Optic Nerve Head Measurements With Optical Coherence Tomography: A Phantom-Based Study Reveals Differences Among Clinical Devices.

Invest Ophthalmol Vis Sci

Division of Biomedical Physics Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, Food and Drug Administration, Silver Spring, Maryland, United States.

Published: July 2016


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: Optical coherence tomography (OCT) can monitor for glaucoma by measuring dimensions of the optic nerve head (ONH) cup and disc. Multiple clinical studies have shown that different OCT devices yield different estimates of retinal dimensions. We developed phantoms mimicking ONH morphology as a new way to compare ONH measurements from different clinical OCT devices.

Methods: Three phantoms were fabricated to model the ONH: One normal and two with glaucomatous anatomies. Phantoms were scanned with Stratus, RTVue, and Cirrus clinical devices, and with a laboratory OCT system as a reference. We analyzed device-reported ONH measurements of cup-to-disc ratio (CDR) and cup volume and compared them with offline measurements done manually and with a custom software algorithm, respectively.

Results: The mean absolute difference between clinical devices with device-reported measurements versus offline measurements was 0.082 vs. 0.013 for CDR and 0.044 mm3 vs. 0.019 mm3 for cup volume. Statistically significant differences between devices were present for 16 of 18 comparisons of device-reported measurements from the phantoms. Offline Cirrus measurements tended to be significantly different from those from Stratus and RTVue.

Conclusions: The interdevice differences in CDR and cup volume are primarily caused by the devices' proprietary ONH analysis algorithms. The three devices yield more similar ONH measurements when a consistent offline analysis technique is applied. Scan pattern on the ONH also may be a factor in the measurement differences. This phantom-based study has provided unique insights into characteristics of OCT measurements of the ONH.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4968925PMC
http://dx.doi.org/10.1167/iovs.15-18738DOI Listing

Publication Analysis

Top Keywords

clinical devices
12
onh measurements
12
cup volume
12
measurements
10
onh
9
optic nerve
8
nerve head
8
optical coherence
8
coherence tomography
8
phantom-based study
8

Similar Publications

Use of a novel zipper device for wound closure of cutaneous abscesses in pediatric outpatients: a case series.

Wounds

August 2025

Department of Day Surgery, Children's Hospital of Chongqing Medical University, National Clinical Research Center for Child Health and Disorders, Ministry of Education Key Laboratory of Child Development and Disorder, Chongqing, China; China International Science and Technology Coopera

Background: Current management of pediatric cutaneous abscesses involves either spontaneous healing by secondary intention or suturing through tertiary intention, which are often lengthy processes that cause discomfort and distress among children. As it is noninvasive and simple, a novel zipper device is widely used for the primary wound closure of surgical incisions.

Objective: To describe the effectiveness of novel zipper device use for pediatric cutaneous abscess wound closure in an outpatient context.

View Article and Find Full Text PDF

Background: Diabetic foot ulcers (DFUs) are a major clinical challenge, particularly among patients with refractory ulcers, that often lead to severe complications such as infection, amputation, and high mortality. Innovations supported by strong clinical evidence have the potential to improve healing outcomes, enhance quality of life, and reduce the economic burden on individuals and health care systems.

Objective: To describe the design of the concurrent optical and magnetic stimulation (COMS) therapy Investigational Device Exemption (IDE) study for refractory DFUs (MAVERICKS) trial.

View Article and Find Full Text PDF

The rapid evolution of digital tools in recent years after COVID-19 pandemic has transformed diagnostic and therapeutic practice in neurology. This shift has highlighted the urgent need to integrate digital competencies into the training of future specialists. Key innovations such as telemedicine, artificial intelligence, and wearable health technologies have become central to improving healthcare delivery and accessibility.

View Article and Find Full Text PDF

Generative AI in perioperative medicine and anesthesiology: ethical integration, educational innovation, and the future of clinical professionalism.

J Anesth

September 2025

Community Medicine Education Promotion Office, Faculty of Medicine, Kagawa University Ikenobe, 1750-1, Miki-Cho, Kagawa, 761-0793, Japan.

Generative artificial intelligence (AI) is rapidly transforming perioperative medicine, particularly anesthesiology, by enabling novel applications, such as real-time data synthesis, individualized risk prediction, and automated documentation. These capabilities enhance clinical decision-making, patient communication, and workflow efficiency in the operating room. In education, generative AI offers immersive simulations and tailored learning experiences that improve both technical skills and professional judgment.

View Article and Find Full Text PDF

Objective: Reduction of bleeding and prolonged air leak (>5 days) following major lung resection remains a challenge. Hemostasis and aerostasis devices can facilitate earlier pleural de-drainage and fast-track. Our objectives were to evaluate the efficacy of TenaTac (an elastic, adhering patch approved as a medical device) in reducing bleeding and prolonged air leak after major lung resection.

View Article and Find Full Text PDF