98%
921
2 minutes
20
Purpose: The aim of this study was to develop and evaluate a method for measuring the cortical bone thickness from computed tomography (CT) scans with metallic implants and to assess the benefits of metal artefact removal software.
Methods: A previously validated technique based on the fitting of a cortical model was modified to also model metal structures when required. Cortical thickness measurements were taken over intact bone segments and compared with the corresponding contralateral bone segment. The evaluation dataset includes post-operative CT scans of a unipolar hemi-arthroplasty, a dynamic hip screw fixation, a bipolar hemi-arthroplasty, a fixation with cannulated screws and a total hip arthroplasty. All CT scans were analysed before and after processing with metal artefact removal software.
Results: Cortical thickness validity and accuracy were improved through the use of a modified metalwork-optimised model and metal artefact removal software. For the proximal femoral segments of the aforementioned cases, the cortical thickness was measured with a mean absolute error of 0.55, 0.39, 0.46, 0.53 and 0.69 mm. The hemi-pelvis produced thickness errors of 0.51, 0.52, 0.52, 0.47 and 0.67 mm, respectively.
Conclusions: The proposed method was shown to measure cortical bone thickness in the presence of metalwork at a sub-millimetre accuracy. This new technique might be helpful in assessing fracture healing near implants or fixation devices, and improve the evaluation of periprosthetic bone after hip replacement surgery.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5702383 | PMC |
http://dx.doi.org/10.1007/s11548-017-1539-z | DOI Listing |
Nucl Med Rev Cent East Eur
September 2025
Nuclear Medicine Research Center, Mashhad University of Medical Sciences, Mashhad, Iran, Islamic Republic Of.
A 37-year-old man presented with swelling and erythema in the left first toe after a prior trauma, suspicious for osteomyelitis. X-ray and computed tomography (CT) scans revealed a radiolucent lesion with cortical disruption. A 99mTc/tricine/HYNIC ubiquicidin 29-41 (UBI) scintigraphy showed increased uptake but a non-accumulative time-activity curve, indicating a false positive for infection.
View Article and Find Full Text PDFJ Mech Behav Biomed Mater
September 2025
Center for Applied Biomechanics, University of Virginia, 4040 Lewis and Clark Drive, Charlottesville, VA, 22911, United States.
Seatbelt-induced pelvic iliac wing injuries have been observed since the 1970s, but only recently has there been quantification of fracture tolerance and injury risk of the iliac wing. Previous studies have shown a wide variation in iliac wing fracture tolerance with no significant relationships to pelvis size, sex, or other factors. A weighted average bone density (BD) calculation of the entire iliac wing produced the best predictive performance of fracture tolerance in parametric (Weibull) survival models.
View Article and Find Full Text PDFBMC Oral Health
September 2025
Department of Oral and Maxillofacial Surgery, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Berlin, Germany.
Background: A modified pull-through approach represents a promising treatment strategy to access tumors in the posterior oral cavity. The design of the wedge osteotomy plays a key role in preserving postoperative mechanical stability while enabling surgical access. However, the optimal osteotomy design to reduce fracture risk remains unclear.
View Article and Find Full Text PDFMed Eng Phys
October 2025
Centre for Simulation in Bioengineering, Biomechanics and Biomaterials (CS3B), Department of Mechanical Engineering, School of Engineering of Bauru, São Paulo State University (UNESP), Bauru, São Paulo, Brazil. Electronic address:
This study aimed to evaluate the near-cortical over-drilling technique on the mechanical behaviour of bone-plate constructs in a rabbit transverse femoral fracture. In vitro biomechanical testing and finite element (FE) models were used for analyses. Rabbits' bones (n = 14) were divided into two groups: G1 - without near-cortical over-drilling, and G2 - with near-cortical over-drilling.
View Article and Find Full Text PDFGlobal Spine J
September 2025
Department of Spinal Surgery, Zhucheng People's Hospital, Zhucheng, China.
Study DesignRetrospective cohort study.ObjectivesUnilateral percutaneous kyphoplasty (PKP) is widely used to treat osteoporotic vertebral compression fractures (OVCF) in elderly patients. Cement leakage is the most common complication and may cause serious consequences.
View Article and Find Full Text PDF