process of the talus with a satisfactory outcome without the need for surgical treatment.
View Article and Find Full Text PDFGait Posture
September 2025
Department of Anatomy and Medical Imaging, University of Auckland, Auckland, New Zealand.
Background: While the plantar fat pad is known for its role in shock absorption and plantar force distribution during weight-bearing activities, its impact on running biomechanics is not well understood.
Research Question: Does plantar fat pad thickness affect lower limb biomechanics and plantar pressure distribution during running in healthy adults?
Methods: This cross-sectional observational study involved fourteen participants (18-50 years) who ran at their preferred speed on a 10-meter walkway while lower limb kinematics and ground reaction forces were recorded using a motion capture system. Plantar pressure and force on the right foot were measured using a pressure platform.
Med Eng Phys
October 2025
Centre for Biomechanics and Rehabilitation Technologies, Staffordshire University, Stoke-On-Trent, UK; Reading Central PCN, Reading, UK.
Background: Drape-forming is a cost-effective method used worldwide to manufacture bespoke ankle foot orthoses (AFOs). It involves draping a heated polymer material sheet over a positive cast of the user's limb. Previous research has shown that the manual nature of drape-forming can influence the thickness of the final AFO and even lead to structures that are inadequately rigid to be clinically effective.
View Article and Find Full Text PDFFoot Ankle Int
September 2025
Department of Orthopaedic Surgery, Medical College of Wisconsin, Milwaukee, WI, USA.
Background: Glucagon-like peptide-1 receptor agonists (GLP-1 RAs) are increasingly used in management of type 2 diabetes mellitus (T2DM) and obesity. Beyond glycemic control, these agents may influence orthopaedic outcomes. This study aimed to assess the relationship between preoperative GLP-1 RA use and postoperative complications in T2DM patients undergoing operative ankle fracture repair.
View Article and Find Full Text PDF