Background: Measurement of accurate attenuation of photon flux in tissue is important to obtain reconstructed images using single-photon emission computed tomography (SPECT). Computed tomography (CT) scanner provides attenuation correction data for SPECT as well as anatomic information for diagnostic purposes. Segmentation is a process of dividing an image into regions having similar properties such as gray level, color, texture, brightness, and contrast. Image segmentation is an important tool for evaluation of medical images. X-ray beam used in CT scan is poly-energetic; therefore, we have used a copper filter to remove the low energy X-rays for obtaining correct attenuation factor. Images obtained with and without filters were quantitatively evaluated by segmentation method to avoid human error.
Materials And Methods: Axial images of AAPM CT phantom were acquired with 3 mm copper filter (low intensity) and without copper filter (high intensity) using low-dose CT (140 kvp and 2.5 mA) of SPECT/CT system (Hawkeye, GE Healthcare). For segmentation Simulated Annealing Based Fuzzy c-means, algorithm is applied. Quantitative measurement of quality is done based on universal image quality index. Further, for the validation of attenuation correction map of filtered CT images, Jaszczak SPECT phantom was filled with 500 MBq of (99m)Tc and SPECT study was acquired. Low dose CT images were acquired for attenuation correction to be used for reconstruction of SPECT images. Another set of CT images were acquired after applying additional 3 mm copper filter. Two sets of axial SPECT images were reconstructed using attenuation map from both the CT images obtained without and with a filter.
Results And Conclusions: When we applied Simulated Annealing Based Fuzzy c-means segmentation on both the CT images, the CT images with filter shows remarkable improvement and all the six section of the spheres in the Jaszczak SPECT phantom were clearly visualized.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4815382 | PMC |
http://dx.doi.org/10.4103/0972-3919.178260 | DOI Listing |
Environ Sci Pollut Res Int
September 2025
Department of Chemistry Education, Farhangian University, P.O. Box 14665-889, Tehran, Iran.
This study introduces a back filter installed at the end of the exhaust pipe of city buses. The impact of the metal type used in its construction on the absorption of suspended particles and the reduction of sulfides in diesel engine exhaust gases is investigated. The back filter is constructed from three metals: copper, zinc, and nickel.
View Article and Find Full Text PDFObjectives: Cerebral angiography remains the gold standard for the diagnosis and endovascular management of cerebral aneurysms. Three-dimensional rotational angiography (3D-RA) provides superior anatomic resolution compared with conventional 2D imaging; however, it is associated with relatively high radiation exposure, raising specific concerns regarding the ocular lens dose. This study aims to evaluate the potential of copper (Cu) filtration for reducing radiation dose in 3D-RA.
View Article and Find Full Text PDFLuminescence
September 2025
Key Laboratory of Green Chemical Engineering and Technology of College of Heilongjiang Province, College of Materials Science and Chemical Engineering, Harbin University of Science and Technology, Harbin, P. R. China.
A novel pyrene-based fluorescent probe PYS was designed and synthesized for the sequential detection of Cu and picric acid (PA) under identical experimental conditions. In ethanol-HEPES buffer (V/V = 8:2, pH = 7.4), Cu was selectively detected by PYS through fluorescence enhancement with a binding constant of 7.
View Article and Find Full Text PDFRadiol Phys Technol
August 2025
Department of Respiratory Medicine and Infectious Disease, Graduate School of Medicine, Yamaguchi University, 1-1-1 Minami-Kogushi, Ube, Yamaguchi, 755-8505, Japan.
In plain chest radiography (CXR), automatic exposure control (AEC) is generally used to standardize image quality. In contrast, dynamic chest radiography (DCR) systems preliminarily require manual setting of tube current-time products (mAs value). Body mass index (BMI) of patients is one of the indexes to determine the mAs value; however, standardization is limited because the anatomical differences are not considered.
View Article and Find Full Text PDFRSC Adv
August 2025
Advanced Materials and Intelligent Technologies Higher Education and Industrial Cooperation Centre, University of Miskolc Miskolc H-3515 Hungary.
Microbial contamination in drinking water continues to be a significant global issue due to its direct effects on human health, particularly in areas with insufficient sanitation or deteriorating infrastructure. Conventional treatment systems frequently encounter challenges in fully eliminating pathogenic bacteria, underscoring the pressing necessity for innovative, energy-efficient filtration technology to ensure universal access to clean drinking water. In this regard, numerous reconsidered membrane technologies and filtration solutions have been developed and published recently.
View Article and Find Full Text PDF