98%
921
2 minutes
20
Purpose: The aim of this study was to assess the effect of applying ACR Lung-RADS in a clinical CT lung screening program on the frequency of positive and false-negative findings.
Methods: Consecutive, clinical CT lung screening examinations performed from January 2012 through May 2014 were retroactively reclassified using the new ACR Lung-RADS structured reporting system. All examinations had initially been interpreted by radiologists credentialed in structured CT lung screening reporting following the National Comprehensive Cancer Network's Clinical Practice Guidelines in Oncology: Lung Cancer Screening (version 1.2012), which incorporated positive thresholds modeled after those in the National Lung Screening Trial. The positive rate, number of false-negative findings, and positive predictive value were recalculated using the ACR Lung-RADS-specific positive solid/part-solid nodule diameter threshold of 6 mm and nonsolid (ground-glass) threshold of 2 cm. False negatives were defined as cases reclassified as benign under ACR Lung-RADS that were diagnosed with malignancies within 12 months of the baseline examination.
Results: A total of 2,180 high-risk patients underwent baseline CT lung screening during the study interval; no clinical follow-up was available in 577 patients (26%). ACR Lung-RADS reduced the overall positive rate from 27.6% to 10.6%. No false negatives were present in the 152 patients with >12-month follow-up reclassified as benign. Applying ACR Lung-RADS increased the positive predictive value for diagnosed malignancy in 1,603 patients with follow-up from 6.9% to 17.3%.
Conclusions: The application of ACR Lung-RADS increased the positive predictive value in our CT lung screening cohort by a factor of 2.5, to 17.3%, without increasing the number of examinations with false-negative results.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jacr.2015.12.009 | DOI Listing |
J Am Coll Radiol
March 2025
Department of Radiology, Harvard Medical School, Brigham and Women's Hospital, Boston, Massachusetts. Electronic address:
Objective: To assess adherence to ACR recommendations for managing incidental adrenal lesions detected on lung cancer screening (LCS) CT examinations.
Methods: We performed a retrospective analysis of all LCS CT examinations within our health care system from January 2015 to August 2023. We included CTs that were reported with Lung-RADS "S" modifier for a focal adrenal lesion.
J Am Coll Radiol
June 2025
Center for Statistical Sciences, Brown University School of Public Health, Providence, Rhode Island; Department of Epidemiology, Brown University School of Public Health, Providence, Rhode Island.
Purpose: Although lung cancer screening (LCS) with low-dose chest CT (LDCT) is recommended for high-risk populations, little is known about how clinical screening compares with research trials. We compared Lung CT Screening Reporting and Data System (Lung-RADS) scores between a nationally screened population from the ACR's LCS Registry (LCSR) and the National Lung Screening Trial (NLST).
Methods: This retrospective study included baseline LDCT examinations from the LCSR and NLST.
J Thorac Oncol
December 2024
Division of Medical Oncology, Duke Cancer Institute, Durham, North Carolina. Electronic address:
Chest
March 2024
Professor of Radiology & Internal Medicine and Associate Chief Clinical Officer for Diagnostics, Michigan Medicine/University of Michigan Medical School, Ann Arbor, Michigan; Clinical Information Management, University of Michigan Medical Group.
The American College of Radiology created the Lung CT Screening Reporting and Data System (Lung-RADS) in 2014 to standardize the reporting and management of screen-detected pulmonary nodules. Lung-RADS was updated to version 1.1 in 2019 and revised size thresholds for nonsolid nodules, added classification criteria for perifissural nodules, and allowed for short-interval follow-up of rapidly enlarging nodules that may be infectious in etiology.
View Article and Find Full Text PDFQuant Imaging Med Surg
November 2023
Centre for Medical Sciences-CISMed, University of Trento, Trento, Italy.
Background And Objective: In recent years, there has been a large-scale dissemination of guidelines in radiology in the form of Reporting & Data Systems (RADS). The use of iodinated contrast media (ICM) has a fundamental role in enhancing the diagnostic capabilities of computed tomography (CT) but poses certain risks. The scope of the present review is to summarize the current role of ICM only in clinical reporting guidelines for CT that have adopted the "RADS" approach, focusing on three specific questions per each RADS: (I) what is the scope of the scoring system; (II) how is ICM used in the scoring system; (III) what is the impact of ICM enhancement on the scoring.
View Article and Find Full Text PDF