X-ray diffraction is a common technique for determining crystal structures. The average time needed for the solution of a protein structure has been drastically reduced by a number of recent experimental and theoretical developments. Since high-throughput protein crystallography benefits from full automation of all steps that are carried out on a synchrotron beamline, an automatic crystal centring procedure is important for crystallographic beamlines. Fully automatic crystal alignment involves the application of optical methods to identify the crystal and move it onto the rotation axis and into the X-ray beam. Crystal recognition has complex dependencies on the illumination, crystal size and viewing angles due to effects such as local shading, inter-reflections and the presence of antifreezing elements. Here, a rapid procedure for crystal centring with multiple cameras using region segment thresholding is reported. Firstly, a simple illumination-invariant loop recognition and classification model is used by slicing a low-magnification loop image into small region segments, then classifying the loop into different types and aligning it to the beam position using feature vectors of the region segments. Secondly, an edge detection algorithm is used to find the crystal sample in a high-magnification image using region segment thresholding. Results show that this crystal centring method is extremely successful under fluctuating light states as well as for poorly frozen and opaque samples. Moreover, this crystal centring procedure is successfully integrated into the enhanced Blu-Ice data collection system at beamline BL17U1 at the Shanghai Synchrotron Radiation Facility as a routine method for an automatic crystal screening procedure.

Download full-text PDF

Source
http://dx.doi.org/10.1107/S160057751601451XDOI Listing

Publication Analysis

Top Keywords

crystal centring
20
automatic crystal
16
centring procedure
12
crystal
11
region segment
8
segment thresholding
8
region segments
8
centring
5
procedure
5
automatic
4

Similar Publications

High-pressure crystallographic data can be measured using a diamond anvil cell (DAC), which allows the sample to be viewed only along a cell vector which runs perpendicular to the diamond anvils. Although centring a sample perpendicular to this direction is straightforward, methods for centring along this direction often rely on sample focusing, measurements of the direct beam or short data collections followed by refinement of the crystal offsets. These methods may be inaccurate, difficult to apply or slow.

View Article and Find Full Text PDF

Single-crystal diffraction at the high-pressure Indo-Italian beamline Xpress at Elettra, Trieste.

J Synchrotron Radiat

January 2020

Elettra Sincrotrone Trieste ScPA, Strada Statale 14, km 163.5, Basovizza, 34149 Trieste, Italy.

In this study the first in situ high-pressure single-crystal X-ray diffraction experiments at Xpress, the Indo-Italian beamline of the Elettra synchrotron, Trieste (Italy), are reported. A description of the beamline experimental setup and of the procedures for single-crystal centring, data collection and processing, using diamond anvil cells, are provided. High-pressure experiments on a synthetic crystal of clinoenstatite (MgSiO), CaCO polymorphs and a natural sample of leucophoenicite [MnSiO(OH)] validated the suitability of the beamline experimental setup to: (i) locate and characterize pressure-induced phase transitions; (ii) solve ab initio the crystal structure of high-pressure polymorphs; (iii) perform fine structural analyses at the atomic scale as a function of pressure; (iv) disclose complex symmetry and structural features undetected using conventional X-ray sources.

View Article and Find Full Text PDF

Multi-position data collection and dynamic beam sizing: recent improvements to the automatic data-collection algorithms on MASSIF-1.

Acta Crystallogr D Struct Biol

May 2018

European Molecular Biology Laboratory, Grenoble Outstation, 71 Avenue des Martyrs, CS 90181, 38042 Grenoble, France.

Macromolecular crystallography is now a mature and widely used technique that is essential in the understanding of biology and medicine. Increases in computing power combined with robotics have not only enabled large numbers of samples to be screened and characterized but have also enabled better decisions to be taken on data collection itself. This led to the development of MASSIF-1 at the ESRF, the first beamline in the world to run fully automatically while making intelligent decisions taking user requirements into account.

View Article and Find Full Text PDF

The complex analysis of X-ray mesh scans for macromolecular crystallography.

Acta Crystallogr D Struct Biol

April 2018

European Synchrotron Radiation Facility, BP 220, 38043 Grenoble, France.

In macromolecular crystallography, mesh (raster) scans are carried out either as part of X-ray-based crystal-centring routines or to identify positions on the sample holder from which diffraction images can be collected. Here, the methods used in MeshBest, software which automatically analyses diffraction images collected during a mesh scan and produces a two-dimensional crystal map showing estimates of the dimensions, centre positions and diffraction qualities of each crystal contained in the mesh area, are presented. Sample regions producing diffraction images resulting from the superposition of more than one crystal are also distinguished from regions with single-crystal diffraction.

View Article and Find Full Text PDF

Synthesis and crystal structure of solvent-free dodecahydro closo-dodecaborate of nickel, NiBH.

Dalton Trans

April 2018

Department of Quantum Matter Physics, Laboratory of Crystallography, University of Geneva, Quai Ernest-Ansermet 24, CH-1211 Geneva, Switzerland.

Nickel closo-dodecaborate NiB12H12 was prepared by mechanosynthesis (ball milling) of mixtures of Na2B12H12 + NiCl2 followed by hydration and drying under dynamic vacuum. The crystal structures of hydrated and anhydrous closo-dodecaborates were characterized by temperature dependent synchrotron radiation X-ray powder diffraction, ab initio calculations, thermal analysis and infrared spectroscopy. Three different water containing complexes were found: a homoleptic octahedral complex in Ni(H2O)6B12H12 crystallizing in two different deformation variants of a complex centred closo-dodecaborate cube, and a heteroleptic octahedral complex in Ni(H2O)4B12H12 containing four water molecules and two hydrogens and centring also a deformed closo-dodecaborate cube.