20

Article Abstract

Although plate fixation has advantages over other fixation methods for certain indications, it is rarely used in avian surgery, especially in birds that weigh less than 1000 g. Exceptionally small plating systems for these birds are required, which are relatively expensive and difficult to insert. To study avian fracture healing after repair using miniplates, we evaluated 2 steel miniplate systems in 27 pigeons ( Columba livia ) divided into 4 groups. In each pigeon, the left ulna and radius were transected and the ulna was repaired with a bone plate. In groups A and B, a 1.3-mm adaption plate was applied without and with a figure-of-eight bandage; in groups C and D, a 1.0-mm compression plate was applied without and with a bandage, respectively. Healing was evaluated with radiographs after 3, 14, and 28 days; flight tests were conducted after 14, 21, and 28 days; and the wing was macroscopically examined after euthanasia of birds on day 28. Fractures healed without bending or distortion of the plate in all 27 birds, and no significant differences in healing were found between treatment groups. At the end of the study, 23 pigeons (85.2%) showed good or very good flight ability. Results show the 1.3-mm adaption plate and the 1.0-mm compression plate meet the requirements for avian osteosynthesis and can be recommended for fracture repair of the ulna or other long bones in birds weighing less than 500 g. The application of a figure-of-eight bandage might be beneficial in fracture healing.

Download full-text PDF

Source
http://dx.doi.org/10.1647/2015-082DOI Listing

Publication Analysis

Top Keywords

miniplate systems
8
pigeons columba
8
columba livia
8
fracture healing
8
13-mm adaption
8
adaption plate
8
plate applied
8
figure-of-eight bandage
8
10-mm compression
8
compression plate
8

Similar Publications

Mandibular fractures, a common subset of maxillofacial trauma, have significant functional, esthetic, and psychological implications. Hence, 34 patients were divided into two groups: Group A (3D miniplates) and Group B (conventional miniplates). Results showed that both plating systems provided comparable outcomes in terms of occlusal correction, fracture stability, and radiographic healing by the third postoperative month, with no statistically significant differences.

View Article and Find Full Text PDF

Accuracy of Patient-Specific Osteosynthesis in Bimaxillary Surgery: Comparative Feasibility Analysis of Four- and Two-Miniplate Fixation.

J Pers Med

May 2025

Department of Oral and Maxillofacial Surgery, Expertcenter for Orthofacial Surgery, Martini Hospital Groningen, Van Swietenplein 1, 9728 NT Groningen, The Netherlands.

: Patient-specific osteosynthesis (PSO) plates, in combination with virtual surgical planning (VSP), have significantly improved the accuracy of orthognathic surgery. This study aimed to compare the surgical accuracy of two-plate versus four-plate fixation methods in Le Fort I osteotomies using PSO. : A retrospective cohort study was conducted on 21 patients who underwent maxilla-first bimaxillary surgery at a single centre in 2024.

View Article and Find Full Text PDF

Compare the accuracy and performance of two different types of CAD-CAM surgical guides for maxillary positioning in orthognathic surgery.

J Craniomaxillofac Surg

July 2025

Federal University of Pará, Augusto Corrêa, 01, Guamá, CEP: 66075-110, Belém, PA, Brazil; Oral and Maxillofacial Surgery and Traumatology, Irmandade da Santa Casa de Misericórdia de São Paulo, Brazil; Department of Oral and Bucomaxillofacial Surgery, Canada. Electronic address:

Three-dimensional computer-aided design/manufacturing (CAD/CAM) maxillary guides have been developed to enhance surgical predictability, reducing mandibular interference and improving planning accuracy, especially in asymmetrical cases. This study aimed to compare the accuracy of two types of CAD/CAM guides used for maxillary positioning in orthognathic surgery. In this retrospective cohort study, 38 patients who underwent bimaxillary orthognathic surgery by the same surgeon were divided into two groups.

View Article and Find Full Text PDF

Finite element analysis of various fixation patterns in mandible bone fracture.

Comput Methods Biomech Biomed Engin

March 2025

School of Physical Therapy and Graduate Institute of Rehabilitation Science, College of Medicine, Chang Gung University, Taoyuan, Taiwan.

Mandibular fractures are among the most serious injuries to the maxillofacial region, with controversy surrounding their diagnosis, classification, and management Fixation mini-plate systems are commonly used for treatment of mandibular fractures. Previous studies have examined plate configurations with various locking systems. However, the impact of plate thickness on the performance of unlocking screw mechanisms has not been investigated in the literature.

View Article and Find Full Text PDF

Background: Maxillofacial fractures, frequently arising from road traffic incidents, falls, and acts of interpersonal aggression, are a considerable public health issue, exhibiting diverse epidemiological patterns according to demographic factors. The application of miniplates for fracture stabilization is a recognized technique, with innovative methods such as 3D plate systems emerging. Nonetheless, consequences including infections and hardware malfunctions persist.

View Article and Find Full Text PDF