Article Abstract

Purpose: To assess the frequencies and sites of surgical glove perforations in lower extremity fracture surgery and hip joint replacement (HJR) surgery. Additionally, we also studied the usefulness of an indicator system glove.

Materials And Methods: We assessed surgical glove perforations in 30 cases of lower extremity fracture surgery and 18 cases of HJR surgery conducted by one right handed 1st operator from April 2013 to July 2013. We assessed frequencies and sites of perforation in 152 gloves; 95 used in lower extremity fracture surgery and 57 used in HJR surgery. We studied the perforation rates and sites according to participants and operation types. Using the Biogel indicator system glove, which is well known as a fast indicator of glove perforation, we were also able to assess the time difference between operative participant detection of perforation and inspector nurse detection while observing in the operative field.

Results: There were 18 of 30 cases in lower extremity fracture surgeries and 12 of 18 cases in HJR surgeries which had more than one surgical glove perforation event. Of all 152 gloves used, perforation occurred in 15 of 57 gloves (26.3%) in HJR surgery and 23 of 95 gloves (24.2%) in lower extremity fracture surgery. Perforation occurred more frequently in operators than assistant doctors or scrub nurses. The most frequent perforation site was the second digit of the left hand. On average, the time difference between operative participant notice of perforation and inspector nurse notice of perforation was 20.6 seconds.

Conclusion: The perforation of surgical gloves happened in approximately one out of every four persons. Importantly, we noted a 37.0% prevalence of glove perforation in 1st operators. Considering that glove perforation is a critical factor responsible for intra-operative infection, surgeons must be conscious of the risk of surgical glove perforation and use double gloving regularly. Furthermore, indicator double gloving is recommended for fast detection of outer glove perforation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4972615PMC
http://dx.doi.org/10.5371/hp.2015.27.1.17DOI Listing

Publication Analysis

Top Keywords

lower extremity
24
extremity fracture
24
glove perforation
24
fracture surgery
20
perforation
16
surgical glove
16
hjr surgery
16
surgery
10
glove
9
perforation surgical
8

Similar Publications

Background: Lower extremity arterial disease is a prevalent vascular condition leading to ischemic symptoms and increased risk of cardiovascular events. Drug-eluting stents have improved outcomes by reducing restenosis, with sirolimus emerging as a promising alternative to paclitaxel due to its safer profile. This study evaluates the efficacy and safety of novel polymer-free Amphilimus formulation (Sirolimus + fatty acid) eluting self-expanding stent in the treatment of femoropopliteal disease in a real-world population.

View Article and Find Full Text PDF

Objective: To analyze and improve postoperative outcomes in patients with acute lower limb ischemia (ALLI) and previous reconstructive infrainguinal interventions.

Material And Methods: The authors analyzed postoperative outcomes after 54 repeated interventions in patients with thrombosis of common femoral artery bifurcation, deep femoral artery and non-functioning femoropopliteal (tibial) prosthesis.

Results: External-iliac-deep femoral replacement were performed in 28 (52%) patients, extended deep femoral artery repair - in 16 (29.

View Article and Find Full Text PDF

Objective: To compare 6- and 12-month results of femoral artery repair with xenopericardial and autologous venous patch in hybrid treatment of critical lower limb ischemia.

Material And Methods: A retrospective analysis included 60 patients with critical lower limb ischemia who underwent hybrid treatment (balloon angioplasty and stenting of iliac arteries and open reconstruction of femoral arteries). Patients were divided into 2 groups by 30 people depending on femoral artery repair (group 1 - autologous venous patch, group 2 - xenopericardial patch).

View Article and Find Full Text PDF

Background: This study aimed to evaluate the predictive value of combining the Padua score with D-dimer levels for identifying lower extremity deep vein thrombosis (DVT) in acute ischemic stroke (AIS) patients undergoing intravenous thrombolysis with alteplase.

Methods: This retrospective study analyzed clinical data from 632 AIS patients who received alteplase treatment at our hospital between September 2019 and October 2023. After applying strict inclusion and exclusion criteria, a total of 172 patients were included in the analysis: 35 patients in the DVT group and 137 patients in the non-DVT group.

View Article and Find Full Text PDF

Background: Lower extremity alignment in knee osteoarthritis (OA) is conventionally assessed using standing radiographs. However, symptoms often manifest during gait. Understanding dynamic alignment during gait may help characterize disease progression and inform treatment strategies.

View Article and Find Full Text PDF