Studies have been conducted to refine US Environmental Protection Agency, ASTM International, and Environment Canada standard methods for conducting 42-d reproduction tests with Hyalella azteca in water or in sediment. Modifications to the H. azteca method include better-defined ionic composition requirements for exposure water (i.e., >15 mg/L of chloride and >0.02 mg/L of bromide) and improved survival, growth, and reproduction with alternate diets provided as increased rations over time in water-only or whole-sediment toxicity tests. A total of 24 laboratories volunteered to participate in the present interlaboratory study evaluating the performance of H. azteca in 42-d studies in control sand or control sediment using the refined methods. Improved growth and reproduction of H. azteca was observed with 2 alternate diets of 1) ramped diatoms (Thalassiosira weissflogii) + ramped Tetramin or 2) yeast-cerophyll-trout chow (YCT) + ramped Tetramin, especially when compared with results from the traditional diet of 1.8 mg YCT/d. Laboratories were able to meet proposed test acceptability criteria and in most cases had lower variation in growth or reproduction compared with previous interlaboratory studies using the traditional YCT diet. Laboratory success in conducting 42-d H. azteca exposures benefited from adherence to several key requirements of the detailed testing, culturing, and handling methods. Results from the present interlaboratory study are being used to help revise standard methods for conducting 10-d to 42-d water or sediment toxicity exposures with H. azteca. Environ Toxicol Chem 2016;35:2439-2447. © 2016 SETAC.

Download full-text PDF

Source
http://dx.doi.org/10.1002/etc.3417DOI Listing

Publication Analysis

Top Keywords

interlaboratory study
12
methods conducting
12
water sediment
12
growth reproduction
12
conducting 10-d
8
10-d 42-d
8
42-d water
8
sediment toxicity
8
toxicity tests
8
tests hyalella
8

Similar Publications

Breaking the reproducibility barrier with standardized protocols for plant-microbiome research.

PLoS Biol

September 2025

Environmental Genomics and Systems Biology, Lawrence Berkeley National Laboratory, Berkeley, California, United States of America.

Inter-laboratory replicability is crucial yet challenging in microbiome research. Leveraging microbiomes to promote soil health and plant growth requires understanding underlying molecular mechanisms using reproducible experimental systems. In a global collaborative effort involving five laboratories, we aimed to help advance reproducibility in microbiome studies by testing our ability to replicate synthetic community assembly experiments.

View Article and Find Full Text PDF

Conventional one-dimensional gas chromatography methods for gasoline quality monitoring require separate analyses for different component classes, limiting analytical efficiency and unconventional additive detection. This study presents a comprehensive two-dimensional gas chromatography with flame ionization detection (GC × GC-FID) platform enabling simultaneous quantification of regulated components and rapid screening of unconventional additives in a single analytical run. The method achieved excellent agreement with ASTM standards and high repeatability for BTEX (benzene, toluene, ethylbenzene, and xylenes) and oxygenates in gasoline.

View Article and Find Full Text PDF

Introduction: Discrepancies in factor IX activity (FIX:C) measurements between one-stage clotting assays (OSAs) have been observed following infusion with recombinant factor IX extended half-life concentrates (EHL-rFIX) in the treatment of haemophilia B. These variations, primarily due to differences in activated partial thromboplastin time (APTT) reagents, complicate clinical decision-making.

Objectives: The aim of this study was to evaluate whether drug-specific calibrations for albumin-fused recombinant FIX (rFIX-FP) and Fc-fused recombinant FIX (rFIX-Fc) could reduce inter-reagent discrepancies.

View Article and Find Full Text PDF

Ki67 is a broadly available biomarker of proliferation with various approaches to its evaluation in breast cancer. The International Ki67 in Breast Cancer Working Group (IKWG) recommends calculating Ki67 globally across the tumor area, as this method offers high interobserver concordance. These recommendations have been integrated into many international breast cancer guidelines (ASCO, ESMO), yet there is no real-world data on if it improved inter-pathologists and inter-laboratory variability.

View Article and Find Full Text PDF

Digital PCR (dPCR) technology is widely utilized for various applications, including the quantification of gene mutations and copy number variations. Certified reference materials (CRMs) play a critical role in improving the comparability of dPCR results, establishing SI-traceable copy number concentration values for dPCR calibration remains a key challenge due to the limited availability of CRMs value-assigned by higher-order, independent methods. To tackle this issue, a linearized plasmid DNA reference material (RM) was developed and rigorously characterized through an interlaboratory comparison involving three national measurement institutes (NMIs) from China (NIM), South Korea (KRISS), and Japan (NMIJ).

View Article and Find Full Text PDF