Article Abstract

Objectives: The authors sought to generate a synthetic extracellular volume fraction (ECV) from the relationship between hematocrit and longitudinal relaxation rate of blood.

Background: ECV quantification by cardiac magnetic resonance (CMR) measures diagnostically and prognostically relevant changes in the extracellular space. Current methodologies require blood hematocrit (Hct) measurement-a complication to easy clinical application. We hypothesized that the relationship between Hct and longitudinal relaxation rate of blood (R1 = 1/T1blood) could be calibrated and used to generate a synthetic ECV without Hct that was valid, user-friendly, and prognostic.

Methods: Proof-of-concept: 427 subjects with a wide range of health and disease were divided into derivation (n = 214) and validation (n = 213) cohorts. Histology cohort: 18 patients with severe aortic stenosis with histology obtained during valve replacement. Outcome cohort: For comparison with external outcome data, we applied synthetic ECV to 1,172 consecutive patients (median follow-up 1.7 years; 74 deaths). All underwent CMR scanning at 1.5-T with ECV calculation from pre- and post-contrast T1 (blood and myocardium) and venous Hct.

Results: Proof-of-concept: In the derivation cohort, native R1blood and Hct showed a linear relationship (R(2) = 0.51; p < 0.001), which was used to create synthetic Hct and ECV. Synthetic ECV correlated well with conventional ECV (R(2) = 0.97; p < 0.001) without bias. These results were maintained in the validation cohort. Histology cohort: Synthetic and conventional ECV both correlated well with collagen volume fraction measured from histology (R(2) = 0.61 and 0.69, both p < 0.001) with no statistical difference (p = 0.70). Outcome cohort: Synthetic ECV related to all-cause mortality (hazard ratio 1.90; 95% confidence interval 1.55 to 2.31; for every 5% increase in ECV). Finally, we engineered a synthetic ECV tool, generating automatic ECV maps during image acquisition.

Conclusions: Synthetic ECV provides validated noninvasive quantification of the myocardial extracellular space without blood sampling and is associated with cardiovascular outcomes.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcmg.2015.11.008DOI Listing

Publication Analysis

Top Keywords

synthetic ecv
24
ecv
14
synthetic
10
synthetic extracellular
8
extracellular volume
8
generate synthetic
8
volume fraction
8
longitudinal relaxation
8
relaxation rate
8
extracellular space
8

Similar Publications

Effect of age and sex on cardiac magnetic resonance native T1 mapping and synthetic extracellular volume.

Int J Cardiol

August 2025

Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland; Department of Nuclear Medicine, University Hospital Zurich, Zurich, Switzerland; Center for Molecular Cardiology, University of Zurich, Schlieren, Switzerland.

Background: Cardiac magnetic resonance (CMR) using native T1 mapping and extracellular volume (ECV) fraction is the gold standard for noninvasive detection of diffuse myocardial fibrosis. Previous studies indicate that women tend to have higher native T1 and ECV values than men, but how these parameters evolve with cardiac aging remains unclear.

Methods And Results: Relations between age, sex, and native T1 and synthetic ECV were assessed in 306 individuals (mean age 45 ± 18 years; 47.

View Article and Find Full Text PDF

Cardiac magnetic resonance (CMR) is a key modality for non-invasive extracellular volume (ECV) quantification, typically requiring venous hematocrit (Hct). However, fluctuations in Hct can affect accuracy. This study aimed to develop a synthetic Hct model integrating age, sex, and pre- and post-contrast blood pool T1 values, calibrated against an optimized venous Hct reference.

View Article and Find Full Text PDF

Synthetic hematocrit-based extracellular volume quantification from photon-counting CT: Validation against MRI and systematic bias correction.

Eur J Radiol

October 2025

Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, USA; Department of Diagnostic and Interventional Radiology, University Medical Center of the Johannes Gutenberg-University, Mainz, Germany; German Centre for Cardiovascular Research, Partner site Rhin

Purpose: To assess the feasibility and accuracy of synthetic hematocrit (Hct)-based myocardial extracellular volume (ECV) quantification using photon-counting detector (PCD)-CT late enhancement (LE) imaging, with cardiac MRI as the reference standard.

Methods: In this post-hoc analysis of a prospective study, patients underwent same-day cardiac MRI and PCD-CT LE imaging. MRI-based ECV (ECV) was computed using T1 mapping sequences before and after contrast administration.

View Article and Find Full Text PDF

Background: Extracellular volume (ECV) is an important marker of myocardial fibrosis. However, the prognostic role of ECV in diabetes patients is unknown. In addition, synthetic ECV without blood sampling has not been reported in diabetes cohorts.

View Article and Find Full Text PDF

Background: The calculation of conventional extracellular volume fraction (ECV) requires blood hematocrit (Hct) measurement. Based on the relationship between Hct and blood T1 relaxivity for cardiac magnetic resonance (CMR), a synthetic ECV could be estimated without a blood sampling. The aim of this study was to evaluate the correlation and agreement in the quantification of synthetic ECV and laboratory ECV from conventional Hct measurements.

View Article and Find Full Text PDF