Effect of airflow and material models on tissue displacement for surgical planning of pharyngeal airways in pediatric down syndrome patients.

J Mech Behav Biomed Mater

Department of Aerospace Engineering and Engineering Mechanics, University of Cincinnati, Cincinnati, OH, USA; Department of Otolaryngology - Head and Neck Surgery, University of Cincinnati Medical Center, Cincinnati, OH, USA. Electronic address:

Published: July 2017


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Pharyngeal narrowing in obstructive sleep apnea (OSA) results from flow-induced displacement of soft tissue. The objective of this study is to evaluate the effect of airflow parameters and material model on soft tissue displacement for planning surgical treatment in pediatric patients with OSA and Down syndrome (DS). Anatomically accurate, three-dimensional geometries of the pharynx and supporting tissue were reconstructed for one pediatric OSA patient with DS using magnetic resonance images. Six millimeters of adenoid tissue was virtually removed based on recommendations from the surgeon, to replicate the actual adenoidectomy. Computational simulations of flow-induced obstruction of the pharynx during inspiration were performed using patient-specific values of tissue elasticity for pre and post-operative airways. Sensitivity of tissue displacement to selection of turbulence model, variation in inspiratory airflow, nasal airway resistance and choice of non-linear material model was evaluated. The displacement was less sensitive to selection of turbulence model (10% difference) and more sensitive to airflow rate (20% difference) and nasal resistance (30% difference). The sensitivity analysis indicated that selection of Neo-Hookean, Yeoh, Mooney-Rivlin or Gent models would result in identical tissue displacements (less than 1% difference) for the same flow conditions. Change in pharyngeal airway resistance between the rigid and collapsible models was nearly twice for the pre-operative case as compared to the post-operative scenario. The tissue strain at the site of obstruction in the velopharyngeal airway was lowered by approximately 84% following surgery. Inclusion of tissue elasticity resulted in better agreement with the actual surgical outcome compared to a rigid wall assumption, thereby emphasizing the importance of pharyngeal compliance for guiding treatment in pediatric OSA patients.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmbbm.2017.03.007DOI Listing

Publication Analysis

Top Keywords

tissue displacement
12
tissue
10
soft tissue
8
material model
8
treatment pediatric
8
pediatric osa
8
tissue elasticity
8
selection turbulence
8
turbulence model
8
airway resistance
8

Similar Publications

Flexible suction-coagulation probe restores dexterity in robot-assisted surgery: bench-to-bedside evaluation.

Surg Endosc

September 2025

Department of Next Generation Endoscopic Intervention (Project ENGINE), Graduate School of Medicine, The University of Osaka, Suite 0802, BioSystems Bldg., 1-3, Yamadaoka, Suita, Osaka, 565-0871, Japan.

Objective: Rigid suction-coagulation probes constrain the wrist-like articulation that is central to robotic surgery. We therefore designed a 5-mm single-use flexible suction ball coagulator (flex-SBC) with a modified core design to restore dexterity and assessed its mechanical performance and early clinical feasibility, including the effect of the common robotic gripping strategies on suction flow.

Methods: Preclinical.

View Article and Find Full Text PDF

Statement Of Problem: Although custom temporomandibular joint (TMJ) prostheses manufactured via computer-aided design and manufacturing (CAD-CAM) and produced through 3-dimensional (3D) printing or computer numerical control (CNC) allow for sagittal curvature adjustments in the glenoid fossa, their design remains unregulated by the Food and Drug Administration. Consequently, the geometry is determined largely by the engineer's discretion, with limited biomechanical evidence to guide these decisions. The lack of validation regarding how sagittal curvature influences joint stress distribution under various anatomical and functional conditions represents a gap in current knowledge that warrants investigation.

View Article and Find Full Text PDF

Subcutaneous enucleation of the radial neck in a Monteggia-like fracture: an exceptional variant.

Int J Surg Case Rep

August 2025

CHU Joseph Ravoahangy Andrianavalona, Service de Chirurgie Orthopédique et Traumatologique, 101 Tananarive, Madagascar.

Introduction And Importance: Monteggia lesions combine a fracture of the ulna with dislocation of the radial head. Monteggia-like variants add a radial head fracture. We report a unique Monteggia-like injury with a bifocal radial fracture and subcutaneous enucleation of the radial neck, which does not fit existing classifications.

View Article and Find Full Text PDF

Chronic wounds, particularly in diabetic patients, are characterized by prolonged inflammation, impaired angiogenesis, and delayed tissue regeneration. To address these challenges, the author developed a bioactive scaffold by incorporating quercetin nanoparticles (Qn) into a chitosan/silk fibroin (ChS) matrix, aiming to accelerate and enhance the wound healing process. Quercetin nanoparticles were synthesized via a solvent displacement method and incorporated into a ChS scaffold using a blending and freeze-drying technique.

View Article and Find Full Text PDF

Fibrin Sealant-Assisted Fixation of an Autologous Iliac Bone Graft in Orbital Floor Reconstruction.

J Craniofac Surg

September 2025

Division of Ophthalmic Plastic and Reconstructive Surgery, Sadik Eratik Eye Institute, Haydarpasa Numune Education and Research Hospital, University of Health Sciences.

Orbital floor fractures can lead to enophthalmos and diplopia, often requiring surgical intervention to restore orbital volume. Autologous iliac bone grafts are commonly used due to their biocompatibility and mechanical stability, but achieving adequate fixation remains a challenge. Traditional fixation methods, such as plates and screws, may introduce risks of foreign body reactions, graft displacement, and surgical morbidity.

View Article and Find Full Text PDF